SMC Corporation of America
Elite Part Number Search
Search Results "CNA2B80-800-D"

Magnet: None, Mounting: B (Basic), Tube Material: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 300mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Made to Order: XC35 (w/Coil Scrapper)

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

The signal has to be converted by an A/D converter for pressure display or switch output. Current output signal is a current signal in the range of 4 to 20 [mA]. The signal is transformed into a voltage signal before being converted by a A/D converter for pressure display or switch output.

BBA1: D-A5/A6/F5/J5 types *"D-F5BAL" switch is set on the cylinder with the screws above when shipped. When a switch only is shipped, "BBA1" screws are attached.

BBA1: D-A5/A6/F5/J5 types *"D-F5BAL" switch is set on the cylinder with the screws above when shipped. When a switch only is shipped, "BBA1" screws are attached.

DC: DL (With indicator light) Option Grommet G D DIN terminal 5 Base mounted 0 Manifold 4 Coil rated voltage 1 100 VAC, 50/60 Hz 2 200 VAC, 50/60 Hz 5 9 24 VDC Construction Other Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Body ported De-energized Base mounted

P1 Control Circuit Power Supply Connector: CNP2 Accessory P2 Terminal name Function Details P C D Connect between P and D. (Connected at time of shipping.) If regeneration option is required for Model Selection, connect to this P Regeneration option C terminal. D Connect the control circuit power supply.

Auto Switch Proper Mounting Position Applicable Cylinders: MK2 Series D-M9 D-M9V D-M9W D-M9WV D-M9AL D-M9AVL D-A72/A7H D-A80H/A73C D-A80C/F7/F79F D-J79/F7V/J79C D-F7BA/F7W D-J79W/F7WV A Auto switch model D-A79W D-F7NTL D-A9 D-A9V D-A73 D-A80 D-P4DWL B B A A B A B A B B B A A Bore size 12 7 34 29 4 26 8 4 6.5 30 26 28.5 20 14 9 34.5 30 6 27 10 6 8.5 31 27 29.5 25 15.5 10.5 38 33.5 7.5

Blanking plug KQ2PDimensions 23 04 06 A L D Model Applicable fittings size d It is inserted into an unused cylinder port and SUP/EXH ports.

(Only for units compatible with M12 PROFIBUS DP , CC-Link communication connectors) SY3000/5000 VQC1000/2000/4000 S0700 SV1000/2000/3000 D D D D Note) The SY3000/5000, VQC1000/2000/4000, and S0700 are not yet UL-compatible.

For details, refer to page 443. 413 CHA Series How to Mount and Move the Auto Switch Solid state D-F59, D-F5P D-J59, D-F5BA D-F59W, D-F5PW, D-J59W D-F59F, D-F5NT Reed D-A53, D-A54, D-A56, D-A64, D-A67 D-A59W Solid state D-M9N(V), D-M9P(V), D-M9B(V) D-M9NW(V), D-M9PW(V), D-M9BW(V) D-M9NA(V), D-M9PA(V), D-M9BA(V) Auto switch mounting screw

(Not mountable after the time of shipment) RHC MK(2) Auto Switch Mounting Height RS Q G D-B5/B64 D-B59W D-G5 D-K59 D-G5NTL D-G5W D-K59W D-G59F D-F5 D-J5 D-F5W D-J59W D-F59F D-F5NTL Auto switch model D-Z7/Z80 D-Y59 D-Y7P D-Y7W D-Y69 D-Y7PV D-Y7lWV D-A44 D-A44C D-A3 D-G39 D-K39 D-A3C D-G39C D-K39C D-A5 D-A6 D-A59W RS H A RZQ Bore size (mm) Hs Ht Hs Hs Hs Ht Hs Hs Ht Hs Ht Hs Hw Hs Hw MI W S

(Not mountable after the time of shipment) Auto Switch Mounting Height D-B5/B64 D-B59W D-G5 D-K59 D-G5NTL D-G5W D-K59W D-G59F D-F5 D-J5 D-F5W D-J59W D-F59F D-F5NTL Auto switch model D-Z7/Z80 D-Y59 D-Y7P D-Y7W D-A3C D-G39C D-K39C D-A44 D-A44C D-A3 D-G39 D-K39 D-Y69 D-Y7PV D-Y7WV D-A5 D-A6 D-A59W Bore size (mm) Hs Hs Ht Hs Ht Hs Ht Hs Hs Ht Hs Hw Hs Hw Hs 40 38 40 31 38.5 31 30.5 30 72.5 73

D-M9NV D-M9N D-M9B D-M9BV D-M9PV D-M9P Auto switch part no.