This is a legacy product. Please contact us for the latest version.sales@ocaire.com, PRESSURE SWITCH, DIGITAL, INSTRUMENTATION, ISE70/75 PRESSURE SWITCH, D7, ISE70/75 1/4 EURO VERSION, .99820 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, PRESSURE SWITCH, DIGITAL, INSTRUMENTATION, ISE70/75 PRESSURE SWITCH, D7, ISE70/75 1/4 EURO VERSION, .88184 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, PRESSURE SWITCH, DIGITAL, INSTRUMENTATION, ISE70/75 PRESSURE SWITCH, D7, ISE70/75 1/4 EURO VERSION, .96203 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, PRESSURE SWITCH, DIGITAL, INSTRUMENTATION, ISE70/75 PRESSURE SWITCH, D7, ISE70/75 1/4 EURO VERSION, .44000 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, PRESSURE SWITCH, DIGITAL, INSTRUMENTATION, ISE70/75 PRESSURE SWITCH, D7, ISE70/75 1/4 EURO VERSION, .61710 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, PRESSURE SWITCH, DIGITAL, INSTRUMENTATION, ISE70/75 PRESSURE SWITCH, D7, ISE70/75 1/4 EURO VERSION, .54560 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, PRESSURE SWITCH, DIGITAL, INSTRUMENTATION, ISE70/75 PRESSURE SWITCH, D7, ISE70/75 1/4 EURO VERSION, .54560 lb
Note 2) Drain guide is NPT1/8 (applicable to the AW20(K)-B) and NPT1/4 (applicable to the AW30(K)-B to AW60(K)-B). The auto drain port comes with 3/8" One-touch fitting (applicable to the AW30(K)-B to AW60(K)-B). Note 3) Drain guide is G1/8 (applicable to the AW20(K)-B) and G1/4 (applicable to the AW30(K)-B to AW60(K)-B).
Rated Pressure Range: -0.1 to 1 MPa, Piping: R1/4, M5 Female, Rear Ported, Input/Output: PNP Open Collector 2 Outputs, Option 1: w/Unit Display Switching Function, Option 2: w/Bracket Rear Ported Only, Option 3: Operating Manual Booklet, X Options: Lead Wire Length 3m
Rated Pressure Range: -0.1 to 1 MPa, Piping: NPT1/4, M5 Female, Rear Ported, Input/Output: PNP Open Collector 2 Outputs, Option 1: w/Unit Display Switching Function, Option 2: w/Bracket Rear Ported Only, Option 3: Operating Manual Booklet, X Options: Lead Wire Length 3m
Rated Pressure Range: -0.1 to 1 MPa, Piping: NPT1/4, M5 Female, Rear Ported, Input/Output: PNP Open Collector 2 Outputs, Option 1: w/Unit Display Switching Function, Option 2: w/Bracket Rear Ported Only, Option 3: Operating Manual Booklet, X Options: Restrictor Installed Fitting
Rated Pressure Range: -100 to 100 kPa, Piping: NPT1/4, M5 Female, Rear Ported, Input/Output: PNP Open Collector 2 Outputs, Option 1: W/Unit Display Switching Function, Option 2: w/Bracket Rear Ported Only, Option 3: Operating Manual Boklet, X Options: Lead Wire Length 3m
pressure switch *5 67 Regulator AR20-B to AR60-B Series Regulator with Backow Function AR20K-B to AR60K-B Series AC AF+AR+AL AW+AL AF+AR AF+AFM+AR AW+AFM AF Attachment AFM / AFD AR AL AW AR40-B, AR40K-B AR20-B, AR20K-B Nq Body size 20 25 30 40 50 60 Symbol Description c Set pressure *6 Nil 0.05 to 0.85 MPa setting 1 0.02 to 0.2 MPa setting + d Exhaust mechanism Nil Relieving type N Non-relieving
AR60K-B Construction AR10-A AR20(K)-B/AR25(K)-B AC AF+AR+AL AW+AL AF+AR AF+AFM+AR AW+AFM AF Attachment AFM / AFD AR AL AW t e q IN OUT t e q r IN OUT w r w AR30(K)-B/AR40(K)-B q t AR50(K)-B/AR60(K)-B e IN OUT q t r w e IN OUT r w Component Parts No.
Set pressure range [MPa] 0.1 to 1.7 Ambient and fluid temperature [C] 5 to 60 (with no freezing) Applicable Model Applicable Model Model AR25-B AR30-B AR40-B AR40-06-B AR50-B AR60-B Model AR20-B AR25-B AR30-B AR40-B AR40-06-B AR50-B AR60-B Port size 1/4, 3/8 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 1 Port size 1/8, 1/4 1/4, 3/8 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 1 r BG AR B B X430 30 03 BG q 30 AR
The cost effective and clean looking AC series allows you to pick a combination of modular style air preparation equipment that best suits your needs. The series, available in 8 size options to ensure optimum performance, offers energy savings, with higher flow rates. Simple assembly and maintenance reduces downtime. New Style piping adapter attachment , Easy maintenance , Detach equipment
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IF/PFA FLOW SWITCH, DX, IF/PFA 1/4 INCH ALL OTHERS, 1.10231 lb, ModelMeasured fluidFlow rate measurement rangeSet flow rate rangeRated flow rangeMinimum set unitAccumulated pulse flow rate exchange value (Pulse width: 50 ms)Note 1, 2)Display unitsOperating
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IF/PFA FLOW SWITCH, DX, IF/PFA 1/4 INCH ALL OTHERS, 1.71960 lb, ModelMeasured fluidFlow rate measurement rangeSet flow rate rangeRated flow rangeMinimum set unitAccumulated pulse flow rate exchange value (Pulse width: 50 ms)Note 1, 2)Display unitsOperating
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MECH VALVE W/ACTUATORS, VALVE, VM (VFM/VZM) MECHANICAL VALVE, FA, VM BODY PT 1/4, .46541 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, SWITCH ASSEMBLY, VACUUM SERIES, ZSE40/50/60 VACUUM SWITCH, KC, ZSE40/50/60 1/4 PORTED, .44092 lb, ModelRated pressure rangeSet pressure rangeWithstand pressureWetted parts materialApplicable fluidPort sizePower supply voltageCurrent consumption--Switch outputRepeatabilityHysteresisAnalog outputAuto-shift