Enable Generates an error. 1 Unit Disable Does not generate an error. -10..10 V -5..5 V -20..20 mA 0..10 V 2 Analogue input range Sets the analogue input device range. Selects the analogue input range. -10..10 V Channel 0..5 V 1..5 V 0..20 mA 4..20 mA Offset binary Offset binary.
Weight (g) Model End boss type (Symbol) M K E W MHZ2-10 65 66 65 64 MHZ2-16 147 148 148 147 MHZ2-20 277 277 277 277 MHZ2-25 494 496 495 495 12-2-41 41 Parallel Style Air Gripper With Dust Cover Series MHZJ2 Size: 6, 10, 16, 20, 25 How to Order MHZJ2 16 F9BW D Number of auto switches Number of fingers Nil S 2 pcs. 1 pc. 2 2 fingers Bore size Auto switch Action 6 10 16 20 25 6 mm 10 mm 16 mm
Weight (g) Model End boss type (Symbol) M K E W MHZ2-10 65 66 65 64 MHZ2-16 147 148 148 147 MHZ2-20 277 277 277 277 MHZ2-25 494 496 495 495 12-2-41 41 Parallel Style Air Gripper With Dust Cover Series MHZJ2 Size: 6, 10, 16, 20, 25 How to Order MHZJ2 16 F9BW D Number of auto switches Number of fingers Nil S 2 pcs. 1 pc. 2 2 fingers Bore size Auto switch Action 6 10 16 20 25 6 mm 10 mm 16 mm
ZH13DL-08-02-10 14.2 S type: White color L type: Black color 14.2 Applicable tubing diameter N ZF 14.2 Applicable tubing diameter E 14.2 17.2 ZP 17.2 19.95 ZCU 19.95 93.3 58.5 41 10 15.3 4.2 19 ZH15DS-10-03-12 22.45 AMJ 93.3 58.5 41 10 15.3 4.2 19 ZH15DL-10-03-12 22.45 (Mounting hole) Model I J K L M N O P Misc.
10 15 15 20 MS4-10 MS5-10 MS6-15 MS6-15 MS8-20 Left Right Left Right Operating direction of the housing Operating direction of the housing Manufactured by Misumi Trading Ltd.
10 15 15 20 MS4-10 MS5-10 MS6-15 MS6-15 MS8-20 Left Right Left Right Operating direction of the housing Operating direction of the housing Manufactured by Misumi Trading Ltd.
A B C D E F G H J K Y300T-A 4.2 82 41 71.5 35 14 7 19 4 41 Y400T-A 5.2 96 48 86.1 40 18 9 26 5 50 Ordering Example Dual residual pressure release valve with soft start-up function VP544-5DZ1-03-X538 1 pc. Filter regulator AW30-03G-A 1 pc. Spacer with bracket Spacer with bracket Y300T-A 3 pcs. Piping adapter E300-03-A 2 pcs. Each product is not assembled.
10 18 The body mounting reference plane should be used as a standard when mounting onto equipment.
A B C D E F G H J K Y300T-A 4.2 82 41 71.5 35 14 7 19 4 41 Y400T-A 5.2 96 48 86.1 40 18 9 26 5 50 Ordering Example Dual residual pressure release valve with soft start-up function VP544-5DZ1-03-X538 1 pc. Filter regulator AW30-03G-A 1 pc. Spacer with bracket Spacer with bracket Y300T-A 3 pcs. Piping adapter E300-03-A 2 pcs. * Each product is not assembled.
Model Port size Effective area (mm2) Weight (g) ANB1-01 22 81 25 18 35 93 30 21 94 107 46 24 175 133 50 41 462 190 74 41 612 230 74 60 871 271 86 70 A B C Dimensions (mm) 1 8 ANB1-02 15 10 51 22 1 4 ANB1-03 35 3 8 ANB1-04 60 1 2 ANB1-06 90 3 4 ANB1-10 160 1 1 1 ANB1-12 280 1 4 ANB1-14 450 1 2 610 Construction/Parts/Dimensions ANB1-01 to 04 JIS symbol ANB1-04: PP ANB1-06 to 14 How to Order
range Circulating fluid return 0.1 10 0 0 0 2 4 6 8 10 12 14 16 18 20 Circulating fluid flow [L/min] It is available in case of Pressure control mode or Set output mode.
P.5-10 It indicates the set temperature. (10) Circulating fluid set temperature P.5-10 CH2 Press the numeric section to change the set temperature. (11) Circulating fluid discharge pressure It indicates the discharge pressure.
Bore size (mm) Z DA DB DL DU DC DX DE DR DO DT DS DH Z DD H10 +0.058 0 +0.058 0 +0.070 0 +0.070 0 +0.084 0 +0.084 0 32 40 50 63 80 100 32 40 50 63 80 100 6.6 6.6 9 9 11 11 46 52 65 75 95 114 32 32 43 43 64 64 22 22 30 30 45 45 10 10 11.5 11.5 14 14 44 44 60 60 86 86 14 14 20 20 30 30 62 62 81 81 111 111 15 15 18 18 22 22 7 7 8 8 10 10 33 33 45 45 65 65 154 158 182 182 228 228 10 10 14 14
151 14 20 18 36 10 57.5 71.5 65.5 7 11.2 6.6 33 158.4 64 79.5 78 5.5 76.5 8 54 62 72 40 185 209 10 199 14 22 18 36 10 64.5 195.2 59 83.5 78 8 14.7 9 39 173.4 79 95 6.6 9 67 76 89 50 202 235 14 221 20 28 22 44 14 76.5 215.7 71 94 91 91 97 9 16.2 11 46 177.4 95 9 9 80 92 60 203 238 14 224 20 30 22 44 14 89.5 219.2 84.5 109.5 113 107 108 * Dimensions for auto switch model D-F79W. 4.4-13 3 Point
Dimensions (mm) Recommended flow m3/min (ANR) Model Port size R Effective area (mm2) Weight (g) A B C 1 8 ANB1-02 15 10 51 22 ANB1-01 22 81 25 18 35 93 30 21 94 107 46 24 175 133 50 41 462 190 74 41 612 230 74 60 871 271 86 70 1.2 or less 2.7 or less 3.8 or less 7.0 or less 12.0 or less 20.0 or less 32.0 or less 45.0 or less 1 4 ANB1-03 35 3 8 ANB1-04 60 1 2 ANB1-06 90 3 4 ANB1-10 160 1
Contact protection box CD-P11 LED Brown OUT Brown Choke coil Resistor Reed switch Zener diode Surge absorber OUT Blue Blue Weight (g) D-A73 D-A72 D-A73 D-A80 Auto switch model 10 10 10 0.5 Lead wire length (m) 47 47 47 3 LED Brown OUT (+) Brown Contact protection box CD-P11 CD-P12 77 5 Resistor Reed switch Zener diode Dimensions OUT () Blue Blue Indicator light D-A80 without indicator
Indicator light Output 1 and 2: Orange Power supply Used as switch output device 12 to 24 VDC, including ripple (p-p) 10% voltage Used as IO-Link device 18 to 30 VDC, including ripple (p-p) 10% Current consumption 50 mA max.
(mm) Connection thread R 10 D1 Note) D2 Model L1 L2 FR soft nylon FR double layer KRK06-02S KRK06-01S 1 8 12 10 33 13 21 35 25 26 36 33 MS 20.5 24.5 26.5 22 26 28 24 27 29 33 27.5 29.5 33.5 10 18 36.5 35 1 4 19 3.4 14 17 12 14 17 6 12.8 6.9 KRK06-03S 37 19.7 3 8 1 8 Applicable tubing T KRK08-01S KRK08-02S KRK08-03S KRK10-01S KRK10-02S KRK10-03S 1 4 3 8 1 8 1 4 3 8 39 41 42 43.5 45 15.2 12
M1 M2 M3 m1 m2 m3 16 25 40 16 25 40 16 25 40 5 4 3.5 18 16 14 MY2H 13 14 10 35 35 30 45 33 28 68 66 57 7 6 7 15 13 13 MY2H 28 26 26 32 30 30 60 50 60 62 62 62 46 55 46 20 18 18 MY2HT 100 120 100 38 35 35 200 220 200 80 80 80 The above values are the maximum allowable values for moment and load.