Body Size: 3 (3/8 Basis), Control Method: 0 (Meter-out), Thread: F [G(PF)], Port Size: 03 (3/8), Sealant: S (Sealant)
Body Size: 3 (3/8 Basis), Control Method: 0 (Meter-out), Thread: F [G(PF)], Port Size: 03 (3/8), Sealant: None
Body Size: 3 (3/8 Basis), Control Method: 0 (Meter-out), Thread: F [G(PF)], Port Size: 03 (3/8), Sealant: S (Sealant)
Body Size: 3 (3/8 Basis), Control Method: 1 (Meter-in), Thread: F [G(PF)], Port Size: 03 (3/8), Sealant: S (Sealant)
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (Flow Adjustment Valve), Thread: F (G), Port Size: 03 (3/8), Output Specification: 1 (OUT1: Analog 1 to 5V)
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 03 (3/8), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor)
Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 03 (3/8), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector)
Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 03 (3/8), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor), Lead Wire: N (w/o Lead Wire w/M8 Connector)
Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 03 (3/8), Output Specification: 1 (OUT1: Analog 1 to 5V)
Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: S (Flow Adjustment Valve), Thread: F (G), Port Size: 03 (3/8), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector)
Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 03 (3/8), Output Specification: 2 (OUT1: Analog 4 to 20mA)
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 03 (3/8), Output Specification: 2 (OUT1: Analog 4 to 20mA)
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 03 (3/8), Output Specification: 1 (OUT1: Analog 1 to 5V)
Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: S (Flow Adjustment Valve), Thread: F (G), Port Size: 03 (3/8), Output Specification: 2 (OUT1: Analog 4 to 20mA)
Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: S (Flow Adjustment Valve), Thread: F (G), Port Size: 03 (3/8), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor)
Body Size: 30, Thread: F (G), Port Size: 03 (3/8), Option: Standard, Attachment: Standard, Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 30, Thread: F (G), Port Size: 03 (3/8), Option: Standard, Attachment: Standard, Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 30, Model Type: A (Filter Regulator + Lubricator), Thread: F (G), Port Size: 03 (3/8), Float Type Auto Drain: w/o Auto Drain, Pressure Gauge/Digital Pressure Switch: w/o Pressure Gauge, Attachment: without Attachment, Set Pressure: 0.05 to 0.85 MPa Setting, Bowl Type + Lubricator: Standard (Polycarbonate Bowl + Lubricator), Bowl Guard: None, Air Filter Drain Port: w/Drain Cock,
Size: 50, Standard Dew Point: -20°C, Type: A, Thread: F (G(PF)), Port Size: 03 (3/8), Accessory: None (Standard), Option: P (Fitting for Purge Air Exhaust)
Flow Range: 04 (0.5~4 l/min), Thread: F (G thread), Port Size: 03 (3/8), Wiring Specification: 3m Lead Wire w/Connector, Output Specification: 1 (Pulse Output + Analog Output (1~5V))