s2 (10 G) in X, Y, Z directions for 2 hrs. each (De-energized) 980 m/s2 (100 G) in X, Y, Z directions 3 times each (De-energized) In a temperature range of 0 to 50C, 2% F .S. or less of pressure measured at 25C Vibration resistance Impact resistance Temperature characteristics 01: R 1/8, M5 x 0.8, T1: NPT1/8, M5 x 0.8, W1: Rc 1/8 C4: With 4 One-touch fitting, C6: With 6 One-touch fitting,
A G Dimension table G 1/8 1/4 F 12 14 E 4 6 D 10 12 C 23.8 24.5 B 40.8 44.5 A 37 42 Model G3601 G4602 Specifications G3601 R 1/8 G4602 R 1/4 270 Rolled steel plate (black melamine coated) Polycarbonate Brass 55g 80g Model Piping port size Scale angle Case Installing the Cover After setting the indicator needles, return the cover to its original position by aligning the indentation at the
Function: 1 (Normally Closed), Piping: 2 (Body Ported), Body Option: M (Common EXH), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: M (M Plug Connector w/Lead Wire 0.3m), Surge Suppressor: R (Surge Suppressor Non-polar), Manual Override: D (Push-turn Locking Slotted Style), Port Size: 01 (Base Mounted w/Sub-plate 1/8, Body Ported 1/8), Thread: N (NPT), Bracket: F (Bracket)
HOW TO ORDER N V F 1 1 0 H s D Z O 0 1 T F T T Opo.afing Pressure -J I 0 100 psi (CrP.055) | ' H 0 r 150 psi (C\p.05) | Solen
Type, Flow Direction: R (Flow Direction: Right to Left), Drain Cock w/Barb Fitting: None, Pressure Units: Z [Product: psi, °C; Pressure Gauge: psi (and MPa)], D: D
Type, Flow Direction: R (Flow Direction: Right to Left), Drain Cock w/Barb Fitting: None, Pressure Units: Z [Product: psi, °C; Pressure Gauge: psi (and MPa)], D: D
1.0 x8 M6 x 1.0 x10 12REA 50/63 0 -0.2 L NA 33 2-Rc, NPT, G 1/4 14 14 E(h8) E(h8) X D I 4-TC 14 14 Effective thread depth R 23 22 K W 23 25 2 4-M8 x 1.25 25 8-Q 14.5 C 0.1 + Effective thread depth 12 Effective thread depth R B S + Stroke 2 ZZ + Stroke Q x R S TC x R Model L 122 110 K 38 32 C 70 60 X ZZ NA E D B 72.2 58.2 I 70 60 W 12-REA63 12-REA50 100 86 66 53 30-0.033 69 55 M10 x 1.5 x
Outside Local Area: (800) 258-9200-www.stevenengineering.com ZSP ISA2 IS ZSM PF2 01: R 1/8 T1: NPTF 1/8 IF 2-3.5 Mounting hole 13 Data M5 x 0.8 Connector type 30 SE3C I Z 01 T1 20.5 RESET button DOWN button SET button UP button Lead wire length 600 39 8.5 3.5 (3000) 10 01: R 1/8 T1: NPTF 1/8 2-3.5 Mounting hole 13 M5 x 0.8 16-4-7 8 Series ZSE3/ISE3 Dimensions/Switch Only Grommet type ZSE3
HOW TO ORDER N V F 1 1 0 H s D Z O 0 1 T F T T Opo.afing Pressure -J I 0 100 psi (CrP.055) | ' H 0 r 150 psi (C\p.05) | Solen
Rated Vacuum Range: -100 to 100 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket A, Vertical Mounting, Operation Manual: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: None, Operation Manual: Operation Manual, Calibration Certificate
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: 01 (R 1/8)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A, Vertical Mounting)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: None, Operation Manual: K (Operation Manual, Calibration
L4 Note) Weight (g) 5 5.5 6.5 8.5 9.5 19 22 35 38 52 86 95 Model Applicable tubing O.D. d AS1002F-01 AS1002F-03 AS1002F-07 AS2002F-03 AS2002F-07 AS2052F-07 AS2052F-09 AS3002F-07 AS3002F-09 AS3002F-11 AS4002F-11 AS4002F-13 MIN.
Filtration rating has to be 5m or smaller. 3(R) Model VHS2500 VHS3500 VHS4500 VHS5500 A 60 78 85 136 B 20 29 32 56 C 12.8 12.8 12.6 32 D 40 53 70 90 E 44 53 64 80 F 33 42 49 65 G 28 29 36 54 H 7.5 7.5 10 10 3.6-18
-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Error of scale 0.05 MPa ZSP Repeatability 0.05 MPa Contacts 1a ISA2 Wiring specifications Grommet, Lead wire length 0.5 m (Standard) IS Fluid Air Ambient and fluid temperature 5 to 60C (No freezing) ZSM Port size R 1/8 PF2 Weight 74 g Switch Characteristics IF IS1000-01 IS1000-01-X202 Data Max. contact