The station address is set using the rotary switches S1 and S2. (1) Settings of the Rotary Switches S1 and S2 Set the station address using the rotary switches S1 and S2.

Do not drop, or apply excessive impact (980m/s2) while handing. Although the body of the sensor may not be damaged, the internal parts of the sensor could be damaged and lead to a malfunction. 2. The tensile strength of the cord is 49N. Applying a greater pulling force on it can cause a malfunction. When handling, hold the body of the sensor do not dangle it from the cord. 3.

Do not drop, bump, or apply excessive impact (100 m/s2) while handling. Although the body of the controller case may not be damaged, the inside of the controller could be damaged and cause malfunction. 2. The tensile strength of the power supply/output connection cable is 50 N; that of the pressure sensor lead wire with connector is 25 N.

amplitude in X, Y, Z directions for 2 hours each Vibration resistance 980 m/s2 in X, Y, Z directions 3 times each (Non energized) Impact resistance Temperature characteristics 2%F.S. or less (Based on 25C: Operating temperature range) Standard Compliant with CE Marking and UL/CSA (UL508) standards Wetted material Fitting: C3602 (electroless nickel plated), Sensor port: PBT, Sensor pressure

Do not drop, bump, or apply excessive impact (100 m/s2) while handling. Although the body of the controller case may not be damaged, the inside of the controller could be damaged and cause malfunction. 2. The tensile strength of the power supply/output connection cable is 50 N; that of the pressure sensor lead wire with connector is 25 N.

Do not drop, or apply excessive impact (980 m/s2) while handing. Although the body of the sensor may not be damaged, the internal parts of the sensor could be damaged and lead to a malfunction. 2. The tensile strength of the cord is 49 N. Applying a greater pulling force on it can cause a malfunction. When handling, hold the body of the sensor do not dangle it from the cord. 3.

Note 4) (ft/s2) 30/150 (9/150ft/s2) Rated voltage 24VDC, 12VDC, 100VAC, 110VAC, 200VAC, 220VAC (50/60Hz) Allowable voltage fluctuation % 10% of rated voltage Coil insulation type Class B Enclosure Note 5) Dust proof (equivalent to IP40) Power consumption W Note 3) 2.5 (VDW10), 3 (VDW20/30) Note 1) Consult SMC when used under conditions which may cause condensation on the exterior of the

Accuracy: Basic Type, Size: 63, Motor Type: T7 (200W Output, Absolute Encoder), Lead, mm: H (Size 40: 24mm, Size 63: 30mm, Size 100: 50mm), Stroke: 300mm, Motor Option: B (Lock)

Size: 25, Bearing Type: M (Sliding Bearing), Motor Mounting Position: D (In-line), Motor Type: T6 (AC Servo Motor, Absolute Encoder, Output 100W), Lead: A (LEY25 12mm; LEY32 16mm; LEY32 Top Mount 20mm), Stroke: 300mm, Motor Option: B (with Lock)

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Size: 25, AC Servo Motor: 100W Output, Absolute Encoder, Lead Screw: Size 25: 12mm, Size 32: 16mm, Size 40: 20mm, Stroke: 300mm, Motor Option: w/Lock, Actuator Cable: -, Actuator Cable Length: -, Controller: -, I/O Connector: -

Size: 25, AC Servo Motor: 100W Output, Absolute Encoder, Lead Screw: Size 25: 6mm, Size 32: 8mm, Size 40: 10mm, Stroke: 300mm, Motor Option: w/Lock, Actuator Cable: -, Actuator Cable Length: -, Controller: -, I/O Connector: -

Size: 32, AC Servo Motor: 200W Output, Absolute Encoder, Lead Screw: Size 25: 6mm, Size 32: 8mm, Size 40: 10mm, Stroke: 300mm, Motor Option: w/Lock, Actuator Cable: -, Actuator Cable Length: -, Controller: -, I/O Connector: -

Size: 32, Motor Mounting: In-line Type, Motor Type: S7 [AC Servo Motor, (Absolute Encoder), Output 200W], Lead: C [LEY25, 3mm; LEY32, 4(5)mm], Stroke: 300mm, Motor Option: w/Lock, Rod End: -, Mounting: -, Actuator Cable Type: -, Cable Length: -, Controller Type: -, I/O Connector: -