Indication of A B C D E F G T VCKH1209-02F VCKH1008-02F VCKH1075-02F VCKH0806-02F VCKH0604-02F 12/9 13 38.5 10 19 17 18.5 9 to 12 Nm 10/8 11 38 9 17 17 18.5 6 to 9 Nm 1075 11 38 9 17 17 18.5 6 to 9 Nm 8/6 9 36.5 8 14 14 16 4 to 9 Nm 6/4 7 36.5 8 12 14 15 3 to 8 Nm VCKK 40 swivel elbow 40 B A 10 Approx. F D Width across flats 14 Tightening torque: Tighten within 10 1 Nm. Approx.
I-MU02 I-MU03 I-MU04 I-MU05 R1 3 4 5 6 NZ 18 22 26 32 NX 9 11 13 16 NO 21 24 27 39 NL 8 10 10 16 R1 8.5 10 11 16 NDH10 NL 8.5 10 11 16 NX 9 11 13 16 NO 19.5 24 26 36 U1 11 14 15 20 U1 13 14 17 23 +0.058 0 +0.058 0 +0.058 0 +0.070 0 8 10 10 14 Knuckle pin and snap ring are included. Clevis pin and knuckle pin Rod end nut 30 d Dd9 d D C l m m t t L H B (mm) (mm) Part no.
SMC 7 23 3.4 6.2 3.2 15 11 Most sensitive position 8.5 10-20-56 57 Water Resistant 2-color Indication Type Solid State Switch: Tie-rod Mounting Style D-F5BAL For details about certified products conforming to international standards, visit us at www.smcworld.com.
B-B B Component Parts Component Parts (Right/Left side parallel only) No.
The process and suction status can then be compared. 8 Diagnosis (flow rate) 0: OFF 1: ON 14 Fixed output 0: OFF 1: ON 15 Diagnosis (error) 0: OFF 1: ON 16 to 31 Measured flow rate value Signed 16 bit Bit offset 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 Item Measured flow rate value (PD) Bit offset 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Item Error Fixed Reservation Flow rate Reservation
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 60
When the temperature of the circulating fluid is set to lower than 10oC, use a 15% aqueous solution of ethylene glycol. Tap water may freeze in the thermo-chiller, leading to malfunction. 15% aqueous solution of ethylene glycol When a 15% aqueous solution of ethylene glycol is used, prepare the ethylene glycol aqueous solution separately.
+ 8 9 10 A 11 B 12 13 NBR 14 15 16 17 18 ( DC24V) 4 - 4.
80 30 30 15 220 180 30 26 26 2 x 5.4 11 11 20 32 22 4.5 High-voltage unit full length: 220 mm High-voltage unit full length: 180 mm 31 (Full length of high-voltage unit and control unit) (Full length of high-voltage unit and control unit plus 62 mm) With bracket How to Order IZS31 180 X210 R Sensor Bar type Without bracket With bracket Note) Nil Bracket Without sensor Autobalance sensor
ZPT2-7A-X2 ZP 13 B ZPG13B-7A-X2 7 8 8 8 ZP13B ZP 16 B ZPG16B-7A-X2 8 8 8 9 ZP16B ZP 20 B ZPG20B-7A-X2 11 11 11 13 ZP20B ZPT3-7A-X2 ZP 25 B ZPG25B-7A-X2 11 12 12 14 ZP25B ZP 32 B ZPG32B-7A-X2 14 15 15 18 ZP32B ZP 20 UT ZPG20UT-7A-X2 4 4 4 4 ZPT1-A6 ZP2-20UT ZP 16 J ZPG16J-7A-X2 8 8 8 9 ZPT2-7A-X2 ZP2-16J ZP B25 J ZPGB25J-7A-X2 14 15 15 18 ZP2-B25J ZPT3-7A-X2 ZP B30 J ZPGB30J-7A-X2
ISO size 1 Series VQ7-6 ISO size 1 Max. 10 stations 0.43n + 0.49 (n: Stations) 1/4 3/8 Bottom Note) When equipped with control unit, 1 or 2 stations are used for mounting. 3-10-11 12 Series VQ7-6 DIN Terminal Type VV71-100 80 100 2n-1/4, 3/8 80 23 37 9 14 9 15 U side U side Manual override R4.5 R4.5 Indicator light P = 43 53.5 P = 43 53.5 B B B B 9 9 B 23 20 SMC SMC SMC 9 A PA A B B A PA
Method of Mounting Two Auto Switches at the Stroke End of a Cylinder for Strokes Less Than 20 mm Auto switch model Applicable strokes 15 mm stroke 20 mm stroke 15 6 3 A 6 A 20 0.5 D-M9m(V) D-M9mW(V) D-M9mA(V) 0.5 3 6 B 6 B The correct mounting position of the D-M9 is 3 mm from the end face of the switch holder (dimensions A and B).
Normal output Reversed output P_1(P_2)=A-(A-B)/4 n_1(n_2)=B+(A-B)/4 A = Maximum pressure H_1(H_2)= (A-B)/2 H_1(H_2)= (A-B)/2 B = Minimum pressure If setting is not necessary press the UP and DOWN buttons simultaneously for 1 second or longer. -46No.PS-OMW0012-C [F 6] Fine adjustment of display value This function is to manually perform a fine adjustment of the displayed pressure value.
175 152 17 6 198 187.5 168 15 7 210.5 200 184 13.5 8 223 212.5 200 11.5 9 248 237.5 216 16 10 260.5 250 232 14 L1 L2 L3 L4 (mm) Stations 11 273 262.5 248 12.5 12 298 287.5 264 17 13 310.5 300 280 15.5 14 323 312.5 296 13.5 15 333.5 325 312 12 16 360.5 350 328 16.5 17 373 362.5 344 14.5 18 385.5 375 360 13 19 398 387.5 376 11 20 423 412.5 392 15.5 L1 L2 L3 L4 3-3-93
HED003-W2 A B 13 19 HED003-C2A B (Temperature Controller) HED003-HW13 19 (Heat Exchanger) HED005-W2 A B 13 19 HED005-C2A B (Temperature Controller) HED005-HW13 19 (Heat Exchanger) HED007-W2 A B 13 19 HED007-C2A B (Temperature Controller) HED007-HW13 19 (Heat Exchanger) Keep this manual available whenever necessary.
ACA201M ACA202M ACA203M CKZ-50A001 CKZ-50A002 CKZ-50A003 CKZ-50A007 CKZ-50A008 CKZ-50A009 0.6 (1.32) 0.7 (1.54) 0.9 (1.98) 0.7 (1.54) 0.8 (1.76) 1.0 (2.20) Straight-Machined 25 mm Offset-Machined A A B B 8F7+0.013 +0.028 through C C D D E E F G 8F7+0.013 +0.028 through F G 20 0.03 10 3 20 0.03 30 0.025 30 0.025 10 H 11 through 30 0.025 30 0.025 I 11 through M6 x 1.0 M6 x 1.0 H I 15 0.03 15
Choo6e Manffold Block porling desired. e.g. # 11, # rg or # 15. 4. To specify a valve hountsd on a manitold blo,ck Inlen manilold numbr into valv numbr i.e. NVS 411+tt09D b a NVS 4114-0O0gD valv6 ,nount6d oo a # 11 blc'*,. 5.
Name Alarm flag 1 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 2 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Name Explanation 0 Abnormal low tank fluid level 1 Low tank fluid level 2 None 3 None 4 None 5 Fan failure Alarm flag 1 6 None 7 None 8 Abnormal rise of circulating fluid temperature 9 Circulating fluid temperature rise 10 Circulating fluid temperature drop 11 TEMP READY