0.25 to 0.7 MPa (Same as operating pressure) Maximum operating frequency 30 times/minute Minimum operating frequency 1 time/week Operating and ambient temperature 14 to 122F [10 to 50C] (No freezing) Ambient humidity 20 to 90%RH (No condensation) Manual override None Pilot exhaust Individual exhaust Lubrication Not required Mounting orientation Unrestricted Impact/Vibration resistance 150
Operating fluid Eliminate all solid material larger than 150 m in the fluid to avoid valve failure. Piping Caution 1. Piping to pilot port Condensation may be formed in the piping to the pilot port, due to factors such as its length. The life of the valve will be shortened if condensed moisture enters the pilot port.
Bore size/Stroke (mm) 10 25, 50, 75, 100 Cushion (Option) 15 25, 50, 75, 100, 125, 150, 175, 200 With adjusting bolt (2 pcs.) Nil 25 25, 50, 75, 100, 125, 150, 175, 200 B With shock absorber (2 pcs.) For 15 and 25, strokes up to 300 are available as made-to-order. (-XB11) BS With shock absorber (1 pc.)
BRACKETS SIZES PNAM-1 PNAM-2 PNAM-3 PNAM-4 130 A 130 80 80 30 B 30 30 30 55 C 75 45 55 YOKE MOUNT FOR GLOBE VALVES Please contact your SMC sales representative for availability.
As a general rule, use 80 to 100 mesh. Water supplied to boilers includes substances such as calcium and magnesium which generate hard scale and sludge. Since this scale and sludge can cause valve malfunction, install water softening equipment, and a steam filter (strainer) directly upstream from the valve to remove these substances. Caution 1.
Mounting: A (Both Ends Tapped), Bore Size: 63mm, Thread: Rc, Full Stroke: 175mm, First Stroke: 50mm
Mounting: A (Both Ends Tapped), Bore Size: 63mm, Thread: Rc, Full Stroke: 100mm, First Stroke: 70mm
Mounting: A (Both Ends Tapped), Bore Size: 63mm, Thread: Rc, Full Stroke: 250mm, First Stroke: 170mm
Mounting: A (Both Ends Tapped), Bore Size: 63mm, Thread: Rc, Full Stroke: 75mm, First Stroke: 70mm
Mounting: A (Both Ends Tapped), Bore Size: 63mm, Thread: Rc, Full Stroke: 25mm, First Stroke: 20mm
Mounting: A (Both Ends Tapped), Bore Size: 63mm, Thread: Rc, Full Stroke: 200mm, First Stroke: 100mm
Mounting: A (Both Ends Tapped), Bore Size: 63mm, Thread: Rc, Full Stroke: 200mm, First Stroke: 30mm
Mounting: A (Both Ends Tapped), Bore Size: 63mm, Thread: Rc, Full Stroke: 200mm, First Stroke: 20mm
Mounting: A (Both Ends Tapped), Bore Size: 63mm, Thread: Rc, Full Stroke: 125mm, First Stroke: 50mm
Mounting: A (Both Ends Tapped), Bore Size: 63mm, Thread: Rc, Full Stroke: 200mm, First Stroke: 50mm
Mounting: A (Both Ends Tapped), Bore Size: 63mm, Thread: Rc, Full Stroke: 175mm, First Stroke: 100mm
Mounting: A (Both Ends Tapped), Bore Size: 63mm, Thread: Rc, Full Stroke: 300mm, First Stroke: 100mm
Mounting: A (Both Ends Tapped), Bore Size: 63mm, Thread: Rc, Full Stroke: 250mm, First Stroke: 120mm
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 25/20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: With Intermediate Stop Function / Stroke with Adjustment, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Support bracket: