-M3 X 0.5 (Piping port) 33 36 (Non-locking) Manual override B P R R 7 7 SlA 36 2 35 7 13.5 28.5 15 A 21 R2 P R1 VlA 13 1 (Bleed port) 11 10 4 15 10 10 5-M5 X 0.8 (Piping port) 8.2 14 14 15 Bracket VM/VR VH 2 position double: SYJA3220-M3(-F) 2 position double: SYJA3240-M5 10 9 36 7.1 2-M3 X 0.5 (Pilot port) 10 1.8 4 A B (Mounting holes) 3.2 21.5 1.5 22 7 8.2 2.5 (Mounting holes for manifold

x 0.5 3.5 M3 x 0.5 M3 x 0.5 16 50.5 10.8 24.4 9.4 25 9.5 2H9 2 M3 x 0.5 4.8 20 22.5 2H9 2 11 2H9 2 M3 x 0.5 3.5 M4 x 0.7 M3 x 0.5 18 56 13.4 26.2 11.3 28 10 2H9 2 M3 x 0.5 5.3 21 24.5 2H9 2 11.5 2H9 2 M3 x 0.5 3.5 M5 x 0.8 M3 x 0.5 20.5 60 15.2 31 11.8 30.5 12 2H9 2 M3 x 0.5 5.3 25 27 2H9 2 13.5 2H9 2 M4 x 0.7 4.5 M6 x 1 M5 x 0.8 23 73.5 15.4 37.4 14.9 34.5 14 3H9 3 M4 x 0.7 6.5 29 32.5 3H9

Port size Applicable model Flow rate (l/min) Symbol 3000 6000 12000 10 14 20 1 11/2 2 PF2A703H PF2A706H PF2A712H Specifications PF2A703H PF2A706H Dry air Heater type 300 to 6000 l/min PF2A712H Model Measured fluid Detection type Flow rate measuring range Note 1) 600 to 12000 l/min 10 l/min 150 to 3000 l/min 5 l/min Minimum setting unit Note 1) l/min, CFM l, m3, m3 x 103, ft3, ft3 x 103

Unit switching Real-time switch output ( ) For air Hysteresis mode Display Real-time flow rate l/min Accumulated flow l ON YES CFM x 10-2, CFM x 10-1 ft3 x 10-1 OFF P-1 P-2 High flow rate CFM=ft3/min "P" Window comparator mode H : Hysteresis High Flow Rate Type (For Air) H H Display Real-time flow rate l/min Accumulated flow l, m3, m3 x 103 ON NO OFF P-1 P-2 ft3, ft3 x 103, ft3 x 106 CFM

Critical pressure 0.6 0.5 Sonic 0.5 0.4 0.4 0.3 0.3 0.2 0.2 0.1 0.1 JSXD30 Port size 1/4 JSXD30 Port sizes 3/8, 1/2 JSXD40 Port size 3/8 JSXD40 Port size 1/2 JSXD50 Port size 3/4 JSXD60 Port size 1 10 1000 2000 3000 10 1000 2000 3000 4000 15 2000 4000 6000 8000 15 2500 5000 7500 10 20 5000 10 15000 25 5000 10 15000 20 Flow rate Q [L/min (ANR)] For Air (Orifice diameter: 35 mm, 40 mm, 50 mm

Unit switching Real-time switch output ( ) For air Hysteresis mode Display Real-time flow rate l/min Accumulated flow l ON YES CFM x 10-2, CFM x 10-1 ft3 x 10-1 OFF P-1 P-2 High flow rate CFM=ft3/min "P" Window comparator mode H : Hysteresis High Flow Rate Type (For Air) H H Display Real-time flow rate l/min Accumulated flow l, m3, m3 x 103 ON NO OFF P-1 P-2 ft3, ft3 x 103, ft3 x 106 CFM

R Q2 B P C F(h9) D G1 G2 J K L M N Q1 E(g6) Q3 Model A 90 180 270 M5 M3 CRB1BW10-lS CRB1BW10-lSE CRB1BW15-lS CRB1BW15-lSE CRB1BW20-lS CRB1BW20-lSE CRB1BW30-lS CRB1BW30-lSE 3.4 (5.5) 5 8.5 5 11 9 14 10 15.5 25 9.5 25 10 25 13 25 14 M3 (6) 0 0.036 15 24 8 0.004 0.012 9 14 3 1 5 9 0.5 29 4 M3 M3 (5) M5 M3 3.4 (6) M3 (10) 0.004 0.012 0 0.043 20 29 9 12 18 5 4 1.5 6 10 0.5 34 M3 M4 (7.5) 4.5

11) (0.5) 10 5 5 2-1 (Bleed port) 10 10 7 7 2-1 (Bleed port) M3 x 0.5 (Piping port) 28 M5 x 0.8 (Piping port) 3 position closed center/exhaust center/pressure center SYJA3 20-M3(-F) 3 position closed center/exhaust center/pressure center SYJA3 40-M5 3 4 5 3 4 5 7.1 9 10 2-M3 x 0.5 (Pilot port) 1.8 10 4 A B 1.5 7 8.2 19 2-M3 x 0.5 (Pilot port) (For mounting) 2-3.2 22 3 49 2.5 (For mounting

B M3 x 0.5 (Piping port) 1.5 1.5 33 36 Manual override B P R R (35) 7 7 36 (2) 7 (13.5) 28.5 15 A 1 (Bleed port) 21 R2 P R1 13 4 8.2 15 10 10 10 M5 x 0.8 (Piping port) 11 14 14 15 (Bracket) 2 position double: SYJA3220-M3(-F) 2 position double: SYJA3240-M5 10 9 36 7.1 2 x M3 x 0.5 (Pilot port) 10 1.8 4 A B (For mounting) 2 x 3.2 1.5 1.5 22 7 8.2 2.5 (For manifold mounting) 2 x 1.8 2 x M3 x

] [C] [g/m3] [mg/m3] 0 As specified by the equipment user or supplier and more stringent than class 1 1 20 400 10 70 0.01 2 40 6000 100 40 0.1 3 90 1000 20 1 4 10 +3 5 5 10 +7 6 0 < Cp 5 +10 7 5 < Cp 10 Cw 0.5 8 0.5 < Cw 5 9 5 < Cw 10 x Cp > 10 Cw > 10 > 5 [How to Perform a Test to Check the Performance] ISO 12500, which sets out the test method to

10 10 10 10 10 58 70 87 NN 2 2 2 2 3 4 5 6 7 H 45 45 45 55 35 35 35 38 44 G 15 15 15 15 15 19 37 41 19 N 4 4 4 4 6 6 6 8 8 HA 35 35 35 35 35 70 70 76 88 NA 2 2 2 2 2 2 4 4 4 FF 40 40 40 50 35 60 70 70 80 GA 25 25 25 35 50 54 107 155 195 KA 169 223 275 13-/22-MXS20L-10 13-/22-MXS20L-20 13-/22-MXS20L-30 13-/22-MXS20L-40 13-/22-MXS20L-50 13-/22-MXS20L-75 13-/22-MXS20L-100 13-/22-MXS20L-125

2-M3 x 0.5 (Plug: M-3P) 6 (fitting seat surface dimension) 170.05 M3 x 0.5 Vacuum suction port Stroke: S M 1 Mounting base side B D Piping port 2-M3 x 0.5 A 5 5.5 A 3.2 J 2.4 Z Section AA 3.5 Depth 2 2.5 +0.030 0 7 +0.030 0 Depth 2 2.5 Q QL 11-/22-MXPJ6-10 4M3 x 0.5 depth 3 F (mm) E F H J M Q QL S Z Model 23 25 38 27 37 28 8 5 44 11-/22-MXPJ6-51 30 35 53 42 47 37 11 10 59 11-/22-MXPJ6-10

75mm stroke V = 200mm/s 20 20 25 10 10 25 Load weight m (kg) Load weight m (kg) 20 20 5 5 16 16 1 10 50 100 200 1 10 50 100 200 Eccentric distance l (mm) Eccentric distance l (mm) MGPL32 to 63 7 25mm stroke V = 200mm/s 8 Over 25mm stroke V = 200mm/s 100 100 63 63 50 50 50 50 Load weight m (kg) Load weight m (kg) 40 40 32 32 10 10 5 10 50 100 200 5 10 50 100 200 Eccentric distance l (mm)

B All Ports: One-touch Fitting Model D1 D2 D3 d1 d2 d3 M1 M2 M3 L1 L21 L3 L4 A B C E F G1 J1 K1 N1 P1 Q1 ZH05DA-06-06-06 10.4 10.4 10.4 6 6 6 13.3 13.3 13.3 51.8 34.9 19.4 18.4 11 14 6 3.2 5.5 20 17 4.2 3.2 28 9.6 ZH07DA-06-06-06 55 ZH10DA-06-06-08 13.2 8 14.2 61.7 ZH13DA-08-10-10 13.2 15.9 15.9 8 10 10 14.2 15.6 15.6 71.8 43.9 22.4 24.4 17 20 9 4.3 7.8 27 22 4.2 35 12 ZH15DA-08-10-10 83.6

Round type Flat type 5.5 NTP-006 CJ-CR006 CJ-CF006 6.4 1.8 M3 x 0.5 6 6 8 11 6 M3 x 0.5 5 6 8 7 NTP-010 CJ-CR010 CJ-CF010 8.1 2.4 M4 x 0.7 10 8 10 13 10 M4 x 0.7 6 8 10 8 NTP-015 CJ-CR016 CJ-CF016 9.2 3.2 M5 x 0.8 15 10 12 15 15 M5 x 0.8 7 10 12 6-2-13 8 Pin Cylinder Single Acting, Single Rod, Single Return Series CJP 6, 10, 15 How to Order A short stroke miniature cylinder with a shorter

20 CY 15 10 MG 0.1 10 CX 0.1 6 6 D-X 0.03 5 5 10 20 30 40 50 100 10 20 30 40 50 100 20Overhang L (mm) Overhang L (mm) Graph (4) V = Up to 800 mm/s (Up to 700 mm/s for 15, 20) Data CXSJM CXSJL Graph (3) V = Up to 600 mm/s CXSJM CXSJL 20 32 0.5 25 1 15 20 0.5 15 Weight m (kg) 10 0.1 10 0.1 6 6 10 20 30 40 50 100 5 10 20 30 40 50 100 5 Overhang L (mm) Overhang L (mm) Note) V = 700 mm/s for 15

Round type Flat type 5.5 NTP-006 CJ-CR006 CJ-CF006 6.4 1.8 M3 x 0.5 6 6 8 11 6 M3 x 0.5 5 6 8 7 NTP-010 CJ-CR010 CJ-CF010 8.1 2.4 M4 x 0.7 10 8 10 13 10 M4 x 0.7 6 8 10 8 NTP-015 CJ-CR016 CJ-CF016 9.2 3.2 M5 x 0.8 15 10 12 15 15 M5 x 0.8 7 10 12 6-2-13 8 Pin Cylinder Single Acting, Single Rod, Single Return Series CJP 6, 10, 15 How to Order A short stroke miniature cylinder with a shorter

10 to 32 Graph (3) V = 200 mm/s Graph (4) V = 400 mm/s 4 20 3 10 32 5 25 1 Weight m (kg) Weight m (kg) 32 20 25 0.5 1 20 15 0.5 15 10 CXSM CXSL CXSM CXSL 10 5 0.1 5 0.1 10 20 30 40 50 100 10 20 30 40 50 100 Overhang l (mm) Overhang l (mm) Graph (5) V = 600 mm/s Graph (6) V = 700 mm/s (800 mm/s for 10) 2 0.6 20 32 25 0.4 1 15 20 Weight m (kg) Weight m (kg) 0.5 15 0.2 10 10 CXSM CXSL CXSM

(Through) Note 1) 3 +0.05 0 depth 1.5 6 3.5 10 3 +0.03 0 depth 1.5 Note 1) (Through) 2 x M1.7 x 0.35 thread depth 1.5 42.5 27.5 8 1.5 3 9.5 Vacuum port M3 x 0.5 Operating port 2 x M3 x 0.5 (Plugged when the product is not a symmetric type.)