NCA1-P325 NCA1-P800 NCA1-P1000 CB 1 1/4 1 1/2 2 CD 3/4 1 1 3/8 DD 17/32 21/32 21/32 E 3 1/2 4 1/2 5 F 5/8 3/4 7/8 FL 1 7/8 2 1/4 3 LR 1 1/4 1 1/2 2 1/8 M 3/4 1 1 3/8 MR 7/8 1 1/4 1 5/8 R 2.56 3.25 3.81 Weight (lbs) 3.11 5.80 10.42 Note: Pivot pin is not included Clevis Bracket CB CW CW CD MR BA E LR DD AA M F E FL Dimensions Part No.
Note 4) Window comparator mode Since hysteresis is 3 digits, separate P1 and P2 by 7 digits or more. 1 digit is the minimum setting unit (refer to the table above). 21 Series PFW How to order PFW5 20 03 Remote Type Sensor Unit Wiring specification Flow rate range Nil N 3m lead wire with connector Without lead wire 0.5 to 4l/min 2 to 16l/min 5 to 40l/min 04 20 40 Port size Thread type Size
Accessories 21 to 24 (Options) 25 Technical Data Pressure dew pointCondensed water calculation chart, Pressure dew point temperatureAtmospheric pressure dew point temperature conversion cart Note) l/min (ANR) is for reference conditions of 20C, 1 ATM and 65% relative humidity.
Dimensions Model Metric size D2 D1 H1 H2 H3 H4 H5 L1 L2 L3 Inch size TMH-05 21 8.3 8.5 15.4 7.7 9.3 6.4 6.3 3.3 11.7 TMH-06 13.1 TMH-07 26.5 10.6 11 20 10 11 7.2 7.1 4.3 13.5 10 TMH-08 TMH-09 15.5 TMH-10 18.5 34 14.6 14.2 28 14 14 9.6 9.5 4.3 TMH-11 18.8 5
DC (+) 1 NC 2 Flow direction DC () 3 OUT 4 8 Digital Flow Switch for Water Series PFW How to order 20 03 27 PFW7 Flow rate range 0.5 to 4l/min 2 to 16l/min 5 to 40l/min 04 20 40 Wiring specifications 1l/min=0.0353SCFM 3m lead wire with connector Without lead wire Nil N Thread type Rc NPT G Nil N F Output specifications 27 67 NPN (2 outputs) PNP (2 outputs) Piping port size 03 04 06 3/8 1
Left IN1(P) Piping VHS500-06 VHS501-06 VHS400-04 VHS401-04 VHS400-03 VHS401-03 VHS400-02 VHS401-02 Right IN1(P) 3 4 1 2 3 8 1 4 Port size Effective area (mm2)(CV) Weight (kg) 93(5.22) 57(3.20) 35(1.97) 21(1.18) 105(5.90) 76(4.27) 54(3.03) 35(1.97) 0.29 1(P)2(A) 2(A)3(R) 0.34 0.25 0.27 Left or right to the front face of the handle.
How to Order VR 12 1 1 F 06 Body size Applicable tubing outside diameter Metric sizes Inch sizes 1 1/8 standard 3.2 23 04 06 01 03 07 1/8" 5/32" 1/4" 4 6 Use 1/8" tubing for 3.2.
How to Order ZFB 100 04 IN/OUT applicable tubing O.D.
NTJ-015A NT-02 NT-04 NT-05 12 M5 x 0.8 4 8 9.2 7.8 H B 20 M8 x 1.25 5 13 15.0 12.5 32 . 40 M14 x 1.5 8 22 25.4 21.0 50 . 63 M18 x 1.5 11 27 31.2 26 Electrical Wiring Output type The output signal of the stroke reading cylinder is A/B phase difference output (open collector output) as shown in the figure below.
Bore size (mm) Part no. m d (Drill through) Cotter pin Note) l d Dd9 L H B C D CNG 3 x 18l 4 x 25l 4 x 35l Note) A cotter pin should be used together with a plain washer. 6 8 11 13 16 4 4.5 5 3 4 4 M10 x 1.25 M14 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 16.5 21 26 31 39 0.040 0.076 0.050 0.093 0.065 0.117 CD-M03 CD-M05 CD-M08 NT-03 NT-04 NT-05 NT-08 NT-10 32, 40 50, 63 80, 100 10 14 22 32 40 50
Applicable cylinder bore size (mm) 32, 40 50, 63 Applicable cylinder bore size (mm) Applicable snap ring 32, 40 50, 63 NT-04 NT-05 Part No.
Bore size d H B C D NT-03 32 M10 x 1.25 6 17 19.6 16.5 NT-04 40/45 M14 x 1.5 8 22 25.4 21 NT-05 50/56/63/67 M18 x 1.5 11 27 31.2 26 NT-08 80/85 M22 x 1.5 13 32 37.0 31 NT-10 100 M26 x 1.5 16 41 47.3 39 5
JMB Series Auto Switch Mounting Auto Switch Proper Mounting Position (Detection at stroke end) and Mounting Height
Bore size (mm) Part no. m d (Drill through) Cotter pin Note) l d Dd9 L H B C D CNG 3 x 18l 4 x 25l 4 x 35l Note) A cotter pin should be used together with a plain washer. 6 8 11 13 16 4 4.5 5 3 4 4 M10 x 1.25 M14 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 16.5 21 26 31 39 0.040 0.076 0.050 0.093 0.065 0.117 CD-M03 CD-M05 CD-M08 NT-03 NT-04 NT-05 NT-08 NT-10 32, 40 50, 63 80, 100 10 14 22 32 40 50
Mitsubishi Electric Corporation Yaskawa Electric Corporation 02 03 04 05 05 5m Cable length 2m 3m 4m 5m Applicable cables Model Manufacturer part no.
Symbol Order Made P.4.6-21 4.6-15 Micro Mist Separator with Prefilter Series AMH AMH150 to AMH850 How to Order AMH 250 03 J B Body size Options J Drain guide 1/4B female thread R IN/OUT reversal 150 1 8 250 1 4 350 3 8 450 1 2 550 3 4 650 1 850 11 2 Accessories(Options) Description None Bracket Symbol T Element service indicator B N.C.auto drain C N.O.auto drain D Note) Refer to p.4.7-7
42 0.2 0 0.021 4-5.5 through 2 x 4-9, counter bore depth 5.5 (opposite side also) 50 0.2 20.5 20 10.5H7 36 0.2 20h7 5.5 42 0.2 54 47 48 90 47 26 151 + Stroke 177 + Stroke 36 0.2 4-M6 x 1.0, effective length 9 50 0.2 29 Rod end male threads 0 0.021 M12 x 1.25 Width across flats 17 20h7 M12 x 1.25 19.8 25.4 18 8 22 20.5 8.5 55 Stud bolt part number: MT-S40 Rod end nut part number: MCN-NT-04
Applicable cylinder bore size (mm) 32, 40 50, 63 Applicable cylinder bore size (mm) Applicable Snap ring 32, 40 50, 63 NT-04 NT-05 l Part No.
Test operation . 21 5.1 Operation procedure . 21 5.2 JOG Mode . 22 5.3 Positioning Mode . 23 5.3.1 Positioning Mode . 24 5.3.2 Motor speed configuration . 25 5.3.3 Acceleration/deceleration time configuration . 26 5.3.4 Move distance Configuration and Operation . 27 6.
How to Use PneuAlpha Series Controllers Getting Started. 21 5.
Parianopoulus S.A. 9, Konstantinoupoleos Street, GR-11855 Athens Phone: 01-3426076, Fax: 01-3455578 Norway SMC Pneumatics Norway AS Vollsveien 13 C, Granfoss Nringspark N-1324 Lysaker Tel: (47) 67 12 90 20, Fax: (47) 67 12 90 21 Poland Semac Co., Ltd. PL-05-075 Wesola k/Warszaway, ul. Wspolna 1A Phone: 022-6131847, Fax: 022-613-3028 Czech SMC Czech.s.r.o.