SMC Corporation of America
Elite Part Number Search
Search Results "LEFG40-S-400"

Rotations per Second Distance of movement per second Distance of movement per rotation Rotation Speed (rpm) = Speed (mm/s) Lead (mm) }60 (S) = {500 (mm/s) 20 (mm) }60 (s) =1500 (rpm) -38- 6.6.3 Acceleration/deceleration Time Configuration < Acceleration/deceleration Time Configuration> Acceleration/deceleration time (ms) configuration: The acceleration/deceleration time sets the amount

(2 s or 5 s can be selected) 13 Pressure 0.1 s (Variable at 0 to 30 s/0.01 s step) Temp. 1 s Protection IP65 Environmental Withstand voltage 1000 V AC for 1 minute between terminals and housing resistance Insulation resistance 50 M between terminals and housing (with 500 VDC megger) Operating temperature range Operation: 0 to 50 oC, Storage: -10 to 60 oC (No condensation or freezing) Operating

When ordering the double clevis, the clevis pin and the cotter pin (2 pcs.) are attached. 1.10-2 Air Cylinder/Standard Series CS1 Specifications Style Lube, Non-lube Air-hydro Fluid Air Turbine oil 1.57MPa Proof pressure 0.97MPa Max. operating pressure 0.05MPa 0.06MPa Min. operating pressure 50 to 500 mm/s 0.5to 200 mm/s Piston speed With Without Cushion CJ1 Ambient and fluid temperature

Contents Applied part Grease pack part no. 8 12 16 20 25 GR-S-005 (5 g) GR-S-010 (10 g) GR-S-020 (20 g) GR-S-050 (50 g) MXW8-PS MXW12-PS MXW16-PS MXW20-PS MXW25-PS Guide Set of nos. above !9, @0, @1 DGR-L-005 (5 g) GR-L-010 (10 g) GR-L-020 (20 g) GR-L-050 (50 g) Cylinder -X Seal kit includes !9, @0, @1, Order the seal kit, based on each bore size.

0.5 s, 0.15 s, 1.0 s, 2.0 s or 5.0 s Hysteresis 4 Variable Protection Short circuit protection Delay time 5 3.4 ms or less Variable at 0 to 60 s/0.01 step -93No.PF-OMZ0002-A Model PF2MC7501 PF2MC7102 PF2MC7202 Voltage output: 1 to 5 VDC, 0 to 10 VDC (only when the power supply voltage is 24 VDC) Output type Analogue output 6 Current output: 4 to 20 mA (Refer to analogue output graph) Voltage

0.5 s, 0.15 s, 1.0 s, 2.0 s or 5.0 s Hysteresis 4 Variable Protection Short circuit protection Delay time 5 3.4 ms or less Variable at 0 to 60 s/0.01 step -89No.PF-OMY0002 Model PFMC7501 PFMC7102 PFMC7202 Voltage output: 1 to 5 VDC, 0 to 10 VDC (only when the power supply voltage is 24 VDC) Output type Analogue output 6 Current output: 4 to 20 mA (Refer to analogue output graph) Voltage

The value of the effective area S, like that of sonic conductance C, expresses the ease of flow. (3) Formula for flow rate When P2 + 0.1 0.5, choked flow P1 + 0.1 293 Q = 120 x S (P1 + 0.1) (3) 273 + t When P2 + 0.1 > 0.5, subsonic flow P1 + 0.1 293 Q = 240 x S (P2 + 0.1) (P1 P2) (4) 273 + t Conversion with sonic conductance C: S = 5.0 x C(5) Q : Air flow rate [dm3/min (ANR)], dm3

, 450, 500 C95 40 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 50 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 CA1 63 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 CS1 80 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 100 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500

/s) 50 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 C85 -XC3 Special port location 63 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 -XC4 With heavy duty scraper 80 1400 C95 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Heat resistant cylinder (110 C) -XC5 100 1500 25, 50, 75, 100, 125, 150, 175

Standard Stroke DMaximum manufacturable stroke Bore size (mm) -X Standard stroke (mm) 20700 32 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 800 40 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 Data 1000 50 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 1000 63 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500

200 VXB215 B E(H) 100 300 400 500 600 200 VXB215 C F(H) 100 300 400 500 600 700 800 200 Flow rate Q [kg/h] How to read the graph The sonic range pressure to generate a flow rate of 300 kg/h is P1 0.3 MPa for the VXB215C F(H).

Ball screw shaft Approximately 6 months Grease pack order number (Arrange separately) GR-S-010 (10g), GR-S-020 (20g), GR-S-400 (400g) Please contact us for the Maintenance Manual. 3. It is recommended that apply the appropriate covering to the electric actuator in the environment of splashing the liquid other than water.

Auto switches are shipped together, (but not assembled). 1500 CY1S Series Magnetically Coupled Rodless Cylinder Slider Type: Slide Bearing Specifications Bore size (mm) 6 10 15 20 25 32 40 Fluid Air Proof pressure 1.05 MPa Maximum operating pressure 0.7 MPa Minimum operating pressure 0.18 MPa Ambient and fluid temperature 10 to 60C (No freezing) Piston speed 50 to 400 mm/s Cushion Rubber

For details, refer to the optional accessory (page 11). 6 HEF Series Cooling Capacity Circulating fluid: Water, Flow rate: 1 L/min Circulating fluid: Water, Flow rate: 1 L/min, When constant fan speed mode is selected 600 600 500 500 Cooling capacity [W] Cooling capacity [W] Ambient temperature 25C 400 400 Ambient temperature 25C 300 300 200 200 Ambient temperature 35C Ambient temperature

500 600 700 800 900 1000 0 0 100 200 300 400 500 600 700 800 900 1000 AU Flow rate (/min (ANR)) Flow rate (/min (ANR)) AF AR ARX21-01 ARX21-02 0.35 0.35 IR 0.30 0.30 Outlet pressure (MPa) Outlet pressure (MPa) VEX 0.25 0.25 0.20 0.20 AMR 0.15 0.15 ITV 0.10 0.10 IC 0.05 0.05 0 0 50 100 150 200 250 300 350 400 450 500 0 0 50 100 150 200 250 300 350 400 450 500 VBA Flow rate (/min (ANR)) Flow

Welded Connection Series Back Pressure Regulator for Ultra High Purity Series BP1000 For UHP gas delivery Operating pressure: 0.5 to 300 psig (0.0034 to 2.1 MPa) Body material: 316L SS secondary remelt Hastelloy internals available for corrosion resistance How to Order Port Number q w e BP10 01 2PW FV4 FV4 S Bonnet option Operating pressure Code Bonnet Standard Panel Installation 3) Code

Reduced outgassing Resin materials eliminated Laser marking is employed for the model designation. o u d t g e 2 a c s u s d i Reduction of outgassing due to surface treatment e n o u d t g R e g a 1 c s u s d i e n R g All the external parts (made of aluminum alloy) such as the body and slide table are electroless nickel plated.

W: Weight (kg) F: Load (N) FE: Load equivalent to impact (N) a: Average speed (mm/s) M: Static moment (Nm) : Collision speed (mm/s) L1: Distance to center of load gravity (m) ME: Dynamic moment (Nm) g: Gravitational acceleration (9.8m/s2) 1.4 100 =1.4 a(mm/s) FE= agW (4) 1 3 ME= FEL1=0.05aWL1(Nm) Note 4) Average load ratio (This is for averaging Max. load moment when stopper collides in case

500 100 200 300 400 600 500 100 200 300 400 600 Load (N) Load (N) Load (N) 8-7-5 6 Long Stroke Slide Table Series MXW 8, 12, 16, 20, 25 How to Order MXW 16 100 B M9N S Number of auto switches Nil S n 2 pcs. 1 pc. n pcs.