SMC Corporation of America
Elite Part Number Search
Search Results "CYP32-500"

Stations L n 2 173 162.5 145.6 13.5 109 3 198 187.5 169.6 14 133 4 223 212.5 193.6 14.5 157 5 248 237.5 217.6 15 181 6 273 262.5 241.6 15.5 205 7 298 287.5 265.6 16 229 8 323 312.5 289.6 16.5 253 9 348 337.5 313.6 17 277 10 373 362.5 337.6 17.5 301 11 385.5 375 361.6 12 325 12 410.5 400 385.6 12.5 349 13 435.5 425 409.6 13 373 14 460.5 450 433.6 13.5 397 15 485.5 475 457.6 14 421 16 510.5 500

MNB CNA Maximum piston speed: 500 mm/s It can be used at 50 to 500 mm/s provided that it is within the allowable kinetic energy range. (The lock-up cylinder can operate at 50 to 200 mm/s.)

For Air 1.0 Downstream pressure of valve (P2) [MPa] Upstream pressure of valve P1z1.0 MPa 0.8 Subsonic 0.9 0.6 Critical pressure 0.8 0.7 Sonic 0.4 0.6 0.5 0.4 0.2 0.3 0.2 0.1 0 3/64 (1.2) 50 100 150 3/32 (2.4) 100 200 300 400 1/8 (3.2) 300 200 100 400 500 600 700 5/32 (4) 200 1, 000 800 400 600 7/32 (5.6) Series VXN2 250 500 7/32 (5.6) Series VXN3 500 1, 000 1, 500 2, 000 Flow rate Q [L/min

M24 x l 500 M24 x l 500 AT6C AT11C AT22C AT37C AT55C AT75C AT125C AT150C AT220C 1 2 Rc 1/2 Rc 3/4 Rc 1 Rc 1 Rc 1 1/4 Rc 1 1/4 Rc 2 Rc 2 Rc 2 Rc 110 110 110 180 180 180 260 260 Rc 3 4 Rc 1 1 2 1 2 Rc 1 2B (JIS 10kFF) 2B (JIS 10kFF) 3B (JIS 10kFF) 4B (JIS 10kFF) 4B (JIS 10kFF) 14-16-2

Rubber bumper Standard stroke: None, Long stroke: Standard equipment Mounting Through-hole/Both ends tapped common CUJ Piston speed 50 to 500 mm/s CU CQS Clean Series (Standard stroke is only available.)

Standard equipped with shock absorber -X 75 100 125 150 200 250 300 20 25 32 40 50 63 80 100 20 25 32 40 50 20Series MGC P . 8-21-6 Data Series MGG V V V V V V V V V V V V V V Guide Cylinder Guide Table Cylinder with Turntable Series MGC Long stroke Bore size (mm) Standard stroke (mm) Compact type of series MGG Lightweight, space-saving 250 300 350 400 450 500 600 700 800 900 1000 1100 1200

Standard stroke Maximum manufacturable stroke (mm) Standard stroke (mm) Bore size (mm) Suffix for stroke adjusting unit 25 32 40 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 2000 2000 2000 Nil S 2 pcs. 1 pc.

(Additional range) Relation between the sensor input and pressure display Pressure range Set value A B Fine differential pressure 0.002 0 kPa 2 kPa Vacuum pressure -0.1 0 kPa -101 kPa Compound pressure F0.1 -100 kPa 100 kPa Low pressure 0.1 0 kPa 100 kPa 0.5 0 kPa 500 kPa Positive pressure 1.0 0 MPa 1 MPa 1.6 0 MPa 1.6 MPa 2.0 0 MPa 2 MPa 5.0 0 MPa 5 MPa High pressure 10.0 0 MPa 10 MPa 20.0

Display MPa kPa Pa Kgf/cm2 bar mbar psi inHg mmHg mmH2O Fine differential pressure 2 kPa 0.002 0.001 1 0.01 0.001 0.1 Vacuum 101 kPa -0.1 0.001 0.1 0.001 0.001 0.01 0.1 1 Compound 100 kPa F0.1 0.001 0.1 0.001 0.001 0.02 0.1 1 Low pressure 100 kPa 0.1 0.001 0.1 0.001 0.001 0.01 500 kPa 0.5 0.001 1 0.01 0.01 0.1 Positive pressure 1 MPa 1 0.001 1 0.01 0.01 0.1 2 MPa 2 0.001 1 0.01 0.01 0.2

] 500 L/min (PFMB7102) The accumulated flow has exceeded the accumulated flow range.

2_P] Normal output [ 500] 500 L/min (PF3A701H) [P_2 ] Select input switch operation [1000] 1000 L/min (PF3A702H) ([F 2]) 2 [ 50] 50 L/min (PF3A701H) [H_2 ] Setting of Hysteresis [ 100] 100 L/min (PF3A702H) [dt2 ] Delay time setting [0.00] 0.00 s [CoL ] Select display colour [1SoG] Green when ON Red when OFF (OUT1) [F 3] [FiL ] Select digital filter [ 1.0] 1 second [F 5] [FnC ] ([FUnC]) Select

(Page 83) P_2(n_2) (Selection of output set value) Setting of OUT2 output set value (Hysteresis) 1022 0x03FE 0 R/W S16 500 Y Setting range Refer to "Settable range list". (Page 83) H_2 (Setting of OUT2 hysteresis) Setting of OUT2 hysteresis (Hysteresis) 1023 0x03FF 0 R/W U16 50 Y Setting range Refer to "Settable range list".

(Page 85) P_2(n_2) (Selection of output set value) Setting of OUT2 output set value (Hysteresis) 1022 0x03FE 0 R/W S16 500 Y Setting range Refer to "Settable range list". (Page 85) H_2 (Setting of OUT2 hysteresis) Setting of OUT2 hysteresis (Hysteresis) 1023 0x03FF 0 R/W U16 50 Y Setting range Refer to "Settable range list".

Max. 2s 2s 1s 1s Min. 0.5s 0.5s 0.2s 0.2s 0.1s 0.1s 0.05s 0.05s 0.02s 0.02s 0.01s 0.01s 6000 100 125 200 300 400 500 700 1000 1500 2000 30004000 10 100 125 200 300 400 500 600700 1000 1500 2000 3000 4000 600 5000 7000 Current (% for breaker capacity) Current (% for breaker capacity) For HRS100-A/W-20-B For HRS150-A/W-20-B HRS100-A/W-40, HRS150-A/W-40 4h 2h 1h 30min 20min 14min 10min 6min

By default: 500 hour Usage time Displays the usage time of a dustproof filter. 7 Dustproof 1 to 9hour The Maintenance reminder is issued if the usage time has reached the hours specified by the user.

Filter 3 By default: 500 hour CH2 Operating time Displays the CH2 pump mechanical seal used time Mechanical 9 8000 hour The recommended replacement cycle of the mechanical seal is displayed.

(+)LINE(-) -10No.PS-OMG0005CN-E (A/D ) () 20 2030 -11No.PS-OMG0005CN-E PSE560 PSE561 PSE563 PSE564 01 MPa 0-101 kPa -100100 kPa 0500 kPa -0.10 MPa 10.10 kPa -500 kPa 1.5MPa 500 kPa 500 kPa 750 kPa PSE56PSE56--28 SUS316L DC1224 V10-10 10 mA DC15 V 420 mA () DC0.61 V () () 500 (24 V ) 100 (12 V ) 1 k (25 ) 1F.S.() 3F.S.() 0.5F.S. 0.2F.S. 0.3F.S.

Conversion cable 21 No.JXC-OMY0002-A 2 Connection with a PC Controller PC 120.3 120.3 mm mm 200 200 mm/s mm/s Communication cable USB cable (A-miniB type connector) 100 500 100 500 1 1 200 1000 200 1000 2 2 50 200 50 200 3 3 SI When using the LEC-W2, it is necessary to connect a conversion unit (P5062-5) to the communication cable.

100 500 1 1 200 1000 200 1000 2 2 50 200 50 200 3 3 SI When using the LEC-W2A-C, it is necessary to connect a conversion unit (P5062-5) to the communication cable.

Axis mode (mm/s) (mm) Selection (mm) (mm) 2) 2) (mm/s (mm/s (mm) 0 ABS 100 20.00 1000 1000 0 0 0 100 18.00 22.50 0.5 1 ABS 50 10.00 1000 1000 70 60 5 100 6.0 12.0 1.5 63 ABS 20 5.00 500 500 0 0 0 100 3.0 8.0 1.2 -41- () () (TB) No. Step No. 063 No. TB PLC 0 No.