Cooling Capacity: 300 (CH1: 26 kW; CH2: 1 kW), Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: CH2 w/Electric Conductivity Control, Pump Option: T2 (20 L/min, CH2 Optical Head)
Cooling Capacity: 100 (CH1: 9 kW; CH2: 1 kW), Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (60 Hz)], DI Option: DI (CH1, CH2 w/Electric Conductivity Control)
Cooling Capacity: 200 (CH1: 19 kW; CH2: 1 kW), Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: DI (CH1, CH2 w/Electric Conductivity Control)
Cooling Capacity: 100 (CH1: 9 kW; CH2: 1 kW), Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: DI (CH1, CH2 w/Electric Conductivity Control), Pump Option: T2 (20 L/min, CH2 Optical Head)
Cooling Capacity: 012 [1000/1200 W (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: T (High-pressure Pump Mounted)
Cooling Capacity: 012 [1000/1200 W (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: None
Cooling Capacity: 018 [1600/1800 W (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: T (High-pressure Pump Mounted)
Cooling Capacity: 018 [1600/1800 W (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: None
Cooling Capacity: 018 [1600/1800 W (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: DM (w/Electric Conductivity Control Function, Applicable to DI Water Piping)
Cooling Capacity: 012 [1000/1200 W (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: MT (M + T)
Cooling Capacity: 012 [1000/1200 W (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: T (High-pressure Pump Mounted), Option 2: Z (No Flow Sensor, Water Leakage Sensor, Particle Filter, Bypass Valve or Retaining Clip)
Cooling Capacity: 018 [1600/1800 W (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: MT (M + T)
Cooling Capacity: 018 [1600/1800 W (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: DMT (DM + T)
Cooling Capacity: 012 [1000/1200 W (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: M (Applicabe to DI Water Piping)
Cooling Capacity: 012 [1000/1200 W (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: M (Applicabe to DI Water Piping), Option 2: Z (No Flow Sensor, Water Leakage Sensor, Particle Filter, Bypass Valve or Retaining Clip)
Cooling Capacity: 010 [770/950 W (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: DMT1 (DM + T1)
Cooling Capacity: 018 [1600/1800 W (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: DM (w/Electric Conductivity Control Function, Applicable to DI Water Piping), Option 2: Y (w/Feet, w/o Rack Mounting Brackets)
Cooling Capacity: 010 [770/950 W (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: None
Cooling Capacity: 010 [770/950 W (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: T1 (Inverter Pump Mounted)
Cooling Capacity: 018 [1600/1800 W (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: T (High-pressure Pump Mounted), Option 2: Z1 (No Flow Sensor or Retaining Clip)