Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: Z (w/o Lead Wire w/Connector)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: w/o Lead Wire, Bracket: A1 (Bracket A, Vertical Mounting)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: w/o Lead Wire, Bracket: A1 (Bracket A, Vertical Mounting)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: w/o Lead Wire, Bracket: D (Panel Mount Adapter + Front Protection Cover)
Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: w/o Lead Wire, Bracket: B (Panel Mount Adapter), Operation Manual: T (w/o Operation Manual, Calibration Certificate)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: w/o Lead Wire, Bracket: D (Panel Mount Adapter + Front Protection Cover)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: w/o Lead Wire, Bracket: A1 (Bracket A, Vertical Mounting)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: w/o Lead Wire, Bracket: A1 (Bracket A, Vertical Mounting)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: w/o Lead Wire, Bracket: D (Panel Mount Adapter + Front Protection Cover)
Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: w/o Lead Wire, Bracket: A1 (Bracket A, Vertical Mounting), Operation Manual: T (w/o Operation Manual, Calibration Certificate)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: N (NPN Open Collector 1 Output), Unit Specification: w/Unit Selection Function, Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: A1 (Bracket A, Vertical Mounting), Option 3: Y (w/o Operation Manual, w/o Calibration Certificate)
Standard strokes range from 25 to 800mm., C(P)96 CYLINDER *LQA, ACTUATOR, C95/C96 TIE-ROD CYLINDER, LD, 32MM C95/CP95 DOUBLE-ACTING, 2.40205 lb
Standard strokes range from 25 to 800mm., C(P)96 CYLINDER *LQA, ACTUATOR, C95/C96 TIE-ROD CYLINDER, LD, 32MM C95/CP95 DOUBLE-ACTING, 1.69755 lb
Standard strokes range from 25 to 800mm., C(P)96 CYLINDER *LQA, ACTUATOR, C95/C96 TIE-ROD CYLINDER, LD, 32MM C95/CP95 DOUBLE-ACTING, 2.03927 lb
Standard strokes range from 25 to 800mm., C(P)96 BASE CYLINDER, ACTUATOR, C95/C96 TIE-ROD CYLINDER, LD, 32MM C95/CP95 DOUBLE-ACTING, 3.74785 lb
Standard strokes range from 25 to 800mm., C(P)96 BASE CYLINDER, ACTUATOR, C95/C96 TIE-ROD CYLINDER, LD, 32MM C95/CP95 DOUBLE-ACTING, 3.80297 lb
Standard strokes range from 25 to 800mm., C(P)96 CYLINDER *LQA, ACTUATOR, C95/C96 TIE-ROD CYLINDER, LD, 32MM C95/CP95 DOUBLE-ACTING, 3.74785 lb
Standard strokes range from 25 to 800mm.Double Acting, Bore Sizes 32, 40, 50, 63, 80, 100, 125, End of Stroke Cushioning, C(P)96 CYLINDER, ACTUATOR, C95/C96 TIE-ROD CYLINDER, LD, 32MM C95/CP95 DOUBLE-ACTING, 2.40303 lb
Standard strokes range from 25 to 800mm.Double Acting, Bore Sizes 32, 40, 50, 63, 80, 100, 125, End of Stroke Cushioning, C(P)96 CYLINDER, ACTUATOR, C95/C96 TIE-ROD CYLINDER, LD, 32MM C95/CP95 DOUBLE-ACTING
Standard strokes range from 25 to 800mm., C(P)96 BASE CYLINDER, ACTUATOR, C95/C96 TIE-ROD CYLINDER, LD, 32MM C95/CP95 DOUBLE-ACTING, 1.76369 lb