Part number Description Note ZS-40-A Lead wire with M8 connector Length: 3 m ZS-42-A Bracket With mounting screws for PFMC7501/7102 (M3 x 5, 2 pcs.) ZS-42-B Bracket With mounting screws for PFMC7202 (M3 x 5, 2 pcs.)
10, 16, 20 (mm) Bore size (mm) Stroke range (mm) A B FD FT FV FX FV 10 10 to 40 49.5 31.5 4.5 5.5 30 45 FX FT L B + Stroke 16 10 to 60 54 34 6.6 8 39 48 FZ 20 10 to 60 57.5 37.5 6.6 8 42 52 A + Stroke 2-FD 25 10 to 50,75,100 64 42 5.5 8 48 56 30 10 to 50,75,100 70.5 48.5 5.5 8 54 62 25, 30, 40 40 10 to 50,75,100 72 50 6.6 9 67 76 Bore size (mm) FZ L M FV 10 55 18 FX FT L B + Stroke 16 60
A A1 E1 L1 MM RR1 U1 NZ L 42 56 16 20 22 28 30 40 M14 x 1.5 M18 x 1.5 12 16 14 20 42 56 14 18 22 28 30 40 M14 x 1.5 M18 x 1.5 12 16 14 20 I-G04 I-G05 Y-G04 Y-G05 36 41.6 +0.5 +0.3 +0.058 0 -0.3 -0.5 +0.058 0 44 50.6 +0.5 +0.3 +0.070 0 Knuckle pin and snap ring are included. -0.3 -0.5 +0.070 0 Knuckle Pin (Also used as double clevis pin) Rod End Nut d d Dd9 C m m l L t t H B Material: Carbon
A A1 E1 L1 MM RR1 U1 NZ L CNS 42 56 16 20 22 28 30 40 M14 x 1.5 M18 x 1.5 12 16 14 20 I-G04 I-G05 Y-G04 Y-G05 +0.5 +0.3 42 56 14 18 22 28 30 40 M14 x 1.5 M18 x 1.5 12 16 14 20 36 41.6 +0.058 0 -0.3 -0.5 +0.058 0 +0.5 +0.3 44 50.6 +0.070 0 Knuckle pin and snap ring are included. -0.3 -0.5 +0.070 0 CLS CLQ MLGP Knuckle Pin (Common with double clevis pin) Rod End Nut RLQ MLU d d Dd9 ML1C C m
Auto Switch Mounting Height (mm) D-A7H D-A80H D-F7 D-J79 D-F7W D-J79W D-F7BA D-F79F D-F7NT Auto switch model D-F7V D-F7WV D-F7BAV D-J79C D-A79W D-A9V D-M9V D-M9WV D-M9AV D-A7 D-A80 D-A73C D-A80C Bore size (mm) U 20.5 25.5 27 30.5 36.5 40 U 20.5 25.5 29 32.5 38.5 42 U 20.5 25.5 32.5 36 42 48.5 U 26.5 31.5 38.5 42 48 54.5 U 23 28 35 38.5 44.5 51 U 26 31 38 41.5 47.5 54 U 22 27 34 37.5 43.5
TU TV TW TX TY TZ B1 H1 Material: Carbon steel (mm) CG-020-24A CG-025-24A CG-032-24A CG-040-24A CG-050-24A CG-063-24A CG-080-24A CG-100-24A 8d9 10d9 12d9 14d9 16d9 18d9 18d9 22d9 0.040 0.076 0.040 0.076 0.050 0.093 0.050 0.093 0.050 0.093 0.050 0.093 0.050 0.093 0.065 0.117 (18.1) (35.8) 42 42 48 56 64 74 72 93 16 20 22 30 36 46 85 100 28 28 28 30 36 46 45 60 38.3 Part no.
: Base mounted (A, B port side ported) Applicable solenoid valve VK3140-(-Q) VK334-(-Q) Type VK3140 VV5K3 05 42 01 Type VK334 VV061 Solenoid direction Valve stations 01 1 station Applicable blanking plate assembly VK3000-7-1A Solenoid on opposite side of A and B port VV100 Nil A port: Rc 1/8 B port: Rc 1/8 P port: Rc 1/8 R port: Rc 1/8 Thread type Type S42 20 20 stations Solenoid on same
Hold down again for 1sec. or longer after interval No.IP8S-OM09 59 Mode button 1s Set button 1s or Mode button 1s Set button 1s or Mode button 1s Mode button 1s Set button Set button 1s 1s Fig. 42-1 Mode button 1s Set button 1s or Lower limiter Upper limiter Fig. 42-2 Mode button 1s Set button 1s Alarm setting Fig. 42-3 No.IP8S-OM09 60 Possible to select set alarm 2 mode(on
{(16 A) (54 B) (88 C)} 2304 A: Number of remote I/O stations 64 B: Number of remote device stations 42 C: Number of local stations 26 (d) When the number of units connected is 4, station numbers can be set as shown below.
DZ 8 10 10 14 CZ 8 10 10 14 DY 9 11 13 16 CX 9 11 13 16 DX 18 22 26 32 CT 9.5 11 14 17 DT 9.5 11 14 17 CR 5.3 6.4 8.4 10.5 DR 5.3 6.4 8.4 10.5 CL 26 42 54 64 DL 26 42 54 64 7 Plate Cylinder with Lock Series MLU Single knuckle joint Double knuckle joint MM C (R1) Sphere, ball R (R1) MM NDH10 NDH10 A1 A1 NX+0.4 +0.2 E1 NX -0.2 -0.4 NZ E1 U1 U1 L1 NO NL L1 NO NL (mm) Part no.
CD-MU02 CD-MU03 CD-MU04 CD-MU05 DZ 8 10 10 14 CZ 8 10 10 14 DY 9 11 13 16 CX 9 11 13 16 DX 18 22 26 32 CT 9.5 11 14 17 DT 9.5 11 14 17 CR 5.3 6.4 8.4 10.5 DR 5.3 6.4 8.4 10.5 CL 26 42 54 64 DL 26 42 54 64 Part no. MU-C02 MU-C03 MU-C04 MU-C05 Part no.
CD-MU02 CD-MU03 CD-MU04 CD-MU05 DZ 8 10 10 14 CZ 8 10 10 14 DY 9 11 13 16 CX 9 11 13 16 DX 18 22 26 32 CT 9.5 11 14 17 DT 9.5 11 14 17 CR 5.3 6.4 8.4 10.5 DR 5.3 6.4 8.4 10.5 CL 26 42 54 64 DL 26 42 54 64 Part no. MU-C02 MU-C03 MU-C04 MU-C05 Part no.
If the security code is forgotten 42 Troubleshooting 43 Specification 50 Specifications 50 Dimensions 52 -1No.PS-OMM0003-J Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.
BA -32 BA -04 BM1 -01 BM1 -02 BM1 -32 BM1 -04 Intermediate strokes and short strokes other than the above are produced upon receipt of order.
mA), 0.5 W DC (21 mA) (4) 24 VDC Power consumption (Current) 1 W DC (83 mA), 0.5 W DC (42 mA) (4) 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) 12 VDC Metal seal Rubber seal Note 1) Use dry air to prevent condensation when operating at low temperatures.
Port size VCB2 VCW20-12-01A 34 40 25 30 12.8 12.8 5 4.5 6 13 1/8, 1/4 VCW30-12-02A 42 52 30 40 19 19 6 5.5 7 19 1/4, 3/8 VCB3 VCW30-12-04A Note 1) 48 56 36 44 23 23 6 5.5 7 23 1/2 VCW40-12-02A 42 52 30 40 23 23 6 5.5 7 19 1/4, 3/8 VCB4 VCW30-12-04A Note 1) 48 56 36 44 23 23 6 5.5 7 23 1/2 VCW40-12-06A 56 65 44 53 28.2 28.2 6 5.5 7 26 3/4 2 mounting screws (for mounting bracket) are included
Valve model Port size L J H G F E D C A B VCW20-12-01A VCB2 1/8, 1/4 13 6 4.5 5 12.8 12.8 30 25 40 34 VCW30-12-02A 1/4, 3/8 19 7 5.5 6 19 19 40 30 52 42 VCB3 VCW30-12-04A 1/2 23 7 5.5 6 23 23 44 36 56 48 VCW40-12-02A 1/4, 3/8 19 7 5.5 6 23 23 40 30 52 42 VCW30-12-04A VCB4 1/2 23 7 5.5 6 23 23 44 36 56 48 VCW40-12-06A 3/4 26 7 5.5 6 28.2 28.2 53 44 65 56 Two mounting screws (for mounting
VR1210-01 Model VR1220-02 1.0 MPa 0.05 MPa Max. operating pressure Min. operating pressure Min. pressure differential 0.05 MPa 5 to 60C (No freezing) SA Ambient and fluid temperature Effective area Port size Weight 7 mm2 15 mm2 VA 1 8 1 4 24 g 45 g SA How to Order VA 01 0 VR12 1 VM 01 Port size VR 1 8 1 4 02 JIS Symbol VH Nil Thread type VHS Rc NPT N G F standard 1 Body size 1 8 Construction
Beneath the manifold base part number, enter the valve and option part numbers to be mounted. 6 Series V100 Common SUP/Common EXH Type S41 How to Order Applicable solenoid valve Note) VV100 S41 05 M5 V114V114AV124V124A2 port size Stations 02 M5 M5 x 0.8 2 stations 2 Applicable blank plate assembly V100-77-1A 1 20 20 stations 3 2 Port 1 M5 x 0.8 Port 3 M5 x 0.8 Port 2 M5 x 0.8 Note) V114(A
PA03 02: LEC-MR-RB-032 03: LEC-MR-RB-12 Set this parameter to enable the absolute position detection system. For details, refer to "LECSN-T Operation Manual, Chapter 12.