MAXIMUM APPLICABLE FLOW RATE 1500 Maximum applicable flow rate / 1000 AFD40-A 500 AFD30-A AFD20-A 0 0.0 0.2 0.4 0.6 0.8 1.0 Inlet pressure MPa 7. TROUBLESHOOTING Refer to 8. CONSTRUCTION / PARTS LIST (P10), 11. DISASSEMBLY DRAWING (P23). TROUBLE POSSIBLE CAUSE REMEDY DEMARCATION PHENOMENON 1. 1. Replace the element. Clog of the element. Large air resistance reduces flow rate.
If it is a shorter operating time, there is a possibility of accidental breaker trip due to the internal motors inrush currents of this product. 4h 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s Operating time Max. 10s 5s 2s Min. 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s 100 135 200 300 400 500 600700 1000 1500 2000 3000 4000 Current (% for breaker capacity) Breakers operating characteristic
Signal Red Black Brown Blue 4 5 1 2 Lock (+) Lock () Sensor (+) Note) Sensor () Note) B-1 A-1 B-3 A-3 Note) Not used for the LE series 52 Series LECP2 Options [Power supply cable] LEC CK1 1 (15.8) (7.9) (6) (10.5) (13.3) (35) (60) (1500) Conductor size: AWG20 Terminal name Covered color Function 0V M 24V C 24V BK RLS Common supply () Blue White Brown Black Motor power supply (+) Control
condensation. (1) Calculation method of volume ratio (Kv value) Basic conditions Supply dew point: 20C (Atmospheric pressure dew point) Supply pressure: 0.5 MPa Solenoid valve operating intervals: 1 s (ON) 1 s (OFF) Ambient temperature: 25C Ambient humidity: 40% Vt = = = 62800 mm3 d2l 4 x 42 x 5000 4 100 O.D. 2 mm tube Vc = = = 75 mm3 D2s 4 x 42 x 6 4 50 Kv = = 837 Vt Vc 0 0 300 600 900 1200 1500
Supply pressure: 0.3 to 1.0 MPa Set pressure: 0.2 MPa Flow rate: 0 L/min (ANR) IR3000-03 IR3000-03 IR3000-03 Supply pressure: 0.5 MPa Back pressure: 0.5 MPa 0.204 0.5 0.2 Set pressure P2 (MPa) Set pressure (MPa) Set pressure (MPa) Set pressure (MPa) 0.202 0.4 Set point 0.15 0.200 0.3 0.1 0.198 0.2 0.196 0.05 0.1 0.194 0 0.2 0.1 0.4 0.3 0.6 0.5 0.8 0.7 0.9 1.0 0 500 1000 1500 2000 2500 3000
Flow Rate Characteristics Relief Characteristics IR2020-02-A Supply pressure: 0.7 MPa IR2020-02-A Back pressure: 0.7 MPa ARJ 0.7 0.7 0.6 0.6 AR425 to 935 Set pressure [MPa] Set pressure [MPa] 0.5 0.5 ARX 0.4 0.4 AMR 0.3 0.3 0.2 0.2 ARM 0.1 0.1 ARP 0 0 500 1000 1500 2000 0 0 150 300 450 600 IR-A IR-A Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] IR IRV Pressure Characteristics VEX Supply
Supply pressure [MPa] Flow Rate Characteristics Relief Characteristics Supply pressure: 1.0 MPa Supply pressure: 1.0 MPa 1.0 1.0 0.9 0.9 0.8 0.8 Set pressure [MPa] Set pressure [MPa] 0.7 0.7 0.6 0.6 0.5 0.5 0.4 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0.0 0.0 0 500 1000 1500 2000 0 100 200 300 400 500 600 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] 960 ITVH2000 Series 3.0 MPa Maximum Supply Pressure
Please order it separately if necessary. 1 1 30 JSX022 Cable length L [mm] 1 1000 2 2000 5 5000 Specification 1 For DC voltages 2 For AC voltages Specifications Part number JSX022-30-1-m JSX022-30-2-m Key type A-coded B-coded Rated current 4 A Rated voltage 250 V Rating/Performance Contact resistance 40 m or less Insulation resistance 1000 M or more Withstand voltage 1500 VAC Operating temperature
Low Voltage Directive This directive is applied to products, which operate above 50 VAC to 1000 VAC and 75 VDC to 1500 VDC operating voltage, and require electrical safety measures to be introduced. Simple Pressure Vessels Directive This directive is applied to welded vessels whose maximum operating pressure (PS) and volume of vessel (V) exceed 50 bar/L.
Low Voltage Directive This directive is applied to products, which operate above 50 VAC to 1000 VAC and 75 VDC to 1500 VDC operating voltage, and require electrical safety measures to be introduced. Simple Pressure Vessels Directive This directive is applied to welded vessels whose maximum operating pressure (PS) and volume of vessel (V) exceed 50 bar/L.
AWG22 Wire diameter (Including insulator) 1.5 mm Item Specifications Cable O.D. 6 mm Nominal cross section 0.3 mm2/AWG22 Wire diameter (Including insulator) 1.5 mm Min. bending radius 40 mm (Fixed) Min. bending radius 40 mm (Fixed) Cable core wire colors Brown White Blue Black Gray Terminal no. 1 2 3 4 5 Connections SPEEDCON PCA1401804 PCA1557769 Cable length (L) Cable length (L) 1401804 1500
a minimum pipe bore of 10 mm, and a maximum length of 5 m (when installing an optional auto drain). 180C Inlet air temperature Correction factor Air flow (l/min (ANR)) Cooling water (l/min) Model 70C 41.5 43 45.5 37 43 49.5 37 43 45.5 37 42 43.5 50C 38.5 40 42 36 40 45.5 36 40 42.5 36 40 41 100C 37.5 47 51 38 44.5 48 35.5 36 36.5 33.5 36 38 33.5 36 36.5 33.5 35 36 200 300 400 500 1000 1500
How to Order M Type Connector Assembly ON OFF ON OFF Lead wire length Positive common specifications Nil 6 10 15 20 25 30 50 SX100-40-4S300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm For single solenoid: Normal operating state. Switching of valve is based on an electric signal from the connector.
selected, the barriers equivalent to the number of solenoids are included with the product. 52-SY9000 Electrical entry Port size (Base mounted type) Plug connector type Plug connector with cover type Cable type L LL TT Symbol Port size Applicable series Without sub-plate Nil 02 02 03 03 04 1/4 1/4 3/8 3/8 1/2 52-SY5000 Lead wire length 52-SY7000 3 6 10 15 20 30 100 300 mm 600 mm 1000 mm 1500
Standard Specifications AMR3000 AMR4000 AMR5000 AMR6000 Model 1 1 4, 3 8 1 4, 3 8, 1 2 1 2, 3 4 3 4, Port size Fluid Air Proof pressure 1.5 MPa 1.0 MPa Max. operating pressure 0.05 to 0.85 MPa Setting pressure range 5 to 60C (No freezing) Ambient and fluid temperature Relieving type Construction 0.3 m Filtration Max. 1.0 mgf/Nm3 ( 0.8 ppm) (1)(2) Oil mist density in the outlet side 750 1500
Filtration Max. 1.0 mgf/Nm3 ( 0.8 ppm) (1)(2) Oil mist density in the outlet side IR 750 1500 3500 6000 Rated flow (/min (ANR)) (3) 1.8 2.8 3.5 6.7 VEX Weight (kg) Note 1) Compressed air density: 30 mgf/Nm3. Note 2) An element for the mist separator is included on the inlet side. Mineral grease is applied on the sliding parts inside the regulator.
1 4, 3 8 1 4, 3 8, 1 2 1 2, 3 4 3 4, Port size Air Fluid 1.5MPa Proof pressure 1.0MPa Max. operating pressure Min. operating pressure (1) 0.05MPa 0.05 to 0.85MPa Setting pressure range 5 to 60C (No freezing) Ambient and fluid temperature Relieving style Construction Filtration 0.3m (2) (3) 750 Max. 1.0mgf/Nm3 ( 0.8ppm) Oil mist density on the secondary side Rated flow (l/min (ANR)) (4) 1500
Low Voltage Directive This directive is applied to products, which operate above 50 VAC to 1000 VAC and 75 VDC to 1500 VDC operating voltage, and require electrical safety measures to be introduced. Simple Pressure Vessels Directive This directive is applied to welded vessels whose maximum operating pressure (PS) and volume of vessel (V) exceed 50 bar/L.
AS2052F-A AS1002F-A AS2002F-A 500 Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 01, 23, 03, 04, 06, 07 100 08, 09 06, 07 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] 400 200 06, 07 03, 04 300 50 200 100 100 0 0 0 0 5 10 0 5 10 0 5 10 Number of needle rotations Number of needle rotations Number of needle rotations AS3002F-A AS4002F-A 1500
Effective area (mm2) Effective area (mm2) 06, 08 08, 10 1.0 300 06 04 2 4 50 100 200 0.5 1 2 100 0.0 0 0 0 0 0 0 5 10 0 5 10 0 5 10 Number of needle rotations (turns) Number of needle rotations (turns) Number of needle rotations (turns) ASG520F-03 ASG521F-03 ASG620F-04 ASG621F-04 Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 1000 25 15 Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) 1500