Size: M5, Reverse Flow Function: Standard, Thread: M Thread, Rc(PT), Port Size: M5, Accessory 1: C [Float Style Auto Drain (N.C.)], Accessory 2: Round Pressure Gauge, Option 1: -, Option 2: -, Option 3: -
Size: M5, Reverse Flow Function: Standard, Thread: M Thread, Rc(PT), Port Size: M5, Accessory 1: Bracket, Accessory 2: None, Option 1: None, Option 2: C [Bowl Guard (Size 2000 Only)], Option 3: -
Size: M5, Reverse Flow Function: Standard, Thread: M Thread, Rc(PT), Port Size: M5, Accessory 1: C [Float Style Auto Drain (N.C.)], Accessory 2: None, Option 1: Metal Bowl, Option 2: -, Option 3: -
Size: M5, Reverse Flow Function: Standard, Thread: M Thread, Rc(PT), Port Size: M5, Accessory 1: None, Accessory 2: None, Option 1: Metal Bowl, Option 2: None, Option 3: Flow Direction: Right->Left
Size: M5, Reverse Flow Function: Standard, Thread: M Thread, Rc(PT), Port Size: M5, Accessory 1: Bracket, Accessory 2: None, Option 1: Metal Bowl, Option 2: None, Option 3: Flow Direction: Right->Left
Size: M5, Reverse Flow: Regulator, Standard, Thread: M Thread, Rc(PT), Port Size: M5, Accessory: Round Pressure Gauge, Option 1: Non-relieving, Option 2: Name Plate & Pressure Gauge in Imperial Units, PSI, °F
Size: M5, Reverse Flow: Regulator, Standard, Thread: M Thread, Rc(PT), Port Size: M5, Accessory: Panel Mount w/Set Nut, Option 1: 0.02~0.2MPa Setting+Non-relieving, Option 2: Flow Direction: Right->Left
Size: M5, Reverse Flow: Regulator, Standard, Thread: M Thread, Rc(PT), Port Size: M5, Accessory: B+G, Option 1: 0.02~0.2MPa Setting, Option 2: Name Plate & Pressure Gauge in Imperial Units, PSI, °F
Size: M5, Reverse Flow: Regulator, Standard, Thread: M Thread, Rc(PT), Port Size: M5, Accessory: G+H, Option 1: 0.02~0.2MPa Setting, Option 2: Name Plate & Pressure Gauge in Imperial Units, PSI, °F
Size: M5, Thread: M Thread, Rc(PT), Port Size: M5 x 0.8, Accessory: Float Style Auto Drain, N.C., Attachment: T Spacer, Option 1: Lubricator w/Drain Cock, Option 2: Non-relieving, Option 3: -
Size: M5, Thread: M Thread, Rc(PT), Port Size: M5 x 0.8, Accessory: Float Style Auto Drain NC, Attachment: None, Option 1: None, Option 2: None, Option 3: Name Plate, Caution on Bowl
Size: M5, Thread: M Thread, Rc(PT), Port Size: M5 x 0.8, Accessory: Pressure Gauge, Attachment: None, Option 1: None, Option 2: Flow Direction: Right->Left, Option 3: Name Plate, Caution on Bowl
Size: M5, Thread: M Thread, Rc(PT), Port Size: M5 x 0.8, Accessory: Pressure Gauge, Attachment: None, Option 1: Lubricator w/Drain Cock, Option 2: None, Option 3: Name Plate, Caution on Bowl
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?