Body/Exhaust Type: G (Single Unit - High-noise Reduction Silencer Exhaust), Nominal Nozzle Size: 15 (ø1.5), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 06 [ø6
How to Order Integrated Display Type PF2A7 H M Flow rate range Unit specification High flow rate type 03 06 12 150 to 3000 l/min 300 to 6000 l/min 600 to 12000 l/min Lead wire (Refer to page 35.)
Model A L D KQ2P-04 KQ2P-06 KQ2P-08 4 6 32 16 6 8 35 18 8 10 39 20.5 A A A A A B B 6 Cassette Type Manifold Series SZ3000 Manifold Options DIN rail dimensions/Weight table D-sub connector (25 pins)/Cable assembly AXT100-DS25015 030 050 VZ1000-11-1Refer to the L dimension tables Enter a number from the DIN rail dimension table below in the .
In-line type How to Order JIS Symbol 1F 12 K 400 AS Option Body size Nil K N None Hexagonal lock nut Electroless nickel plated If more than one option is required, write option part numbers in the order of K, N. M5 standard 1/8 standard 1/4 standard 3/8 standard 1/2 standard 100 200 205 300 400 Applicable tubing O.D.
(Piping: JIS K 6349 high pressure hose) External Pilot Caution Pilot port piping Combination between the VNA series and Speed controller (AS series) 12(P1) and 10(P2) piping should be as follows according to the model. VNA AS Piping (I.D.)
Alarm1 Water Leak Detect FLT 01 Alarm2 Incorrect Phase Error FLT 02 Alarm3 RFGT High Press FLT 03 Alarm4 CPRSR Overheat FLT 04 Alarm5 Reservoir Low Level FLT 05 Alarm6 Reservoir Low Level WRN 06 Alarm7 Reservoir High Level WRN 07 Alarm8 Temp. Fuse Cutout FLT 08 Alarm9 Reservoir High Temp. FLT 09 Alarm10*1 10 Alarm11 Reservoir High Temp.
How to Order Symbol 2 1 01 06 2 AS 1 F E S K JIS Symbol Hexagonal lock nut Body size 2 3 4 1/8, 1/4 standard 3/8 standard 1/2 standard With seal Applicable tubing O.D.
Dimensions Dimensions 4-R .1(2.5) .47 (12) .98 (25) 1.63 (41.5) .67 (17) 1.34 (34) .94 (24) .65 (16.5) 1.02 (26) Panel nut Gasket .43 (11) .06 (1.5) .94 (24) 1.73 (44) .21 (5.4) Max. panel thickness .18 (4.5) .06 (1.6) 2.13 (54) Install the gasket underneath the panel or bracket (bonnet side). Tighten the panel nut by hand without the use of tools. 3
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Port size (IN, OUT port) Single Port size Rc size VR VPA3145 VPA3165 VPA3185 Symbol Body size 03 (10A) 3 8 (15A) 1 2 (20A) 3 4 (25A) 1 1 4 6 1 2 VH 04 06 10 12 14 20 8 1 2 1 Valve option VHS Nil For general purpose (32A) 1 4 1 (40A) 1 2 1 Body ported
Range Back Pressure SMC 22 8.0 -750mmHg~58psi 0~100C 0~30psi (60psi) 136 150 75 Height Width Operator Dia. 1 LVQ60 LQ Seal Locations N u t S e a l L o c k T ubing Support T aper Surface T u b i n g T r ap e zoidal T h re a d s I n s e rt Bushing Nut Lock U.S. Patent #5,996,636 Quadruple Seal Maximum leak protection. Up to 215psi @ 200C.
Magnetic Holding Power (lbs. force Series NCY2B Cylinder Theoretical Output 06, 410 100 o'15, 025,032, Q40 ^1100 3rooo I s00 I eoo g 7oo i m o 90 80 70 60 50 40 z 3 E .9 !
Magnetic Holding Power (lbs. force Series NCY2B Cylinder Theoretical Output 06, 410 100 o'15, 025,032, Q40 ^1100 3rooo I s00 I eoo g 7oo i m o 90 80 70 60 50 40 z 3 E .9 !
One-touch fitting 06 08 10 6 One-touch fitting 8 One-touch fitting 10 One-touch fitting Power supply cable Refer to the table below for selection of One-touch fittings.
Flow Direction Symbols on Body How to Order Meter-out type Meter-in type Indication symbol 2 1 01 06 2 AS 1 F E S K Hexagonal lock nut Body size 2 3 4 1/8, 1/4 standard 3/8 standard 1/2 standard With seal Symbol Applicable tubing O.D.
Symbol How to Order 2 1 01 06 2 AS 1 F E S K JIS Symbol Hexagonal lock nut Body size 2 3 4 1/8, 1/4 standard 3/8 standard 1/2 standard With seal Applicable tubing O.D. (mm) 04 06 08 10 12 Type 4 6 8 10 12 Port size Elbow Universal 2 3 01 02 03 04 R 1/8 R 1/4 R 3/8 R 1/2 Control type Meter-out Meter-in 0 1 With residual pressure release valve With One-touch fitting 15-9-36
One-touch fitting 06 08 10 6 One-touch fitting 8 One-touch fitting 10 One-touch fitting Power supply cable Refer to the table below for selection of One-touch fittings.
Symbol 23 04 06 08 10 12 16 Symbol 50 60 65 80 85 110 Applicable tubing O.D. mm 3.2 4 6 8 10 12 16 Applicable hose I.D.
How to Order Symbol 2 1 01 06 2 AS 1 F E S K JIS Symbol Hexagonal lock nut Body size 2 3 4 1/8, 1/4 standard 3/8 standard 1/2 standard With seal Applicable tubing O.D.
Pad Diameter: 06 (Flat + Bellows), Pad Styles: B (Bellows), Material: F (Fluoro Rubber), Rotating or Non-rotating: K (Non-rotating), Stroke: 25mm, Vacuum Entry: 06 (One-touch Fitting Ø6), Mounting Thread: A8 (M8X1)
Pad Diameter: 06 (Flat + Bellows), Pad Styles: U (Flat Style), Material: U (Urethane Rubber), Rotating or Non-rotating: K (Non-rotating), Stroke: 10mm, Vacuum Entry: 06 (One-touch Fitting Ø6), Mounting Thread: A8 (M8X1)