Size: Body Ported, Operation: Internal Pilot Solenoid Valve, Port Size: 1+1/2, Thread: Rc(PT), Voltage: 110VAC 50/60HZ, Lead Wire: Conduit Terminal, Surge Suppressor: Z [Light & Surge Voltage Suppressor (Except Grommet)], Option: Bracket+Silencer
Size: Body Ported, Operation: Internal Pilot Solenoid Valve, Port Size: 1+1/2, Thread: Rc(PT), Voltage: 24VDC, Lead Wire: Conduit Terminal, Surge Suppressor: Z [Light & Surge Voltage Suppressor (Except Grommet)], Option: Bracket+Silencer
Size: Body Ported, Operation: Internal Pilot Solenoid Valve, Port Size: 2, Thread: Rc(PT), Voltage: 110VAC 50/60HZ, Lead Wire: Conduit Terminal, Surge Suppressor: Z [Light & Surge Voltage Suppressor (Except Grommet)], Option: Bracket+Silencer
Size: Body Ported, Operation: External Pilot Solenoid, Port Size: 1/2, Thread: Rc(PT), Voltage: 100VAC 50/60HZ, Lead Wire: Conduit Terminal, Surge Suppressor: Z [Light & Surge Voltage Suppressor (Except Grommet)], Option: Bracket+Silencer
Size: Body Ported, Operation: Internal Pilot Solenoid Valve, Port Size: 1/2, Thread: NPTF, Voltage: 24VDC, Lead Wire: Conduit Terminal, Surge Suppressor: Z [Light & Surge Voltage Suppressor (Except Grommet)], Option: Bracket+Silencer
Size: Body Ported, Operation: Internal Pilot Solenoid Valve, Port Size: 1, Thread: Rc(PT), Voltage: 110VAC 50/60HZ, Lead Wire: Conduit Terminal, Surge Suppressor: Z [Light & Surge Voltage Suppressor (Except Grommet)], Option: Bracket+Silencer
Size: Body Ported, Operation: External Pilot Solenoid, Port Size: 2, Thread: Rc(PT), Voltage: 100VAC 50/60HZ, Lead Wire: Conduit Terminal, Surge Suppressor: Z [Light & Surge Voltage Suppressor (Except Grommet)], Option: Bracket+Silencer
Size: Body Ported, Operation: External Pilot Solenoid, Port Size: 2, Thread: Rc(PT), Voltage: 110VAC 50/60HZ, Lead Wire: Conduit Terminal, Surge Suppressor: Z [Light & Surge Voltage Suppressor (Except Grommet)], Option: Bracket+Silencer
Size: Body Ported, Operation: Internal Pilot Solenoid Valve, Port Size: 1/2, Thread: Rc(PT), Voltage: 110VAC 50/60HZ, Lead Wire: Conduit Terminal, Surge Suppressor: Z [Light & Surge Voltage Suppressor (Except Grommet)], Option: Bracket+Silencer
Size: Body Ported, Operation: External Pilot Solenoid, Port Size: 1/2, Thread: Rc(PT), Voltage: 100VAC 50/60HZ, Lead Wire: Conduit Terminal, Surge Suppressor: None, Option: Bracket+Silencer
Size: Body Ported, Operation: External Pilot Solenoid, Port Size: 1/2, Thread: Rc(PT), Voltage: 24VDC, Lead Wire: Conduit Terminal, Surge Suppressor: Z [Light & Surge Voltage Suppressor (Except Grommet)], Option: Bracket+Silencer
Stations: 08 Stations, Port Size: B6 (Bottom Ported Elbow w/ΓΈ6 One-touch Fitting), SI Unit: N (PROFIBUS DP), End Plate: 2 [Power Supply w/M12 Connector (Max. supplied Current 2 A)], SI Unit Common: + COM (or None in the Case of w/o SI Unit), I/O Unit Stations: None, Option 1: B (w/Back Pressure Check Valve, All Stations), DIN Rail Length: None, Option 2: N (w/Name Plate)
Flow Rate Range: 501 (5 to 500 L/min), Thread Type: N (NPT), Port Size: 04 (1/2), Output Specifications: B (PNP; PNP), Option 1: N (No Lead Wire)
Flow Rate Range: 102 (10 to 1000 L/min), Thread Type: F (G), Port Size: 04 (1/2), Output Specifications: B (PNP; PNP), Option 1: N (No Lead Wire)
Actuation: Automatically Operated, Thread: NPT, Option: With Foot and Silencer
Actuation: Automatically Operated, Thread: Rc, Option: With Foot and Silencer
Actuation: Automatically Operated, Thread: G, Option: With Foot and Silencer
Flow Rate Range: 5 to 500 L/min, Thread Type: NPT, Port Size: 1/2, Output Specifications: PNP; PNP, Option 1: No Lead Wire, Unit Specifications: -, Option 2: -, Calibration Certificate: -
Flow Rate Range: 10 to 1000 L/min, Thread Type: G, Port Size: 1/2, Output Specifications: PNP; PNP, Option 1: No Lead Wire, Unit Specifications: -, Option 2: -, Calibration Certificate: -
Rated Flow Range: 10 to 1000 L/min, Thread Type: G, Port Size: 1/2, Output Specifications: Out 1: PNP; Out 2: PNP, Option 1: w/o Lead Wire and M8 Connector, Unit Specification: -, Option 2: -, Calibration Certificate: -