SMC Corporation of America
Elite Part Number Search
Search Results "HRSH150-A-20-AS"

2 62 3-8H10 depth 20 Stroke + 32 92 Body mounting reference plane 90 (T-slot pitch) 3.3 20 5.8 67 1.7 5.3 62 T-slot 1 dimensions (Switch groove) 8-M6 x 1 thread depth 20 92 58 (88) 10 10 Stroke + 216 11.5 45 9.4 4.5 10 18 The body mounting reference plane should be used as a standard when mounting onto equipment.

Connect the skip valve to the A port side of a stop valve as in the case of the speed control valve.

It can be used alone as a tank. The pressure vessel law is different from country to country, so as an air tank suitable to a country needs to be confirmed.

It contains a heavy duty spring which is dangerous and there is also a danger of reducing the locking performance. 4. Never remove the pivot seal and disassemble the internal unit. As for 20 to 32, a 12 silver seal (pivot seal) is labeled on the one surface of the lock body (on the surface opposite from the unlocking port).

When a load, such as a relay or solenoid, which generates surge is directly driven, use a type of switch with a built-in surge absorbing element. 8.

When a load, such as a relay or solenoid, which generates surge is directly driven, use a type of switch with a built-in surge absorbing element. 8.

Use it when you want to remove water but air as dry as that from an air dryer is not necessary, or when a power supply for an air dryer is not available, etc.

The purpose of an air cushion is not to reduce the speed of a piston as it nears the stroke end.

The purpose of an air cushion is not to reduce the speed of a piston as it nears the stroke end.

(Order HD1 (Heavy Duty Air Cylinders)) Fourth, Order a Self Aligning Rod Coupler. Rod Couplers Part # Rod Thread DMA-312 5 16-24 DMA-375 38-24 DMA-437 7 16-20 DMA-500 12-20 The Table on the right shows the Rod Couplers that offers. The thread shown is a male / female thread as the coupler has both a male and female end.

(Order HD1 (Heavy Duty Air Cylinders)) Fourth, Order a Self Aligning Rod Coupler. Rod Couplers Part # Rod Thread DMA-312 5 16-24 DMA-375 38-24 DMA-437 7 16-20 DMA-500 12-20 The Table on the right shows the Rod Couplers that offers. The thread shown is a male / female thread as the coupler has both a male and female end.

Note 3) Under a 5 mA condition, the indicating light visibility becomes low and at a 2.5 mA condition, it may be unreadable. However, as long as the contact ouput is over a 1 mA condition, there will be no problem.

Connection with tools such as an air driver is also possible. Note) Ensure the TKS does not shake or vibrate. Window Air driver, etc. 4. Pull the TKS off of the tubing to complete stripping. The tube can be attached as it is to a FR One-touch fitting. Operation Caution 1. When using a tool such as as air driver, use a pushstart type which rotates after the tubing is inserted. 2.

40 80 70 60 50 40 30 30 20 Point of application L mm 80 60 40 120 100 Point of application L mm 4 Escapements Series MIW/MIS 12, 20 How to Order Finger options Nil: Basic type (Standard type) 1: Tapped on upper and lower faces 2: Tapped on all faces (5 surfaces including end surface) Stroke 12 20 12 20 12mm 20mm MIW only accommodates a stroke of the same length as the cylinder diameter.

Use them as a guide. Resistance load: Tf A load that is affected by external forces such as friction or gravity Since the object is to move the load, and speed adjustment is necessary, allow an extra margin of 3 to 5 times in the effective torque.

The direction of the weight must be vertically downward in relation to the surface on which the workpiece is mounted, as shown in the diagram on the right. eDo not apply a load that involves shocks such as those caused by pounding (particularly with the ball bushing style). rIf this weight is applied, the deflection of the guide shaft will also have a large value. 12 60 350 16 70 500 20 125

tubing O.D. d D3 D1 AS-F TMH L4 L3 M ASD AS D2 AS-FE L5 A KE AS-FG AS-FG H T AS-FP L1 L2 AS-FM AS-D Metric Size [mm] AS-T Model d T H D1 D2 D3 L1 L2 L3 L4 L5 Note 1) A Note 2) M Weight [g] Unlocked Locked Unlocked Locked AS13l1FG-M5-23A 3.2 ASP 7.2 11.6 19.7 AS13l1FG-U10/32-23A AS13l1FG-M5-04A 4 8.2 17.5 33.8 ASN M5 x 0.8 10/32UNF 8 20.1 AS13l1FG-U10/32-04A AS13l1FG-M5-06A 6 10.4 21.2 20.4

1) (Station n) 48.5 [55.5] + + + + + 48.5 [55.5] 33.1 + + + + + 20 A A 33.1 20 5.1 (Pitch) P=10.5 18.5 One-touch fitting (A port) Applicable tubing O.D.: 4, 5/32" A A 5.1 (Pitch) P=10.5 18.5 M5 x 0.8 (A port) Station n L1 L2 3 58 50 Station 20 236.5 228.5 6 89.5 81.5 8 110.5 102.5 10 131.5 123.5 Station 2 47.5 39.5 4 68.5 60.5 5 79 71 7 100 92 9 121 113 11 142 134 12 152.5 144.5 13 163 155

Recommended Parameter Values [LEF] LEFS25 LEFS32 LEFS40 Series Lead symbol H A B H A B H A B Lead 20 12 6 24 16 8 30 20 10 Parameter *1,*2 Para. Initial value Recommended value No.

With air cushion 2 x M5 x 0.8 Relief port RA GA WA RA GA WA Cushion valve (Width across flats WH) Cushion valve (Width across flats WH) 10 10 20 20 ZZ + 2 Stroke S + Stroke (mm) A AL Bore size Stroke range Standard Long B1 C D E F GA H H1 I J K KA MM NA P RA S 1 2 ZZ 20 20 20 13 14 14 20 20 2 2 2 2 2 2 3 3 12 14 18 25 30 32 40 50 8 10 12 16 20 20 25 30 14 16.5 20 26 32 38 50 60 13 17 17 19