N.O. 10-SYJ714M 140 (80) 1/8 Base mounted (with sub-plate) 10-SYJ724M 135 (75) 136 (76) 157 (97) 10-SYJ714M 1/4 10-SYJ724M Note) Value for DC. Add 3 g for AC. ( ): Without sub-plate. 627 3 Port Pilot Solenoid Valve 10-SYJ700 Note) AC-type models that are CE-compliant have DIN terminals only.
fluid temperature 2-position single, double 4-position dual 3 port valve 5 Max. operating frequency (Hz) 3-position 3 Non-locking push type, Push-turn locking slotted type, Push-turn locking lever type Manual override (Manual operation) Pilot exhaust method Main/Pilot valve common exhaust Lubrication Not required Mounting orientation Unrestricted Impact/Vibration resistance (m/s2) Note) 150
Local Area: (800) 258-9200-www.stevenengineering.com Model/Self-standing Type AMD1000 Model 8000 AMD800 24000 AMD900 40 Port size (Nominal size B) 2B flange 2B, 3B, 4B flange 4B, 6B flange Weight (kg) 100 220 430 Rated flow (l/min (ANR)) Model/Piping Support Type Model 8000 AMD801 24000 AMD901 Rated flow (l/min (ANR)) Port size (Nominal size B) 2B flange Weight (kg) 50 2B, 3B, 4B flange 140
Applicable dryer Capacity Model Inlet voltage Outlet voltage A B C D E F Weight (kg) 200, 220 230, 240 VAC (50 Hz) 200 to 260 VAC (60 Hz) 100 VAC (50 Hz) 100 to 110 VAC (60 Hz) Single phase Single turn IDF-TR500-2 IDF1E-10 to 8E-10 IDU3E-10, 4E-10 500 VA 118 140 150 70 112 142 6 IDF-TR500-3, 4 C VOLUTAGE SELECTOR FUSE B OUT PUT IN PUT E D 4-F A Input cord 2 m Transformer part no.
(Displays 0 when the value is (Displays 0 when the value is below 60 L/min) below 120 L/min) 70 to 1050 L/min 140 to 2100 L/min 7.0 0 to 7%F.S. (Displays 0 when the value is (Displays 0 when the value is below 70 L/min) below 140 L/min) 80 to 1050 L/min 160 to 2100 L/min 8.0 0 to 8%F.S.
160 180 Timemin. 30 Ambient temperature25 Recirculating fluidGALDEN HT200 Recirculating fluid level180 (At recirculating fluid temp. 25) Cooling water flow rate3L/min Shut out from outside with a lid (styrofoam) Recirculating fluid temperature 25 R 20 15 10 5 Cooling water 25 Cooling water 35 0 -5 -10 Cooling water 10 -15 -20 0 20 40 60 80 100 120 140 160 180 Timemin.
Comm Format: Data-SINT Comnection Parameters Instance Size Input 100 256 Output 150 256 Configuration 1 0 It is not necessary to set Connection and ModuleInfo. RSLogix5000TM is a registered trademark of Rockwell Automation. 20 - 5. External connection 5. 1 CN4: Power supply connector Connect the power supply. The gateway unit and the controller (LEC) should have the common 0V line.
52 140 41 81 105 13 2 2 5-5-26
114 5 166 140 6 192 166 7 218 192 8 244 218 9 270 244 10 296 270 [ ]: With light/surge voltage suppressor 4-7-7 8 Series VT307 Dimensions: Individual Exhaust (Interchangeable with VT301 for mounting) VV307-01-3--F P = 26 (Applicable cable O.D.)
XB6 XB6 XB6 e w Magnetic Holding Force (Ibf) (C) (F) 20 (68) 80 (176) 100 (212) 120 (248) 140 (284) 160 (320) 60 (140) 40 (104) (mm) 63 50 40 32 25 20 15 10 6 Bore size Ambient temperature (inch nominal) 2-1/2" 2" 1-1/2" 1-1/4" 1" 3/4" 5/8" 3/8" 1/4" Holding force (at 302F) When using with the operating temperature fluctuated between 50C (122F) or less and 100C (212F) or more, the operating
Fluid 1.0 MPa (0.7 MPa) (3) Maximum operating pressure Valve specifications Solenoid specifications Single 0.20 MPa 0.15 MPa Min. operating pressure Double 0.15 MPa 0.15 MPa 3 position 0.20 MPa 0.15 MPa (1) (1) 5 to 50C 10 to 50C Ambient and fluid temperature Lubrication Not required Plug lead unit Manual override Push type/Locking type (Tool required) Option Shock/Vibration resistance 150
Consult factory for strokes less than 10mm. 6.1 16 External Feedback Lever (IP6000 type) Stroke Order Code Unit Number Size M Size N P368010-20 5 9/10" 4 9/10" 10~85 mm (Nil) 5 M N P368010-21 7 2/3" 4 1/3" 35~100 mm (E) P368010-22 10 4/5" 4 1/3" 50~140 mm (F) DIMENSIONAL DRAWINGS S E R I E S I P 6 0 0 0 / I P 6 1 0 0 IP6000 TYPE: LEVER TYPE FEEDBACKNO TERMINAL BOX (FM Model) IP6000 TYPE:
Flange: 32F, 40F, 50F LVQ J (Valve open) LQ Indicator (Option) LVN Pilot port TI/ TIL PA PAX PB 4 x 2-18 mounting hole Applicable flange Pilot port Rc A B C D E F G H J Model 8 10 12 50 40 32 1 8 1 4 1 4 VND50D-32F VND60D-40F VND70D-50F 130 150 180 211.5 227 251 135 140 155 135 147 163.5 20 24 24 100 105 120 36 42 54 12 12 14 17-4-41 6 Series VND Precautions Be sure to read before handling
Ambient temperature range should be 14-140"F 1-10^60'C). Please contact SIVIC for cases other than this ranoe. e Load on Diston rod Pay special attention to the lact that the load of piston rod should always be aligned parallel with lhe cylinder axis.
r6 on "A" pllot: mhu510 {0.09 (0.89) {0.69) 125 PS|G I .3Kgl/cmr) M6)dmum Ambl6nt T6moraturt I 140. F (60. C) Msdra: Alr 0ubrlcted or oll lr3), any non.flammsbtG, non.lorlc, non{ollo3iva oasE oxcol oxvo6r,.
Non-locking push type Unrestricted 150/50 m/s2 Make sure that dust and/or other foreign materials do not enter the valve from the unused port (e.g. exhaust port).
Ambient temperature range should be 14-140"F 1-10^60'C). Please contact SIVIC for cases other than this ranoe. e Load on Diston rod Pay special attention to the lact that the load of piston rod should always be aligned parallel with lhe cylinder axis.
r6 on "A" pllot: mhu510 {0.09 (0.89) {0.69) 125 PS|G I .3Kgl/cmr) M6)dmum Ambl6nt T6moraturt I 140. F (60. C) Msdra: Alr 0ubrlcted or oll lr3), any non.flammsbtG, non.lorlc, non{ollo3iva oasE oxcol oxvo6r,.
K (D) 2 x Port size DS: DIN terminal DZ: DIN terminal with light GS: Grommet with PCB CS: Conduit U V E Applicable cable 6 to 12 U E 300 U E G1/2 500 NPT1/2 T T T DN: DIN terminal without connector WN: M12 connector E U E U T T [mm] Size Port size A B C D E F I K L M 70 1 1/4 132.6 26.5 42 125 21 51.5 43.5 67.5 57.5 53 80 1 1/2 139.3 30 42 132 21 54.5 46.5 72 60 60 90 2 150.3 35.5 42 150
5 ON 1A OFF Power supply switch COM FG AC2 AC1 SV9 SV10 SV7 SV8 SV5 SV6 SV3 SV4 SV1 SV2 5 140 5 Output terminal block Common terminal block 4 x 4.5 Power supply terminal block 34 or less 38 or less 26 10 or more JSXFA Series / Glossary of Terms Pressure Terminology Other 1.