Indicator light (With "Z") 69(Without "Z": 59) 59(Without "Z": 49) 190 NAMUR Interface 3 Port Solenoid Valve VFN200N Series NAMUR Mounting Pattern Axis A-A' can be aligned to suit.
Mineral oil A A A C A A 18 Sodium hypochlorite (2%, Room temperature) A C D A D B 19 Sodium chloride A A A A B 20 Carbon dioxide A A A A A A 21 Natural gas A A A A A A 22 Boric acid A B D A A B 23 Unless noted otherwise, the solution concentration is in a saturated state.
When a load, such as a relay or solenoid, which generates surge is directly driven, use a type of switch with a built-in surge absorbing element. 8.
Mineral oil A C A A A A 18 Sodium hypochlorite (2%, Room temperature) A C A D D B 19 Sodium chloride A A A A B 20 Carbon dioxide A A A A A A 21 Natural gas A A A A A A 22 Boric acid A B A D A B 23 Unless noted otherwise, the solution concentration is in a saturated state.
B Z + Stroke DB DX DD 90 B 4DT A DS DH 4DR DB DU DO DO DC DE DU DL Rotation (mm) No.
Z (Example) F9NWZ Solid state auto switches with a "" symbol are produced upon receipt of order.
The L, Z and ZZ dimensions are reference dimensions when mounting a double knuckle joint.
connector (M): SX7 20-MC8 C10 C8 C10 128.6 300 141.1 99.2 99.2 19 42.9 (Lead wire length) 19 42.9 Polarity indication 13.6 13.6 A B A B B A A COM B + A B A B A B A Manual override (Push and turn for locking type) 42 31.4 Manual override (Press and turn for the locking type) 42 31.4 84.9 B: Green A: Orange 2-4.2 84.9 B: Green A: Orange 2-4.2 2-One-touch fittings (Mounting holes for manifold
With orifice: 10 to 150 Hz with a 1.5 mm amplitude or 19.6 m/s2 acceleration, in each X, Y, Z direction for 2 hrs, whichever is smaller.
Gain switching input Pin no. 12 13 14 19 20 21 22 23 24 25 26 Symbol IM COM GND OZ+ Pin no. 1 2 3 4 5 6 7 8 9 10 11 Signal description Torque monitor signal Control signal power supply Symbol COM+ SRV-ON A-CLR CL GAIN DIV CWL CCWL ALM COIN SP A 35 Driver model MSD013P1E MSD011P1E MSD023P1E MSD021P1E 45 Z phase output Z phase output Z phase output CW pulse input CW pulse input CCW pulse input
restriction circuit using a speed controller, etc.
Air filter (5m or less) When using a solenoid valve, use a metal seal type (series VQ, VQZ, SQ, etc.).
C C RHC D D Note) Be sure to use a flat washer for the type A mounting.
Vertical Operation 1 2 P2 W A P1 a (b) (a) P0 P0 a A W (1) The speed is controlled with meter-out control. When the meterin controller is used in conjunction with the meter-out controller, lurching is reduced. () (2) Depending on the size pf the load, installing a regulator with check valve at position (a) can decrease lurching during descent, and operation delay during ascent.
Vertical Operation 1 2 P2 W A P1 a (b) (a) P0 P0 a A W (1) The speed is controlled with meter-out control. When the meterin controller is used in conjunction with the meter-out controller, lurching is reduced. () (2) Depending on the size pf the load, installing a regulator with check valve at position (a) can decrease lurching during descent, and operation delay during ascent.
Power saving circuit is only available in the "Z" type. Note) When placing an order for body ported solenoid valve as a single unit, mounting bolt for manifold and gasket are not attached. Order them separately, if necessary.
Do not use a screwdriver with a large grip or with a tip that does not fit into the trimmer groove because this could strip the groove.