25-MLAISE35-N-25-M (Switch body only)] Note 3 NPN output Wiring top entry ISE35-R-25-MLAISE35-R-25-M (Switch body only)] Note 3 Digital pressure switch PNP output Wiring bottom entry ISE35-N-65-MLAISE35-N-65-M (Switch body only)] Note 3 PNP output Wiring top entry ISE35-R-65-MLAISE35-R-65-M (Switch body only)] Note 3 N.C.
unit only) C V V D V None (SI unit only) E End plate exhaust C Pressure switch for vacuum 0 to 101 Individual port exhaust V V F V None (SI unit only) H V V J V None (SI unit only) P Pressure sensor 0 to 101 Analog output 1 to 5 V T 100 to 100 F Individual port exhaust For Manifold 100 to 100 High-noise reduction silencer exhaust High-noise reduction silencer exhaust H N Without pressure
"n" pcs. Slide bearing guide Cam follower guide Nil S n M C Stroke Nil Without auto switch Refer to the standard stroke table on page 2. Refer to the table below for auto switch types.
(i) 3) Set the value of the position switch (h) to "0" and (f) press and hold the set button (g) for 3 seconds. The (b) (h) 7-segment LED (f) displays "0" with a dot and the alarm LED (b) flashes. (g) 4) When the position switch (h) is set at the required (f) parameter number ("2" in this case), the 7-segment LED (f) displays the value of the position switch (h) with a dot. (h) No.
Without auto switch CG5 L N 25 S R 100 CDG5 L N 25 S 100 G5BAL R With auto switch Built-in magnet Number of auto switches 2 pcs. 1 pc. n pcs.
Without auto switch CG5 L N 25 S R 100 CDG5 L N 25 S 100 G5BAL R With auto switch Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Built-in magnet Number of auto switches 2 pcs. 1 pc. n pcs.
Temp. upper/lower 4 Fig.9-3 limit alarm occurrence 9-1 Alarm 9.2 Alarm indication Blink E R R 1 4 T h e r m o s t a t A l a r m M O D E < S h u t o f f Fig.9-1 Alarm indication in the event ERR14 arises Blink E R R 1 4 P B R a n g e M O D E < 2 . 0 C Fig.9-2 Alarm indication in the event ERR14 arises during PB range setting input Light W R N P V < 2 6 . 6 C # 1 S V 2 5 . 0 C M O D E N
peak value S16 N 0x0 to 0x1068 (0 to 4200) 8030 0x1F5E 0 R Flow bottom value S16 N 1 R Accumulated mantissa S16 N 0x0 to 0x270F (0 to 9) Accumulated mantissa x accumulated index = current accumulated flow 8040 0x1F68 2 R Accumulated index S16 N 0x0 to 0x0008 (0 to 8) -46No.PF-OMX0007-A 1: "R" means Read and "W" means Write. 2: Refer to the table below for the symbol.
A RZQ Foot Style: JAHL MI W S JAHL40, 50 Center of sphere CEP1 CE1 CE2 ML2B R C J G5-S JAHL63 to 100 Center of sphere CV MVGQ CC RB R J (mm) Maximum operating tension and compression force (N) M Allowable eccentricity U Center of sphere R Applicable bore size (mm) Model Maximum thread depth P DWeight (kg) A B C D E F K L T N J G H Nominal size Pitch -X Standard: Heavy Load Type Hydraulic
A RZQ Foot Style: JAHL MI W S JAHL40, 50 Center of sphere CEP1 CE1 CE2 ML2B R C J G5-S JAHL63 to 100 Center of sphere CV MVGQ CC RB R J (mm) Maximum operating tension and compression force (N) M Allowable eccentricity U Center of sphere R Applicable bore size (mm) Model Maximum thread depth P DWeight (kg) A B C D E F K L T N J G H Nominal size Pitch -X Standard: Heavy Load Type Hydraulic
H e a t i n g / C o o l i n g R a t i o M O D E < 2 0 0 % 8. Overload Judging Temp. Range Setting range : 0.1 to 9.9 C Min. increment : 0.1 C Indicated content : Overload judging temp. range (Ex. : 0.2 C) Function : Sets the temp. range for judgment of product overload (accompanying abnormal output alarm ERR15). O v e r l o a d J u d g i n g T e m p .
DO Without connector Do not replace V111 (G, H, L, M, W) to V115 (DIN terminal) and vice versa when replacing pilot valve assembly only. 18 Series SYJ500 Body Ported [ ] for AC Grommet (G), (H): SYJ52G H -M5 With bracket: SYJ52G H -M5-F G: Approx. 300 H: Approx. 600 (Lead wire length) 55.6 [57.8] 37 M5 x 0.8 (A port) 33.5 2-3.5 (For mounting) 30 3.5 15.5 2.5 15 11 A 18 25 + Manual override
Same surface Same surface D-A9 D-M9 D-M9W 10 note) 45 45 + 45 (n-2) D-C7 D-C80 10 50 50 + 45 (n-2) D-H7 D-H7W D-H7BAL/H7NF 60 + 45 (n-2) 10 60 D-C73C D-C80C D-H7C 65 + 50 (n-2) 10 65 D-B5/B64 D-G5/K59 D-B59W 75 + 55 (n-2) 10 75 D-B7/B80 D-G79/K79 50 + 45 (n-2) 10 45 Note) For cylinders with 2 auto switches D-A93/M9/M9W.
x Mounting hole Pitch = 100 Mounting hole quantity n Quantity Stroke 100 2 4 200 3 6 300 4 8 A = (n 1) x pitch 400 5 10 30 500 6 12 600 7 14 LTF8 M6 bolt 3.5 2 x n x Mounting hole 6.6 or M6 Pitch = 100 Mounting hole quantity n n Quantity Quantity Stroke Stroke 100 2 4 600 7 14 200 3 6 700 8 16 A = (n 1) x pitch 36 300 4 8 800 9 18 400 5 10 900 10 20 500 6 12 1000 11 22 93 Series LTF Deflection
Slroke = 079 (20mrt) w h Boot Mr limelers i. Parenlneses CPA1 BN do Boot with Boot' BORE D E G'GB J K M MM N P H z.
Slroke = 079 (20mrt) w h Boot Mr limelers i. Parenlneses CPA1 BN do Boot with Boot' BORE D E G'GB J K M MM N P H z.
pcs. + 3.5 x (n pcs. 1) 24 or more 31 0 0.4 4 x R2 or less Panel mount example
8 x L counter bore J J A + Stroke M M Rod end male thread CHKDB20, 25 CHKDB32 to 100 Water resistant type S N g C B + Stroke h + Stroke A + Stroke Rod end male thread (mm) B C D E F G H J K L M P Q R A Bore size (mm) 20 51 43 8 12 10 M8 x 1.25 10 6 30 5.5 9.5 depth 5.4 43 1/8 16.5 6 25 53 45 8 14 12 M10 x 1.5 12 6 36 5.5 9.5 depth 5.4 49 1/8 17 8 32 61 51 10 18 14 M12 x 1.75 15 7 47 6.6
N 32 100 H7BW Number of auto switches Bearing type Nil S n 2 pcs. 1 pc. n pcs.
Thus, F= 5 x 0.05 x 9.8 = 2.5 (N) 1. Calculation of applied lateral load F F = N m g (N) = 0.2 x 10 x 0.1 x 9.8 = 2.1 (N) CC 70 Lateral load F (N) RB 60 0.4 MPa 50 J 40 2. Confirmation of allowable lateral load From the graph, the allowable lateral load at L = 50 mm and P = 0.4 MPa is 18 N. Because 2.1 N < 18 N, it is applicable. 30 20 D2.