VV5Q11 (L4) (L3) L2 (5.25) (12) 13 27 28 L1 Indicator light 63.5 23.5 10.5 (n-1) x 10.5 1.5 Manual override A A A B A B A B A B A FG + + 0V 24V SMC S E R I A L U N I T MODEL SC (SI No.EX120-STA1) 2 93.5 66 64 ERR T/R RUN (35) (5.5) 0 1 DIP SW. 4 x M4 mounting hole 61.5 4.5 Drawing shows a SC case.
Contents Contents 20 25 32 40 50 63 80 100 MGP63-B-PS MGP80-B-PS MGP100-B-PS MGP20-B-PS MGP25-B-PS MGP32-B-PS MGP40-B-PS MGP50-B-PS Kits include items 21, 22, 23, 24, 32, 33, 41 and 42 from the table above. Kits include items 21, 22, 23, 24, 32, 33, 41 and 42 from the table above. Items 32 and 33 are not included for bores sizes 80 and 100.
LS -t Stroke flats KA '\ _I.lY lIC x=N =-_ D_J,!~~~,-,--:N =FxTv1:::, _;d", .. I >s-, _",L c x ,,--,I Width across flats KA "' t11 ,.,.. II + t + 2 x strokes with rod boot 011 one side} ~ . B ZZ -t2 xstrokes.1 12 + 2X!
141.1 99.2 99.2 19 42.9 (Lead wire length) 19 42.9 Polarity indication 13.6 13.6 A B A B B A A COM B + A B A B A B A Manual override (Push and turn for locking type) 42 31.4 Manual override (Press and turn for the locking type) 42 31.4 84.9 B: Green A: Orange 2-4.2 84.9 B: Green A: Orange 2-4.2 2-One-touch fittings (Mounting holes for manifold) (A, B port) (A, B port) 2-One-touch fittings
6 t u i o !7 !9 !8 @0 u i !8 !9 !6 @0 o 20 32, 40, 50 w @2 @1 !5 !4 t i i u !8 !9 w @2 u !5 !4 y q !9 @0 @1 t e @0 !6 !6 !8 o y q e o Double acting with spring loaded (B) !0 20, 32, 40, 50 12, 16 !0 Single acting / spring extend (T) !1 !2 !0 12, 16 20, 32, 40, 50 !0 !3 Component Parts No.
6 8 10 10 12 14 14 16 20 24 26 n 2 3 4 4 5 6 6 7 9 11 12 D 340 510 680 680 850 1020 1020 1190 1530 1870 2040 E LEFB25;T-300; LEFB25;T-500; LEFB25;T-600; LEFB25;T-700; LEFB25;T-800; LEFB25;T-900; LEFB25;T-1000; LEFB25;T-1200; LEFB25;T-1500; LEFB25;T-1800; LEFB25;T-2000; B 306 506 606 706 806 906 1006 1206 1506 1806 2006 Note 1) When mounting the electric actuator using the body mounting reference
NPTF PodLocallon P A B EA EB sP0101/sP01r r 1/B s S sPot0zsP0112 S sP01m/sP0113 1/6 9B S/B S/B s/B S/B sPoto4/sP0114 1/. B B B sPor05/sP011s la S S S Electrictl Conncllons: Class 1 suFplates provide access of alectri(El solenoid leads from the vatue bass inlothe conduitcavitywithinthe sub-platediecasting.
T1) terminal block) -1A: +COM -1NA: COM SX3000-64-1A 1NA SX5000-64-1A 1NA t-1 SX3000-64-26 2A 2NA SX5000-64-26 2A 2NA t-2 Note) 24 VDC -2A: +COM. -2NA: COM. 2A 2NA SX3000-64-20 2A 2NA SX5000-64-20 t-3 2A 2NA SX3000-64-10 2A 2NA SX5000-64-10 t-4 t-5 SX5000-64-3A SX3000-64-3A In common between +COM and COM.
T1) terminal block) -1A: +COM -1NA: COM SX3000-64-1A 1NA SX5000-64-1A 1NA t-1 SX3000-64-26 2A 2NA SX5000-64-26 2A 2NA t-2 Note) 24 VDC -2A: +COM. -2NA: COM. 2A 2NA SX3000-64-20 2A 2NA SX5000-64-20 t-3 2A 2NA SX3000-64-10 2A 2NA SX5000-64-10 t-4 t-5 SX5000-64-3A SX3000-64-3A In common between +COM and COM.
A 24 VDC 5 Size 2 B E A B 4 N.C. Resin B C D E F G H J K L M N P Q R S T U V W 100 VAC Grommet 7 N.O. 110 VAC With surge voltage suppressor 200 VAC Size 3 C F A B 5 N.C.
ENT 84 88 Series LC1 Options T-nuts and T-brackets for Mounting Be sure to use when mounting the controller. Note) The controller unit includes either T-nuts or T-brackets.
11 Data A B A B A B A B MY-S40 55 M10 x 1.5 80 9 14.8 8.5 14 A B MY-S63 70 M12 x 1.75 100 11.5 18.3 10.5 17.5 Guide for Side Support Application For long stroke operation, the cylinder tube may be deflected depending on its own weight and the load weight.
B B B B B B RE A B 0 (0) 0 (0) 0 (2.5) 2 (6) 4 (7.5) 0 (0.5) 0 (0.5) 0 (3) 2.5 (6.5) 4.5 (8) 3.5 (6.5) 3.5 (6.5) 5.5 (9) 8.5 (12.5) 10.5 (14) 0 (2) 0 (2) 1 (4.5) 4 (8) 6 (9.5) 1 (4) 1 (4) 3 (6.5) 6 (10) 8 (11.5) 8.5 (11.5) 8.5 (11.5) 10.5 (14) 13.5 (17.5) 15.5 (19) 0.5 (3.5) 0.5 (3.5) 2.5 (6) 5.5 (9.5) 7.5 (11) 1 (0) 1 (0) 5.5 (1.5) 8.5 (4) 10.5 (6.5) 1.5 (0) 1.5 (0) 6 (2) 9 (4.5) 11 (7)
B B B B B B RE A B 0 (0) 0 (0) 0 (2.5) 2 (6) 4 (7.5) 0 (0.5) 0 (0.5) 0 (3) 2.5 (6.5) 4.5 (8) 3.5 (6.5) 3.5 (6.5) 5.5 (9) 8.5 (12.5) 10.5 (14) 0 (2) 0 (2) 1 (4.5) 4 (8) 6 (9.5) 1 (4) 1 (4) 3 (6.5) 6 (10) 8 (11.5) 8.5 (11.5) 8.5 (11.5) 10.5 (14) 13.5 (17.5) 15.5 (19) 0.5 (3.5) 0.5 (3.5) 2.5 (6) 5.5 (9.5) 7.5 (11) 1 (0) 1 (0) 5.5 (1.5) 8.5 (4) 10.5 (6.5) 1.5 (0) 1.5 (0) 6 (2) 9 (4.5) 11 (7)
is N r Rated voltage (Supply valve/Release valve) C1 V None None Cannot be selected when t is P or T Symbol Voltage 5 24 VDC 6 12 VDC L None V V Cannot be selected when t is N L1 None None V L2 None V None Cannot be selected when t is P or T L3 None None None 4 For the connector length other than 300 mm, order the connector assembly on page 32 separately. t Pressure switch for vacuum/Pressure
NCDQ8A(B)Z-(C)(M) (in) NCDQ8A(B)Z-T(M) (025st to 100st) (in) D-A9, D-A9V D-M9(V), D-M9W(V) D-A9, D-A9V D-M9(V), D-M9W(V) D-F9BAL D-F9BAL Bore size Bore size A B HS A B HS A B HS A B HS A B HS A B HS 056 075 106 150 200 250 300 400 056 075 106 150 200 250 0.24 0.14 0.33 0.31 0.2 0.35 0.37 0.49 0.04 0.08 0.12 0.12 0.2 0.28 0.34 0.53 0.71 0.81 0.96 1.18 1.45 1.6 1.94 2.44 0.39 0.3 0.49 0.47