Body Size: 20, Thread: NPT, Port: 1/4, Option: Standard, Attachment: K + T + V, Semi-Standard 1: Standard, Semi-Standard 2: Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F
Body Size: 40, Thread: NPT, Port: 1/2, Option: C + E, Attachment: K + S, Semi-Standard 1: Standard, Semi-Standard 2: Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F
Body/Exhaust Type: A (Single Unit - Silencer Exhaust), Nominal Nozzle Size: 15 (ø1.5), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 07 [ø1/4 One-touch Fitting
Body/Exhaust Type: C (For Manifold - Common Silencer Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 07 [ø1/4 One-touch
Body/Exhaust Type: C (For Manifold - Common Silencer Exhaust), Nominal Nozzle Size: 10 (ø1.0), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 07 [ø1/4 One-touch
Body/Exhaust Type: C (For Manifold - Common Silencer Exhaust), Nominal Nozzle Size: 12 (ø1.2), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 07 [ø1/4 One-touch
Body/Exhaust Type: C (For Manifold - Common Silencer Exhaust), Nominal Nozzle Size: 15 (ø1.5), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 07 [ø1/4 One-touch
Body/Exhaust Type: H (For Manifold - High-noise Reduction Silencer Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 07 [
Body/Exhaust Type: H (For Manifold - High-noise Reduction Silencer Exhaust), Nominal Nozzle Size: 15 (ø1.5), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 07 [
Body/Exhaust Type: A (Single Unit - Silencer Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 07 [ø1/4 One-touch Fitting
Body/Exhaust Type: A (Single Unit - Silencer Exhaust), Nominal Nozzle Size: 10 (ø1.0), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 06 [ø6 One-touch Fitting (
Body/Exhaust Type: A (Single Unit - Silencer Exhaust), Nominal Nozzle Size: 10 (ø1.0), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 07 [ø1/4 One-touch Fitting
Body/Exhaust Type: A (Single Unit - Silencer Exhaust), Nominal Nozzle Size: 12 (ø1.2), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 06 [ø6 One-touch Fitting (
Body/Exhaust Type: A (Single Unit - Silencer Exhaust), Nominal Nozzle Size: 12 (ø1.2), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 07 [ø1/4 One-touch Fitting
Body/Exhaust Type: A (Single Unit - Silencer Exhaust), Nominal Nozzle Size: 15 (ø1.5), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 06 [ø6 One-touch Fitting (
Body/Exhaust Type: A (Single Unit - Silencer Exhaust), Nominal Nozzle Size: 15 (ø1.5), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 08 [ø8 One-touch Fitting (
Body/Exhaust Type: A (Single Unit - Silencer Exhaust), Nominal Nozzle Size: 15 (ø1.5), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 09 [ø5/16 One-touch Fitting
Body/Exhaust Type: B (Single Unit - Port Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric
Body/Exhaust Type: C (For Manifold - Common Silencer Exhaust), Nominal Nozzle Size: 15 (ø1.5), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 6 (12 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 08 [ø8 One-touch Fitting
Body/Exhaust Type: F (For Manifold - Individual Port Exhaust), Nominal Nozzle Size: 15 (ø1.5), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 07 [ø1/4 One-touch