Function: 1 (2 Position Single), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: D (DIN Terminal w/Connector), Light/Surge Suppressor: Z (With light/surge voltage suppressor), Manual Override: E (Push-turn Locking Lever Type), Port Size: 02 (1/4)
Function: 1 (2 Position Single), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 6 (12VDC), Lead Wire: D (DIN Terminal w/Connector), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: Non-locking Push Type, Port Size: 02 (1/4), Thread: T (NPTF)
Function: 1 (2 Position Single), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: B (24VAC), Lead Wire: D (DIN Terminal w/Connector), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: Non-locking Push Type, Port Size: 02 (1/4), Thread: T (NPTF)
Function: 1 (2 Position Single), Piping: 4 (Base Mounted), Exhaust: 4 (Base), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 4 [220VAC (230VAC) 50/60Hz], Lead Wire: D (DIN Terminal w/Connector), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: Non-locking Push Type, Port Size: 02 (1/4)
Function: 1 (2 Position Single), Piping: 4 (Base Mounted), Exhaust: 4 (Base), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: D (DIN Terminal w/Connector), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: Non-locking Push Type, Port Size: 02 (1/4), Thread: N (NPT)
Function: 1 (2 Position Single), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: D (DIN Terminal w/Connector), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: Non-locking Push Type, Port Size: 02 (1/4), Thread: T (NPTF)
Function: 1 (2 Position Single), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 4 [220VAC (230VAC) 50/60Hz], Lead Wire: D (DIN Terminal w/Connector), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: Non-locking Push Type, Port Size: 02 (1/4)
Function: 3 (3 Position Closed Center), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: D (DIN Terminal w/Connector), Light/Surge Suppressor: Z (With light/surge voltage suppressor), Manual Override: Non-locking Push Type, Port Size: 02 (1/4)
Function: 1 (2 Position Single), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 1 (100VAC 50/60Hz), Lead Wire: D (DIN Terminal w/Connector), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: Non-locking Push Type, Port Size: 02 (1/4)
Function: 4 (3 Position Exhaust Center), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: D (DIN Terminal w/Connector), Light/Surge Suppressor: Z (With light/surge voltage suppressor), Manual Override: Non-locking Push Type, Port Size: 02 (1/4)
Function: 1 (2 Position Single), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 6 (12VDC), Lead Wire: D (DIN Terminal w/Connector), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: Non-locking Push Type, Port Size: 02 (1/4), Thread: N (NPT)
Function: 1 (2 Position Single), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Pressure Specification: K (High-pressure, 1MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: D (DIN Terminal w/Connector), Light/Surge Suppressor: Z (With light/surge voltage suppressor), Manual Override: Non-locking Push Type, Port Size: 02 (1/4)
Function: 1 (2 Position Single), Piping: 4 (Base Mounted), Exhaust: 4 (Base), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 6 (12VDC), Lead Wire: D (DIN Terminal w/Connector), Light/Surge Suppressor: S (Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Port Size: 02 (1/4), Thread: N (NPT)
Function: 3 (3 Position Closed Center), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 1 (100VAC 50/60Hz), Lead Wire: D (DIN Terminal w/Connector), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: Non-locking Push Type, Port Size: 02 (1/4)
Function: 3 (3 Position Closed Center), Piping: 4 (Base Mounted), Exhaust: 4 (Base), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: B (24VAC), Lead Wire: D (DIN Terminal w/Connector), Light/Surge Suppressor: Z (With light/surge voltage suppressor), Manual Override: Non-locking Push Type, Port Size: 02 (1/4)
Model: Side-Ported, Serial Interface, SI Unit Specification: w/o SI Unit, SI Unit Output Polarity: Positive Common, NPN or w/o SI Unit, Valve Stations: 02 Stations, P, E Port Location: D Side, SUP/EXH Block: Internal Pilot, A, B Port Size: ø6 One-touch Fitting, Mounting: -, DIN Rail Option: -
Model: Side-Ported, Serial Interface, SI Unit Specification: w/o SI Unit, SI Unit Output Polarity: Positive Common, NPN or w/o SI Unit, Valve Stations: 02 Stations, P, E Port Location: D Side, SUP/EXH Block: Internal Pilot, A, B Port Size: ø4 One-touch Fitting, Mounting: -, DIN Rail Option: -
Model: Side-Ported, Serial Interface, SI Unit Specification: EtherNet/IPâ„¢ - 16 Outputs - Connector M12, SI Unit Output Polarity: PNP, Valve Stations: 02 Stations, P, E Port Location: D Side, SUP/EXH Block: Internal Pilot, Built-in Silencer, A, B Port Size: ø1/4" One-touch Fitting, Mounting: -, DIN Rail Option: -
Stations: 02, System, Port Combinations: Ejector System, Common PV: ø5/16", Inch Size, Exhaust: 2 [Vacuum Pump System, w/o Silencer; (Ejector System has Individual Exhaust Port)], Wiring: Individual Wiring Specification, Option: D [w/Common Release Pressure Supply (PD) Port], Manifold Assembly, Delivery Condition: Delivered as Individual Parts, not Assembled
Body Size: 30, Thread: N (NPT), Port Size: 02 (1/4), Option: D (N.O., Float Type Auto Drain), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F), Made to Order: X2141 (w/Element Service Indicator)