Table 3 Specification-3 Size Weightg Internal capacitycm 90 180 360 90 180 360 10 120 150 200 1.2 2.2 4.3 15 220 270 380 2.9 5.5 10.7 20 600 700 1000 7.1 13.5 26.3 30 900 1100 1510 12.1 22.9 44.7 40 1400 1600 2280 20.5 39 76 -17- 1-2 Effective output Fig.1 Effective output 1-3 Rotation range When pressurized from the Port A, the shaft will rotate clockwise.
. -3- 1Specification High performance Battery-less absolute encoder LESYH*(D,R,L)G* LESYH LESYH LESYH LESYH LESYH LESYH LESYH Model 8*GA 8*GB 8*GC 16*GA 16*GB 25*GA 25*GB Stroke[mm] 50,75 50,100 50,100,150 Max.work load[kg] 2 8 12 Horizontal Vertical 1.5 3 6 6 12 10 20 note1)note3) Pushing Force 18~36 37~74 69~138 70~140 135~270 197~395 382~765 note1)note3) 20~800 10~400 5~200 20800 10400
Pressure 1.0MPa Ambient Temperature 2 ~ 40oC(Relative Humidity of 85% or less) Power source 1 AC230V10% 50Hz (Note 4) Specification Operating current(Note 2) 1.2A 1.2A 1.2A 1.4A 2.7A 2.9A Electrical Power consumption(Note 2) 180W 180W 180W 208W 385W 420W Circuit Breaker (Note 3) 5A 10A Noize at 50Hz 50dB Condenser Air cooling Refrigerant R134aHFC(WGP:1300) Refrigerant Charge Quantitiy 150 5g 200
Lead wire color (grommet) Voltage Color SOL 100 VAC Blue Cylinder Xa Xb Xc Yb Ya Mode 200 VAC Red Upward High speed a DC Red (+), Black () Low speed b Downward High speed c How to use the needle Low speed d Rotate the needle clockwise to close, and counterclockwise to open.
Voltage specification Colour DIN connector B1B09-2A (Standard) GM209NJ-B17 (CE-compliant) 100 VAC Blue 200 VAC Red DC polar indication Red (+), black (-) Others Gray 7 VT307-OMQ0002-B VT307 Series 3 port solenoid valve/ Specific Product Precautions (2) Be sure to read before handling.
Lead Wire Color (Grommet) Caution Voltage Color 100 VAC Blue 200 VAC Red DC Red (+), Black () Other Gray Electrical Connection DIN terminal is connected inside as in the figure below. Connect to the corresponding power supply. Caution 7 VT317-OMH0002-B Specific Product Precautions (2) Be sure to read this before handling the products. How to wire DIN terminal 1.
Model Allowable pressing load (N) MHM-16D 100 MHM-25D 200 MHM-32D 300 MHM-50D 500 5. Do not apply impact load to the center of the magnetic attraction surface. Otherwise, it may result in a breakage or malfunction. 6. The head cap is magnetized during the release of workpiece. Iron particles may be attracted. 7 - 2-3 Environment Warning 1.
disassembly of the SI unit -24No.EX-OMN0011-F Specifications Specifications General specifications Item Specifications Ambient temperature -10 to +50 oC Ambient humidity 35 to 85%RH (No condensate) Ambient temperature for storage -20 to +60 oC Withstand voltage 500 VAC applied for 1 minute Insulation resistance 500 VDC, 10 M or more Operating atmosphere No corrosive gas Enclosure IP67 Weight 200
disassembly of the SI unit -30No.EX-OMO0030-E Specifications Specifications General specifications Item Specifications Ambient temperature -10 to +50 oC Ambient humidity 35 to 85%RH (No condensate) Ambient temperature for storage -20 to +60 oC Withstand voltage 500 VAC applied for 1 minute Insulation resistance 500 VDC, 10 M or more Operating atmosphere No corrosive gas Enclosure IP67 Weight 200
disassembly of the SI unit -25No.EX-OMP0005-I Specifications Specifications General specifications Item Specifications Ambient temperature -10 to +50 oC Ambient humidity 35 to 85%RH (No condensate) Ambient temperature for storage -20 to +60 oC Withstand voltage 500 VAC applied for 1 minute Insulation resistance 500 VDC, 10 M or more Operating atmosphere No corrosive gas Enclosure IP67 Weight 200
.: 1.12 mm Mass With sensor cable 200 g 108 g 194 g 102 g 201 g 109 g Without sensor cable 187 g 95 g 203 g 111 g 193 g 101 g -12No.PS-OMG0006-D Analogue output Range Rated pressure range A B C For vacuum 0 to -101 kPa 0 -101 kPa 10.1 kPa For compound -100 to 100 kPa -100 kPa 100 kPa 0 to 1 MPa 0 1 MPa -0.1 MPa For positive pressure 0 to 500 kPa 0 500 kPa -50 kPa -13No.PS-OMG0006-D Dimensions
disassembly of the SI unit -31No.EX-OMW0016-A Specification Specifications General specifications Item Specifications Ambient temperature -10 to +50 oC Ambient humidity 35 to 85%RH (No condensate) Ambient temperature for storage -20 to +60 oC Withstand voltage 500 VAC applied for 1 minute Insulation resistance 500 VDC, 10 M or more Operating atmosphere No corrosive gas Enclosure IP67 Weight 200
Wiring Communication wiring Cable: Shielded twisted pair cable (Type-A cable) Impedance 135 to 165 ohm(3 to 20 MHz) Capacity between conductors 30 pF/m or less Conductor resistance 110 /km or less Cable diameter 0.64 mm or more Conductor area 0.34 mm2 or more Transmission speed & Maximum wiring length Baud rate (kbps) 9.6 19.2 45.45 93.75 187.5 500 1500 12000 Wiring length (m) 1200 1000 400 200
Operating Pressure 0.7MPa Inlet Air Temperature 55oC Ambient Temperature 32oC Pressurized Dew Point 10oC Working Fluid Compressed Air Operating Inlet Air Temperature 5 ~ 80oC Range Inlet Air Pressure 0.15 ~ 1.0MPa Ambient Temperature 2 ~ 40oC(Relative Humidity of 85% or less) 100V AC(50/60Hz) Single phase AC100/100 , 110VVoltage fluctuations10% Power source 200V AC(50/60Hz) Single phase AC200/200
Network length Communication speed [kbps] 9.6 19.2 45.45 93.75 187.5 Max. cable length [m] 1200 1000 Communication speed [kbps] 500 1500 3000 6000 12000 Max. cable length [m] 400 200 100 : Maximum cable length differs depending on the specifications of a cable. The above cable length is based on type A cable.
Current consumption 55 mA or less Protection Polarity protection Power supply voltage for sensor Power supply voltage: -1.5 V Power supply current for sensor 1 Max. 50 mA (Max. 200 mA for total power supply current when sensor 4 input) Accuracy Display accuracy 0.5%F.S. 1 digit (at ambient temperature 253 oC) Repeatability 0.1%F.S.1 digit Temperature characteristics 0.5%F.S. (25 oC standard
Valve specifications Model XLAV-16-2 XLAV-25-2 XLAV-40-2 XLAV-50-2 XLAV-63-2 XLAV-80-2 Flange (valve) size 16 25 40 50 63 80 Actuating type Normally closed Fluid Vacuum of inert gas Operating temperature oC 5 to 50 Operating pressure Pa(abs) Atmospheric pressure to 1 x 10-6 Conductance l/s Note 1) 5 14 45 80 160 200 Internal 1.3 x 10-10 for the standard material (FKM) Leakage at ambient temperatures
Mass of transferred object: 200 (kg) 2. Transfer speed: 20 (m/min) 3. Operating pressure: 0.5 (MPa) 4. Coefficient of friction of conveyor: 0.1 Input operating requirements. Determine cylinder bore size temporarily. Cylinder bore size is determined as 50 temporarily. Calculate allowable maximum impact load mmax by using conveyor friction coefficient .
HECR008: 100 to 240VAC HECR012: 200 to 240VAC (This function works when the control operation mode is 2 in level setting 1) When pressed during auto tuning, the auto tuning is stopped.
0.5MPa 1000 1000 0.3MPa 0.3MPa 500 500 0 0 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 6.5 7 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 6.5 7 Shim Shim thickness (mm) thickness (mm) 0.3MPa 0.3MPa Recommended shim thickness Recommended shim thickness 0.5MPa 0.5MPa 0.7MPa 0.7MPa 9 - Arm length L300mm 1800 Peak clamping force position 1600 0.7MPa 1400 1200 Clamping force (N) 0.5MPa 1000 800 600 0.3MPa 400 200