SMC Corporation of America
Elite Part Number Search
Search Results "ISE77G-02-L2-SB"

Stations L1 L2 2 stations 33.5 27.5 11 128 122 12 138.5 132.5 13 149 143 14 159.5 153.5 15 170 164 16 180.5 174.5 17 191 185 18 201.5 195.5 19 212 206 20 stations 222.5 216.5 3 44 38 4 54.5 48.5 5 65 59 6 75.5 69.5 7 86 80 8 96.5 90.5 9 107 101 10 117.5 111.5 645 Series 10-V100 Specific Product Precautions 1 Be sure to read before handling.

Body size Metric size Inch size 3 4 5 6 1/8 1/4 3/8 1/2 07 09 11 13 06 08 10 12 6mm 8mm 10mm 12mm 1/4 5/16 3/8 1/2 Thread size Universal type 01 02 03 04 1/8 1/4 3/8 1/2 With One-touch fitting Uni-fit thread form Dimensions Models TUBE O.D. d L3 Applicable tubing O.D.

Dimensions L5 D4 Applicable tubing O.D. d H (Width across flats) A L4 D1 L3 D3 L1 M D2 T L2 [mm] Model T H D1 D2 D3 D4 L1 L2 L3 L4 L5 A M Weight [g] AS221F-G01-06W2D G1/8 12 13.2 14.2 14 7.2 23 31 17.6 39.2 1.2 34.7 17 26 AS221F-G01-08W2D 15.2 25.3 32.4 18.5 28 AS221F-G01-10W2D 18.5 32.1 39.2 21 30 AS221F-G02-06W2D G1/4 17 13.2 18.5 17 7.2 25.2 34.4 20.2 42.8 1.2 36.8 17 46 AS221F-G02-08W2D

L1 L2 ZFA200 Note) The left and right brackets are mounted on the air suction filter single unit. 278

Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: B (Bracket B)

Pressure Range: ISE76G (0 to 5 MPa), Piping: 02 (Rc 1/4), Orifice: T (Orifice shipped with the Product), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: B (Bracket B)

Pressure Range: ISE75G (0 to 2 MPa), Piping: N02 (NPT 1/4), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: B (Bracket B)

Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket B, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 5 MPa, Piping: Rc 1/4, Orifice: Orifice shipped with the Product, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket B, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 2 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket B, Operation Manual/Calibration Certificate: -

The following shows an example of a switching count set point with 50.000.000 cycles according to the transmission method of the upper communication. 50.000.000(dec) = 80 F0 FA 02 (hex) (little endian) 50.000.000(dec) = 02 FA F0 80 (hex) (big endian) -22No.EX-OMY0021 Output number layout / Process data The process data of this product is designed with byte array base data type, so the byte

View A PE L1 L2 L3 power supply cable Fig. 3-9 Wiring of power supply cable * Connect an over current protection to the power cable connected to the equipment to avoid hazard. 3.3 Installation HRL Series 3-16 HRX-OM-W060 Chapter 3 Transport and Setting Up 3.3.4 Contact input/output communicatin wiring Be sure to lock out and tag out the breaker of the facility power supply (the users machine

View A L1 L2 L3 PE Inlet of the power supply cable Mount for cable tie Note: Prepare a cable tie. Fasten the power cable to the mount on the base with the cable tie.

Alarm1 Water Leak Detect FLT 01 Alarm2*1 02 Alarm3 RFGT High Press FLT 03 Alarm4*1 04 Alarm5 Reservoir Low Level FLT 05 Alarm6 Reservoir Low Level WRN 06 Alarm7 Reservoir High Level WRN 07 Alarm8 Temp. Fuse Cutout FLT 08 Alarm9 Reservoir High Temp. FLT 09 Alarm10*1 10 Alarm11 Reservoir High Temp.

ZK2-OM01301 Manifold ZZK2 04 A A 1 L 00 00 (1) (2) (3) (4) (5) (6) Remains blank when no option is selected. (1) Number of stations Note 1) Symbol Stations 01 1 station 02 2 stations 10 10 stations Note 1) In the case of an ejector, for an adequate performance, the number of stations when operated simultaneously depends on the nozzle diameter.

ZK2-OM00201 Manifold ZZK2 04 A 1 L 00 00 (1) (2) (3) (4) (5) (6) Remains blank when no potion is selected. (1) Number of stations Note 1) Symbol Stations 01 1 station 02 2 stations 10 10 stations Note 1) In the case of an ejector, for an adequate performance, the number of stations when operated simultaneously depends on the nozzle diameter.

A control valve with cylinder speed control function and rapid air supply function Meter-out control ASS500 52.0 1/2, 3/4 55.0 580 ASS600 80.0 3/4, 1 90.0 950 ASS110 2.4 1/8 5.4 97 Meter-in control ASS310 16.5 1/4, 3/8 23.0 220 Specifications Air Fluid 0.7 MPa Max. operating pressure AS 5 to 60C (No freezing) Ambient and fluid temperature 0.1 to 0.5 MPa Set pressure ASP How to Order ASN 02

Rc NPT G Nil N F OUT(2) 1 IN(1) Port size Class 3 Class 2 Port size 1/8 (6A) 1/4 (8A) 3/8 (10A) 1/2 (15A) 3/4 (20A) Class 4 Symbol 01 02 03 04 06 Voltage 1 2 3 4 36 100 VAC 200 VAC 110 VAC 220 VAC 230 VAC Orifice size Please consult with SMC regarding other voltages.

Nil N F Rc NPT G OUT 1 IN Port size Symbol 01 02 03 04 06 Class 3 Class 2 Port size 1/8 (6A) 1/4 (8A) 3/8 (10A) 1/2 (15A) 3/4 (20A) Class 4 Voltage 1 2 3 4 36 100VAC 200VAC 110VAC 220VAC 230VAC Orifice size Consult SMC regarding other voltages.

PA03 02: LEC-MR-RB-032 03: LEC-MR-RB-12 Set this parameter to enable the absolute position detection system. For details, refer to "LECSN-T Operation Manual, Chapter 12.