SMC Corporation of America
Elite Part Number Search
Search Results "VV2Q22-02-DO-00T"

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

Function: 3 (3 Position Closed Center), Piping: 3 (Body Ported), Exhaust: 0 (Individual), Low Wattage: None, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: DO (DIN Connector w/o Connector), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: Non-locking Push Type, A, B Port Size: 02 (1/4), Thread: F (G)

Function: 2 (2 Position Double), Piping: 3 (Body Ported), Exhaust: 0 (Individual), Low Wattage: None, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: DO (DIN Connector w/o Connector), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: Non-locking Push Type, A, B Port Size: 02 (1/4), Thread: T (NPTF)

Type of Actuation: 2 (2 Position Double), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: DO (DIN Connector w/o Connector), Lead Wire Length: None, Surge Suppressor: None, Manual Override: Non-locking Push Style, A, B Port Size: 02 (Body Ported 1/4), Thread: T (NPTF)

Model: 32, Orifice: 2 (2.2mm), Style: 0 (N.C., Single Unit), Option: C37, Seals: NBR, Class B, Suffix: Standard, Port Size: 02 (1/4), Thread: N (NPT), Voltage: 5 (24VDC), Electrical Entry: DO (DIN Terminal, w/o Connector, Gasket Included), Surge Suppressor: Non, Rectifier: None (for DC or AC Class H Coil)

/Single Unit), Solenoid Valve Option: Brass Body (Aluminum for Air Type), NBR Seal, Class B, Suffix: Standard, Port Size: 02 (1/4), Thread Type: Rc, Voltage: 5 (24VDC), Lead Wire: DO (DIN Connector without Connector)

Do not use the body A in a continuously rotating place. AQ Body B AS100P AS200P AS250P AS300P Model Rod and applicable tubing O.D.

Do not service or attempt to remove product and machinery/ equipment until safety is confirmed. 1. The inspection and maintenance of machinery/equipment should only be performed after measures to prevent falling or runaway of the driven objects have been confirmed. 2.

Do not service or attempt to remove product and machinery/ equipment until safety is confirmed. 1. The inspection and maintenance of machinery/equipment should only be performed after measures to prevent falling or runaway of the driven objects have been confirmed. 2.

NTJ-015A NT-02 NT-04 NT-05 12 M5 x 0.8 4 8 9.2 7.8 H B 20 5 13 15.0 12.5 M8 x 1.25 32, 40 8 22 25.4 21.0 M14 x 1.5 50, 63 11 27 31.2 26 M18 x 1.5 Electrical Wiring Output type The output signal of the stroke reading cylinder is A/B phase difference output (open collector output) as shown in the figure below.

Do not tighten the initial air supply flow any further than the minimum supply flow position, as this may result in component damage, or in increased time needed to attain a vacuum in the vacuum chamber due to a decline in the displacement capabilities of the gas accumulation part (bellows chamber). 1.

t m l For axis C shaped 5 0.030 0.060 0.030 0.060 0.040 0.076 0.040 0.076 0.040 0.076 0.050 0.093 0.050 0.093 0.065 0.117 12 16 20 25 32, 40 50, 63 80 100 4.8 4.8 7.6 9.6 9.6 13.4 17 21 12 16 20 25 32, 40 50, 63 80 100 IY-G012 IY-J015 IY-G02 IY-G03 IY-G04 IY-G05 IY-G08 IY-G10 M5 X 0.8 M6 X 1 M8 X 1.25 M10 X 1.25 M14 X 1.5 M18 X 1.5 M22 X 1.5 M26 X 1.5 NTJ-015A NT-015A NT-02

NTJ-015A NT-02 NT-04 NT-05 12 7.8 M5 x 0.8 9.2 8 4 H B 20 12.5 15.0 13 5 M8 x 1.25 32, 40 21.0 25.4 22 8 M14 x 1.5 50, 63 26 31.2 27 11 M18 x 1.5 Electrical Wiring Output type The output signal of the stroke reading cylinder is A/B phase difference output (open collector output) as shown in the figure below.