If the tightening torque is exceeded the mounting screws may be broken. IP65 protection cannot be guaranteed if the screws are not tightened to the specified torque. Never mount a product in a location that will be used as a foothold. The product may be damaged if excessive force is applied by stepping or climbing onto it.
After tightening by hand, the barb fitting type should be tightened by an additional 1/4 rotation using an appropriate wrench. 2. After tightening by hand, the barb elbow type should be tightened by an additional 1/2 rotation using an appropriate wrench. 2) M5 1. After tightening by hand, the barb fitting type should be tightened by an additional 1/6 rotation using a suitable tool. 2.
Built-in strainer in the pilot valve Unexpected troubles due to foreign matter can be prevented. Note) Be sure to mount an air filter on the inlet side.
Note) Manifold gasket SYJ3000-14-2 can be used with the following manifold bases.
Please contact SMC when the cylinder has to be diassembled for the purpose of replacing seals, etc. 1 NBR (FKM can be selected.) 17 O-ring (Rod end) 1 NBR 18 O-ring (Head end) 3 (FKM can be selected.)
Total current for OUT 0 to 7 must be 1 A or less. Total current for OUT 8 to 15 must be 1 A or less.
These can be ordered using the order number for each bore size.
When In the exhaust posiiion, the vahre may be padlock secured. Prevents accidental start-ups whil personnl ate cleanlng or serviclng equipment. operated valve can be used to The supply/exhaust status of the air flo$r can be verified al a glance in the indicating windour.
These can be ordered using the order number for each bore size.
N373 Check Valve with One-touch Fitting AKH/AKB Series Bushing Type Can be used in applications with splashing coolant and spatter, etc.
As a rule, they should be tightened 2 to 3 turns with a tool after first tightening by hand.
Vacuum pressure switches There will be no change in performance if a pressure of approximately 0.5 MPa is applied momentarily (when releasing vacuum), but care should be taken that pressures of 0.2 MPa or more are not applied on a regular basis. Operating Environment Warning 1. The product cannot be used in a strong magnetic field. 1020
Avoid applications in which two or more end lock cylinders are synchronized to move one workpiece, as one of the cylinder locks may not be able to release when required. 6. Use a speed controller with meter-out control. Lock cannot be released occasionally by meter-in control. 7. Be sure to operate completely to the cylinder stroke end on the side with the lock.
The instruction manual should be carefully read and fully understood before the product is installed and operated. Also, the manual should be kept where it can be easily referred to at any time. 2. Allow space for maintenance. Allow the space necessary for maintenance and inspections. 3. Tighten screws with the proper tightening torque.
In this case, an intermediate stop can be performed only by using an external stopper, etc. Note 2) Depending on the operating environment, etc., made-to-order products should also be reviewed. (Refer to pages 9 through 13.)
The load should be applied to the piston rod in an axial direction.
The load should be applied to the piston rod in an axial direction.
Therefore, the cylinder should be connected in a way to absorb the displacement, and a proper setting should be maintained to prevent deflection due to excessive force wherever the stroke is placed. At the same time, take measures to lower particle generation friction of the materials. 7.
The locked condition can be confirmed with the visible orange section. Lock ring Turn the lock ring in the locking direction as shown by the arrow.
The stroke can be set in 1 mm increments.