SMC Corporation of America
Elite Part Number Search
Search Results "10-SS5YJ7-21-03-00N"

8 20.8 9 53 35 54 52 30 148 11.2 10 40 6 6 166 30 32 10 10 24 9 65 47 64 62 40 178 14.5 12.2 47.5 Rc, NPT, G1/8 7 6 211 33 39 14 10 31 13.5 79 52 92 77 44 225 16 15 64 Rc, NPT, G1/8 8.5 7.5 259 40 46 15 14 37 14 94 66 112 92 60 276 19.5 16.5 80 Rc, NPT, G1/4 8.5 8.5 293 44 58 25 15 47.5 21 116 74 142 114 66 310 20.5 20 95 Rc, NPT, G3/8 10 10 336 64 70 29 16 58 20 139 99 162 136 84 356 23.5

(inch) Note) 2-Applicable tubing Weight (g) A P L M D2 D1 5 32 KJX01-03 KJX03-07 1 8 34.6 35.4 10 10 12.7 12.7 8.4 9.3 44 45.7 8.4 9.3 2.8 3.6 5 32 1 4 Note) D1: Max. diameter Applicable fitting 15-4-7 Series KJ Branch Y: KJU Connection thread (T) UNF NPT 10-32 UNF <10-32 UNF> 10-32> Applicable tubing O.D.

MLGPM, MLGPL common dimensions (mm) IC Standard stroke (mm) Bore size (mm) B C DA FA FB G GA GB H HA IA IB Extension locking Retraction locking ID IE IF IG IH J K L 79.5 10 10 12 32.5 8.5 9 9 83 M5 M5 M6 26.5 36 40 49 M5 x 0.8 6.5 7 8 21.2 18 21 24 10 12 16 36 42 48 10.5 37 9.5 10 9 24 30 34 6 7.5 9 18 21 24 32 3 20 25 32 20, 30, 40, 50, 75, 100, 125 150, 175, 200, 250, 300, 350 84 36.5

MLGPM, MLGPL common dimensions (mm) IC Standard stroke (mm) Bore size (mm) B C DA FA FB G GA GB H HA IA IB Extension locking Retraction locking ID IE IF IG IH J K L 79.5 10 10 12 32.5 8.5 9 9 83 M5 M5 M6 26.5 36 40 49 M5 x 0.8 6.5 7 8 21.2 18 21 24 10 12 16 36 42 48 10.5 37 9.5 10 9 24 30 34 6 7.5 9 18 21 24 32 3 20 25 32 20, 30, 40, 50, 75, 100, 125 150, 175, 200, 250, 300, 350 84 36.5

O N 1 2 3 4 5 6 7 8 9 10 F-Address 512 128 64 32 16 8 2 value 256 4 1 Fig. 10-7 PROFIsafe address switch Note: The F-Address bit numbering shown on the label has priority over any numbers printed on the DIP switch e.g. in the example above the DIP switch is printed with numbers 1 to 10 where 1 is on left and 10 is on the right.

Torr (mmHg) 10-12 10-11 10-10 10-9 10-8 10-7 10-6 10-5 10-4 10-3 10-2 10-1 1 10 102 3. Mount a valve with its coil position upward, not downward. 10-12 10-11 10-10 10-9 10-8 10-7 10-6 10-5 10-4 10-3 10-2 10-1 1 101 102 103 104 105 106 107 108 109 Pa Vacuum piping direction: if the system uses a vacuum pump, we ask that you install the vacuum pump on the secondary side.

Core wire colors Brown: Not connected Note 1), 24 VDC 10% (Control power supply) Note 2) White: 24 VDC +10%/5% (Solenoid valve power supply) Blue: Not connected Note 1), 0 V (Control power supply) Note 2) Black: 0 V (Solenoid valve power supply) Gray: Not connected Brown: 24 VDC +10%/5% (Solenoid valve power supply) White: 0 V (Solenoid valve power supply) Blue: 24 VDC 10% (Control power

Note5) Note6) Y110-M5-A Y210-01-A Y310-(01)-A Y410-(02)-A Y510-(02)-A Y610-03-A Y610-(03)-A VHS40-02A VHS20-01A VHS30-02A VHS50-06A Pressure relief 3 port valve Note6) VHS40-03A VHS40-06A Attachment VHS20-02A VHS30-03A VHS50-10A VHS40-04A E400-02-A E200-01-A E300-02-A E400-03-A E600-06-A Piping adapter Note6) E100-M5-A E200-02-A E300-03-A E500-06-A E400-04-A E600-10-A E200-03-A E300-04

capacity [kW] 8 8 6 6 4 4 2 2 0 0 5 10 15 20 25 30 35 5 10 15 20 25 30 35 Circulating fluid temperature [oC] Circulating fluid temperature [oC] 50Hz 60Hz Fig. 8-5 Cooling capacity(HRS100-A-20/40/46-) 8.4.2 HRS150-A-20/40/46: Ambient temperature: 32 oC : Ambient temperature: 40oC : Ambient temperature: 45 oC 18 18 16 16 14 14 Cooling capacity [kW] Cooling capacity [kW] 12 12 10 10 8 8 6 6

Made to Order (For details, refer to pages 16 to 21.)

Enable Generates an error. 1 Unit Disable Does not generate an error. -10..10 V Selects the analogue input range. (AXB cannot select the following ranges. -10..10 V/ -5..5 V/ -20..20 mA) -5..5 V -10..10 V -20..20 mA (AXA) Sets the analogue input device range. 0..10 V 2 Analogue input range Channel 0..5 V 1..5 V (AXB) 1..5 V 0..20 mA 4..20 mA Offset binary Offset binary.

VHS400-02 VHS401-02 VHS400-03 VHS401-03 VHS400-04 VHS401-04 VHS500-06 VHS501-06 Pipipng direction Port size 3 4 1 2 3 8 1 4 1(P) 2(A) 21 105 76 54 35 35 57 93 Effective area (mm2) Mass (kg) 2(A) 3(R) 0.25 0.34 The front face of the handle is the reference position. Easy to Operate The direction of air flow can be verified at a glance by the orientation of the handle.

Guide Series LTF Lead screw lead mm Mounting orientation Motor type Series Page Model Guide type Ground ball screw Rolled ball screw 6 10 20 10 20 10 20 10 20 6 10 20 10 20 10 20 10 20 LTF6 LTF8 LTF6 LTF8 LTF6 LTF8 LTF6 LTF8 P.2 Horizontal 10 10 P.10 Standard motor 6 6 P.18 Vertical 10 10 P.26 Frame-type linear guide LTF 6 6 P.34 Horizontal Courtesy of Steven Engineering, Inc.-230 Ryan Way

6.5 7.0 7.5 8.0 Parallel gripper 6.5 7.0 7.5 8.5 30 to 10 30 to 10 30 to 10 22.5 to 10 Angular gripper 180 opening/closing 88 to 5 54 to 6 58 to 5 41 to 5 30 to 4 Note) The operating range for grippers is measured when both ends are open.

LED 3 P LED FS LED Fig. 10-5 EX245-FPS1/2/3 LED 10.9.3.1. FS LED Table 10-27 FS LED LED F-iSI 10.9.3.2. P LED Table 10-28 P LED LED Acknowledgement 64 No.EX##-OMY0006CN 10.10. MAC FW/HW Firmware version (FW): 2.1.X Hardware version (HW): 03 and higher Fig. 10-6 10.11. DIP 10.11.1.

Series 10-/11-/21-/22-CDG1 Series 10-/11-REC Series 10-/11-CDM2X Series Perpendicular entry is unavailable.

: 45 oC 12 12 10 10 Cooling capacity [kW] Cooling capacity [kW] 8 8 6 6 4 4 2 2 0 0 5 10 15 20 25 30 35 5 10 15 20 25 30 35 Circulating fluid temperature [oC] Circulating fluid temperature [oC] 50Hz 60Hz Fig. 9-5 Cooling capacity(HRS090-A-20/40/46) 9.4.2 HRS090-W-20/40/46: Facility water temperature 32 oC : Facility water temperature 40 oC 12 14 12 10 10 Cooling capacity [kW] Cooling capacity

L/min 0 to 1 L/min 0 to 3 L/min 0.5 to 0.5 L/min 5 to 500 L/min 5 to 500 L/min 10 to 1000 L/min 20 to 2000 L/min 2 to 200 L/min 1 to 1 L/min 10 to 1000 L/min 3 to 3 L/min 20 to 2000 L/min Power supply voltage 24 VDC 10% 12 to 24 VDC 10% 12 to 24 VDC 10% 24 VDC 10% 12 to 24 VDC 10% 12 to 24 VDC 10% Temperature characteristics 2% F.S. 2% F.S. (15 to 35C) 2% F.S. (15 to 35C) (25C standard)

Supply from one side 8 10 10 M5 x 0.8 Supply from both sides 10 12 12 Note) These values are obtained under the standard supply pressure.

How to Order Integrated Display Type M PF2A7 10 01 27 Flow rate range 1 to 10 l/min 5 to 50 l/min 10 to 100 l/min 20 to 200 l/min 50 to 500 l/min 10 50 11 21 51 Thread type Unit specification Nil M With unit switching function Fixed SI unit Note) Nil N F Lead wire (Refer to page 35.)