SMC Corporation of America
Elite Part Number Search
Search Results "Y44-04-D"

(mm) A 3.2 3.2 3.2 B 40 51 64 C 35 41 51 D 3.5 6 8 VH200 VH300 VH400 5-8-13 Series VH Dimensions: Panel Mounted VH41-02 to 04 VH41-06 ( ): Long handle type ( ): Long handle type 2 (A) 4 (B) 4 (B) 2 (A) 25 (32) 107.5 19 102 3 (R) 1 (P) 3 (R) 1 (P) 88 102 89 4-6.6 4-6.6 88 81 94 148(191) 144(191) 97(145) 97(145) 8 (10) M50 x 1.5 M50 x 1.5 8 (10) M8 x 1.25 M8 x 1.25 125(136) 123(134) 67

L O L G H F K J E D I A B C 2-4.5 A B C D E F G H I J K L Model 4 ZFC100-04 6 ZFC100-06 53.2 9.1 30 14.1 10 18 11.6 19.5 23 20 29 5/32" ZFC101-03 1/4" ZFC101-07 6 ZFC200-06 8 ZFC200-08 67 15.5 34 17.5 14 22 15.6 23.1 27 24 35 1/4" ZFC201-07 5/16" ZFC201-09 Element Replacement Element replacement procedure 1) Stop operation and reduce the filter's internal pressure to atmosphere. 2) Turn cover

Box 6165 Karachi 74000 Pakistan TEL: 021-243-9070/8449 FAX: 021-241-4589 ISRAEL (Distributor) Baccara Automation Control Kvutzat Geva 18915 Israel TEL: 04-653-5960 FAX: 04-653-1445 SAUDI ARABIA (Distributor) Assaggaff Trading Est. P.O. Box 3385 Al-Amir Majed Street, Jeddah-21471, Saudi Arabia TEL: 02-6761574 FAX: 02-6708173 16-14-21

Example 1) ASCII mode Received function code: 04(0 0100) ASCII code 30h, 34h Abnormal function code: 841000 0100 ASCII code 38h, 34h Example 2) RTU mode Receive function code: "04" (0 0100) Abnormal function code: "84" (1000 0100 2) Error Code Assign error code below. 01 : Function code of a command is outside the standard 02 : The specified address of register is outside the range. 03 :

L D 4 6 DP-04 DP-06 5.6 7.6 0.2 0.5 8 DP-08 8 9.6 0.8 10 DP-10 11.6 1.2 12 DP-12 13.6 1.6 Swivel elbow: L Effective orifice (mm2) Applicable tube O.D. (mm) Thread R(PT) H1 (Hex.) H2 (Hex.) H3 (Hex.) H4 (Hex.) Weight (g) Part No.

Thread R(PT) Port B min. port size Weight (g) D2 L1 L2 L3 P A Q1 Q2 M1 M2 1 8 1 4 3 8 6 4 KM14-04-06-01S-3 13 14 17 18 13 10.4 38.2 16 9.9 17 68 71.5 73.5 19 26 39 4.5 KM14-04-06-02S-3 12.8 10.4 KM14-04-06-03S-3 64 65.5 67.5 1 8 1 4 3 8 8 4 KM14-04-08-01S-3 31 69.5 70.5 71 73.5 76.5 77.5 17 19 15.5 10.4 38.2 16 11.1 18.5 39 6 KM14-04-08-02S-3 15.2 10.4 KM14-04-08-03S-3 1 8 1 4 3 8 8 6 KM14

Configuration One thermo-chiller for one master. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-12 Connection of RS-232C 3.3 Installation HRR Series 3-20 HRX-OM-X071 Chapter 3 Transport and Setting Up 3.4 Piping Piping port size Connect piping firmly.

Mounting/ Piping Equivalent tightening torque [Nm] KF 04 1.5 to 2.0 2 to 7 KF 06 1.5 to 2.0 3 to 8 KF 08 1.5 to 2.0 4 to 9 KF 10 1.5 to 2.0 6 to 9 KF 12 1.5 to 2.0 9 to 12 KF 04 1.5 2 to 4 KF 06 1.5 4 to 6 KF 08 1.5 6 to 9 KF 10 1.5 10 to 12 KF 12 1.5 10 to 12 Sleeve material Fitting size Appropriate tightening rotations Nylon 66 C2700 2.

(mm) Mounting screw L2 H2 D W1 H1 P L1 W2 W3 Model (Nominal x Length) 6 3.25 72.5 4.5 5.5 6 6.5 6.5 10 5 7.5 8 12 12 8 10 11 12 12 17 21 23 25 25 6 4 2.2 2.8 2.8 3.2 3.2 2 x 6 2.6 x 8 2.6 x 8 3 x 8 3 x 8 TM-04 TM-06 TM-08 TM-10 TM-12 7.5 9.5 91.5 5.5 77.5 6 7.5 77.5 6 15 9 93 12.5 6.5 4.5 16.3 8.8 14.3 7.5 12 12 10 8 9.8 How to Use 2.

SIZE PORT SIZE B G H D E WITH LAMP SWITCH DRAFT AIR OUTLET THERMOMETER EVAPORATION BALL VALVE BLOCK TERMINAL AUTO DRAIN F C VENTILATION VENTILATION [DIA.911]) (WIRE DIA.0.4 ENTRY HOLE POWER CORD DRAIN TUBE LENGTH39.4[1000] J N M K L P [4XDIA.13] 4XDIA.0.5 (SIZE OF RECOMMENDED BOLTM10) A B C D E F G H J K L M N P Q R Model Port Size Dimensions (inch [mm] ) 31.5 [800] 34.2 [868] IDFB55E 2 1.4

E F C (35.4[900]) J M N P L K H 4x0..5 (0.4[9~11mm] [4x13] [IDFB22E-11*(L=2800)] Unitinch [mm] A B C D E F G H J K L M N P 30.5 23.6 IDFB22E 1 [775] [600] 3.3 11.4 24.5 5.3 15.9 27.5 3.7 1.8 1 0.5 12.4 13.4 [290] [623] [134] [405] [698] [93] [46] [25] [13] [314] [85] [340] 26.8 33.7 IDFB37E 1/2 [855] [680] R IDFB55E/75E Q A B H G E D F C (0.4 (39.4[1000]) J L K M N P 4x0..5 [4x13]

Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts. Status (3): The circulating fluid temperature exceeds the threshold of "AS.06", but the alarm will not be generated as it has returned within the 600 sec range of the "AS.23: Range over detecting timer".

Also, take measures to prevent ingress of water and foreign matter from the breathing port of the diaphragm. 5-5-10 1 3 Port Air Operated Valve Series VGA342 How to Order SA 04 VGA342 A VA Port size Passage A Normally closed (N.C.) B Normally open (N.O.) Thread type Nil Rc F G N NPT T NPTF 04 1/2 06 3/4 10 1 SA VA JIS Symbol VM N.C. N.O.

Applicable series 1/4 3/8 1/2 VTA 02 03 04 VPA300 VPA500 VPA700 2 stations VGA 20 20 stations VPA VPA VPA3 VV3PA 3 3 42 04 02 Type 42/Individual exhaust Series 3 5 7 Thread type VPA300 VPA500 VPA700 Nil F N T Rc G NPT NPTF Port size Stations 02 Symbol Port size Applicable series 1/4 3/8 1/2 02 03 04 VPA300 VPA500 VPA700 2 stations 20 20 stations Manifold Option Description Part no.

Under the New Measurement Law, products for overseas use only (SI unit type for use in Japan). 02 1/4 X X X 03 3/8 X X 04 1/2 X 06 3/4 X X Options 10 1 X Nil B With bracket Handle / Bonnet material S Built-in Silencer (EXH port) A Flame resistant PBT B: Packed together S: Assembled for shipping B Aluminum 7 - (2) Double action type VHS 4 510 04 A BS Double Action Made to Order Body size

Left IN1(P) Piping VHS500-06 VHS501-06 VHS400-04 VHS401-04 VHS400-03 VHS401-03 VHS400-02 VHS401-02 Right IN1(P) 3 4 1 2 3 8 1 4 Port size Effective area (mm2)(CV) Weight (kg) 93(5.22) 57(3.20) 35(1.97) 21(1.18) 105(5.90) 76(4.27) 54(3.03) 35(1.97) 0.29 1(P)2(A) 2(A)3(R) 0.34 0.25 0.27 Left or right to the front face of the handle.

How to Order Air Output Port: KBV, KBZ (P. 15-2-113) 1 04 KB 1 V Elbow Module: KBV Elbow Socket Module: KBV T Connection thread Applicable tubing O.D. 4 Model Model Model Tube size/ Connecting female thread size Body size KBV1-04 KBV1-06 KBV2-06 KBV1-M5 KBV1-M6 KBV2-M5 M5 x 0.8 M6 x 1 M5 x 0.8 M6 x 1 6 KBV2-08 KBV3-08 8 KBV2-M6 KBV2-R1 KBV3-R1 KBV3-R2 KBV4-R2 KBV4-R3 1 8 Rc Branch Elbow Module

D Delta union v v Model Applicable tubing O.D.

04 C2 2 H 02 2 C4 4 L 04 4 N1 1/8" 01 1/8" N3 5/32" 03 5/32" L2 2 4 L4 4 LN1 1/8" LN3 5/32" -N KJL04-C1-N 10 Assy ZB1-FE3-A 30m ZA ** 10 1 0-101kPa15V 2%F.S ZA ZB1-SE1-A 3 -100100kPa15V 2%F.S.