75 G 6.5 8.5 F 12.5 25 EK 4 6 ED 9.5 13 E 4H9 6H9 B 9.5 14 A 8 12 C 5.4 8.6 Model +0.030 0 +0.030 0 CYP15 CYP32 L 67 90 Z 118 155 Y 2.5 3.5 WB 17 27 WA 32 46 W 69 115 TB 18 22 TA 13 17 T 23 29 R 45 79.5 QW 48 87 N 4.5 7.5 Q 105 138 M 6 8 PB 60 100 MM M4 x 0.7 M6 x 1 PA 25 50 LW 69 115 P M5 x 0.8 Rc 1/8 LD 5.6 8.6 Model CYP15 CYP32 Note 1) These dimension drawings indicate the case of piping
Universal male elbow allows thread connection by using a socket wrench for confined space. 45 male elbow Extended male elbow The most appropriate use is when the elbow extends over a standard elbow for ease of connection/ disconnection of tubing. P. 41 KQ2K used in applications where a 45 elbow or male connector stresses the tubing.
/ 450 6.1 / 470 Max. electric absorbtion [A / W] 2.9 / 220 3.4 / 260 4.3 / 330 5.6 / 430 7.8 / 600 8.0 / 620 Fan electric absorption [A / W] 0.30 / 27 0.54 / 40 Acoustic pressure level at 1 mt [dbA] < 70 Weight [lb / Kg] 75 / 34 82 / 37 86 / 39 90 / 41 95 / 43 99 / 45 Correction factor for operating pressure changes : psig 30 44 58 72 86 100 114 128 142 156 170 184 198 212 232 factor 0.54
. -45- (4) Waveform Set the waveform data which will be displayed in the graph. Click of each Analog or Digital and set the type of waveform to be displayed. The analogue and digital waveforms that can be set with LECSS are shown below. Analogue waveform No.
Coefficient factors Inlet air temperature (oC) 5 to 25 30 35 40 45 50 55 60 65 1.42 1.15 1.00 0.71 0.62 0.50 0.40 0.33 0.21 Inlet air pressure (MPa) 0.3 0.4 0.5 0.6 0.7 to 1.6 0.71 0.75 0.82 0.89 1.00 Ambient temperature (oC) 2 to 25 30 35 40 45 1.0 0.85 0.80 0.73 0.62 Calculation example: The air flow capacity when the dew point of IDFA60 is set to 10 oC under the following conditions <
Two EPDM 75 durometer O-rings are supplied with each unit. Two O-rings are recommended in case of surface imperfections, damage to an O-ring during assembly, etc. The O-rings must be lubricated with silicone grease during assembly. This not only eases the assembly procedure, it also enhances the sealing characteristics of the O-ring, especially in vacuum applications.
, 3/8 VCW31 30 50 86 36.5 13.5 15 32 25 23 M5 8 24 59 46 57 60 54.5 48.5 101 57 68 104 1/2 22 45 90 41 11 17 36 22.5 23 M5 8 26 64.5 48 62.5 62 60 50.5 103 62.5 70 107 1/4, 3/8 VCW41 30 50 94 41 13.5 17 36 25 23 M5 8 26 66.5 48 64.5 62 62 50.5 103 64.5 70 111.5 1/2 35 60 102 41 17.5 17 36 30 28.2 M5 8 26 70 48 68 62 65.5 50.5 103 68 70 119 3/4 17-2-55 8 Series VCW Dimensions (N.O.)
& end-lock type Avdibble lor basrc iype only For alr cushion type 20, 25, 30, 35, 40,45. 50,60, 70, 75, 80, SO, 100 25, 30,35, 40. 45, 50, 60,70, 75,80, 90, 100 2 pcs. l p c Port thread type (with builtn magnet) See catalog for available * Refer to catalog Es20-53E, ES20-174A end Best Pneumatics 2004 \,blurn6 I for details Cushion or end lock Operating principle A+A. .
MPa) BP1006 2 to 60 psig (0.014 to 0.4 MPa) BP1010 5 to 100 psig (0.034 to 0.7 MPa) BP1020 15 to 200 psig (0.1 to 1.4 MPa) Operating Parameters Operating pressure Gas Proof pressure (Inlet) Burst pressure Ambient and operating temperature Cv Leak rate Connections Installation Internal volume Mass Select compatible materials of construction for the gas 15 psig (0.105 MPa) 30 psig (0.2 MPa) 45
0.1 to 1.4 MPa) BP1030 15 to 300 psig (0.1 to 2.1 MPa) BP1001 0.5 to 10 psig (0.0034 to 0.07 MPa) BP1002 1 to 30 psig (0.007 to 0.2 MPa) BP1010 5 to 100 psig (0.034 to 0.7 MPa) Operating Parameters Operating pressure Gas Proof pressure (Inlet) Burst pressure Ambient and operating temperature Cv Select compatible materials of construction for the gas 15 psig (0.105 MPa) 30 psig (0.2 MPa) 45
Metric size Inch size IN side Straight OUT side IN side Straight OUT side Mounting position Mounting position Elbow Note) Straight Elbow Note) Elbow Note) Straight Elbow Note) Fitting type Symbol Fitting type Symbol 4 6 4 6 4 6 4 6 5/321/45/321/4 5/321/4 5/321/4 06 07 08 18 19 20 25 26 27 32 33 34 56 57 58 68 69 70 75 76 77 82 83 84 Note) When the knob and the OUT piping are located on the
(Values at the initial period) No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was performed at both energized and deenergized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period) 3 position exhaust center Vibration resistance Note 3) Values in the case of high pressure type (1.5 W).
102 118 135 153 AMC320 75 120.5 140.5 2.3 15 20 30 50 123.5 24 55 2 3 5 6 8 9 Depth 8 M4 x 0.7 1 2 3 4 AMC520 102 173.5 193.5 3.2 Depth 8 20 20 30 70 176.5 , 40 70 On the type for the AMC220, an R 1/4 fitting can be attached by removing the drain cock.
See LECSC Operation Manual , section 6.4 for details. -45- 5.6 Positioning Mode in Setup Software From the Test Mode menu of the Setup Software select Positioning Mode. The Move Distance Unit Selection window opens. Click OK. (When using this function, external input signal operation will be disabled.
Changeable range output 5 V (10 V) 20 mA At the time of shipment 1 V (0 V) 4 mA Grease-free 10% 100% 105% Display 0% Application example Analog Functions Adjustment point: 75 L/min , 100 L/min output pp. 27, 28 When 5 V output is required from the flow switch at 75 L/min, use a sensor that outputs 1 to 5 V at 1 to 100 L/min. 5 V Change Output operation Key-lock function Forced output function
Speed [mm/s] 0 48 Operating humidity range [%RH] 90 or less (No condensation) Allowable external force [N] Note 8) 10 20 1 75 Motor size 56.4 Motor type Step motor (Servo/24 VDC) Electric specifications 2 100 3 150 Encoder Incremental A/B phase (800 pulse/rotation) 4 200 Rated voltage [V] 24 VDC10% 5 250 Power consumption [W] Note 3) 50 52 6 300 Standby power consumption when operating [W
Liquid seals When circulating fluid Provide a relief valve in the system so that fluid does not get into the liquid seal circuit. 32 (11/4) 40 (11/2) 25 (1) 50 (2) Nominal dia. mm (inch) 4.0 6.0 8.0 12.0 Tightening torque Nm TLM TILM For fittings of 65A or larger, tighten the fittings by a further 1/8 rotation (45) with a belt wrench after tightening by hand.
31 0.9 0.5 0.25 0.15 55 35 0.9 0.5 0.25 0.15 75 41 1.4 0.7 0.35 0.2 25 16 Max. operating pressure (MPa) Compatible with the Food Sanitation Law Compatible with the test conforming to the Food Sanitation Law based on the 370th notice given by the Ministry of Health and Welfare in 1959.
(Default settings) Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was performed in both energized and de-energized states in the axial direction and at right angles to the main valve and armature.
+3.00 to +20.90 mA 300 to 2090 +3.10 to +21.00 mA 310 to 2100 45 EX## OMS1015-A Parameter setting via Manufacture specific Object The EX600 parameters can be set using manufacture specific object.