Port Size: M01 [Body Ported Stacking (Barb Fitting:ø6/ø4, Tubing:ø3.18/ø2)], Stations: 18 Stations
Port Size: M01 [Body Ported Stacking (Barb Fitting:ø6/ø4, Tubing:ø3.18/ø2)], Stations: 7 Stations
Port Size: M01 [Body Ported Stacking (Barb Fitting:ø6/ø4, Tubing:ø3.18/ø2)], Stations: 2 Stations
Port Size: M01 [Body Ported Stacking (Barb Fitting:ø6/ø4, Tubing:ø3.18/ø2)], Stations: 3 Stations
Port Size: M01 [Body Ported Stacking (Barb Fitting:ø6/ø4, Tubing:ø3.18/ø2)], Stations: 4 Stations
Port Size: M01 [Body Ported Stacking (Barb Fitting:ø6/ø4, Tubing:ø3.18/ø2)], Stations: 5 Stations
Port Size: M01 [Body Ported Stacking (Barb Fitting:ø6/ø4, Tubing:ø3.18/ø2)], Stations: 6 Stations
Port Size: M01 [Body Ported Stacking (Barb Fitting:ø6/ø4, Tubing:ø3.18/ø2)], Stations: 8 Stations
Port Size: M01 [Body Ported Stacking (Barb Fitting:ø6/ø4, Tubing:ø3.18/ø2)], Stations: 10 Stations
Port Size: M01 [Body Ported Stacking (Barb Fitting:ø6/ø4, Tubing:ø3.18/ø2)], Stations: 11 Stations
Port Size: M01 [Body Ported Stacking (Barb Fitting:ø6/ø4, Tubing:ø3.18/ø2)], Stations: 12 Stations
Port Size: M01 [Body Ported Stacking (Barb Fitting:ø6/ø4, Tubing:ø3.18/ø2)], Stations: 16 Stations
Port Size: M01 [Body Ported Stacking (Barb Fitting:ø6/ø4, Tubing:ø3.18/ø2)], Stations: 9 Stations
12 10, 12 VCHC Controlled flow Free flow 230 100 260 390 460 660 790 920 1580 1710 Flow rate L/min (ANR) ASR ASQ Sonic conductance dm3/(sbar) 0.64 0.28 0.72 1.1 1.3 1.8 2.2 2.6 4.4 4.8 Flow Direction Symbols on Body Critical pressure ratio Controlled flow 0.2 0.25 0.3 0.25 0.25 Free flow 0.4 0.2 0.3 0.2 0.3 Meter-out type Meter-in type Note) Flow rate values are measured at 0.5 MPa and 20C
(mm) ASG32F-01 4 ASG42F-02 6, 8 ASG52F-03 6 ASG62F-04 Sealant: Special FKM Seat ring: Stainless steel 303 8 12 4, 6 8, 10 10, 12 460 790 920 1580 100 180 230 390 Flow rate (l/min (ANR)) Controlled (free) flow 7 12 14 24 1.5 2.7 3.5 6 Effective area (mm2) Applicable tubing materials Note) Flow rate is measured at 0.5 MPa and 20C.
Inch size 3/8" 5/16" 1/4" 1/4" 3/8" 5/32" 1/2" Symbol Flow rate (L/min (ANR)) Sonic conductance dm3/(sbar) Controlled flow Free flow 0.2 0.25 290 0.81 920 2.6 660 1.8 390 1.1 230 0.64 920 2.6 20 0.06 130 0.36 1390 3.9 Controlled flow Free flow Critical pressure ratio Note) Flow rate values are measured at 0.5 MPa and 20C.
size) ASV 4 6 6 10 8 4 Flow rate [L/min (ANR)] It may damage the body A or fittings. 100 130 230 290 660 920 AK Controlled flow Body A Free flow Sonic conductance [dm3/(sbar)] 0.28 0.36 0.64 0.8 1.8 2.6 VCHC Controlled flow Free flow 0.2 0.25 0.2 0.25 0.2 0.25 0.2 0.25 Caution Release from One-touch fitting Critical pressure ratio ASR ASQ Note) Flow rate values are measured at 0.5 MPa and 20C
10 12 4 JIS Symbol Tubing O.D. 1 8" 3 16" 1 4" 1 4" 5 16" 5 16" , 3 8" , 5 32" 3 16" 1 4" 5 16" 3 8" 3 8" " 1 2 Inch size 5 32" Flow rate (/min (ANR)) 260 390 660 790 920 1580 180 230 460 1710 Flow Direction Symbols on Body Controlled flow (Free flow) Meter-out type Meter-in type Effective area (mm2) 4 6 10 12 14 24 2.7 3.7 7 26 Symbol Note 1) Flow rate values are measured at 0.5 MPa and 20C
AS1001F AS2001F AS3001F AS2051F AS4001F Model 3.2, 4, 6 4 6 6 8 6 8 10, 12 10 12 Metric size Tubing O.D. 1/8" 5/32" 3/16", 1/4" 3/16" 1/4" 1/4" 5/16" 3/16" Inch size 1/4" 5/16" 3/8" 3/8" 1/2" 5/32" Flow rate (l/min(ANR) 290 460 230 100 130 420 660 920 1050 1390 Controlled flow (Free flow) 4.5 7 3.5 1.5 2 6.5 10 14 16 21 Effective area (mm2) Note) Flow rate values are measured at 0.5 MPa and 20C
Metric size 4 4 6 230 260 390 460 660 790 920 1580 1710 Flow rate (/min (ANR)) 180 Controlled flow (Free flow) Flow Direction Symbols on Body Effective area (mm2) 2.7 3.5 4 6 7 10 12 14 24 26 Meter-out type Meter-in type Note) Flow rate values are measured at 0.5 MPa and 20C.