SMC Corporation of America
Elite Part Number Search
Search Results "RDQB32-40-M9P"

weight m(kg) Larger than 75st Load weight m(kg) 40 50 100 Larger than 50st 50st 25st 30 25, 50st 20 50 40 10 30 5 4 3 2 20 1 10 20 30 40 50 100 200 300 1 2 3 4 5 10 20 304050 100 200 300400 Eccentric distance l (mm) 10 400 Eccentric distance l (mm) Allowable side load F(N) 1 N: Approx. 0. 102 kgf F Stroke (mm) Bore size (mm) Model 25 50 75 100 125 150 175 200 MGTM 140 151 162 176 193 212

Bore size 32 mm 32 40 mm 40 50 mm 50 63 mm 63 Action Double acting D Applicable Auto Switch/Refer to page 12-13-1 for further information on auto switches.

Arm Load A CRB2 Displacement CRB1 MSU MSZ10A MSZ20A CRJ CRA1 300 CRQ2 MSQ MSZB10A (Basic type) 400 MSZ MSZ MSZA20A (Basic type) Displacement m Displacement m 250 CRQ2X MSQX MRQ 350 200 40 190 40 30 30 MSZA10A (High precision type) MSZA20A (High precision type) 20 20 10 10 50 40 30 20 10 0 30 25 20 15 10 5 0 Load N Load N MSZ50A MSZ30A 350 300 300 250 250 MSZB30A (Basic type) MSZB50A (Basic

Bore size 32 mm 32 40 mm 40 50 mm 50 63 mm 63 Action Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Double acting D Applicable Auto Switch/Refer to page 12-13-1 for further information on auto switches.

the opposite side) G 40 mm Adjustment bolt Bumper bolt Shock absorber/ Adjustment bolt (metal ended): Plate A side Standard stroke Refer to page 1501 for the standard strokes.

(Nil) CG3 CG3 Bore size G: Same rod end dimensions (A, AL, H) as CG1 series. 20 25 32 40 50 63 80 100 50 mm 63 mm 80 mm 100 mm 20 mm 25 mm 32 mm 40 mm JMB Number of auto switches Mounting brackets are shipped together, (but not assembled). MB AL Nil S n 2 pcs. 1 pc. n pcs.

DBore size 20 25 32 40 Without auto switch (built-in magnet) Nil Auto switch type 20 mm 25 mm 32 mm 40 mm Select applicable auto switches from the table below. Cylinder stroke (mm) Refer to the standard stroke table on page 298. Applicable Auto Switches/Refer to pages 431 to 490 for further details on each auto switch.

CM2 A B Z 40 150 CDM2 With auto switch M9BW 150 A B 40 Z Port thread type Number of auto switches Rod end bracket With auto switch (Built-in magnet) Nil Rc TN NPT TF G Nil None V Single knuckle joint W Double knuckle joint Mounting Nil 2 pcs. S 1 pc. n n pcs.

Air Cylinder Double Acting, Single Rod JMB Series 32, 40, 45, 50, 56, 63, 67, 80, 85, 100 How to Order With auto switch JMDB 32 50 M9BW B With auto switch (Built-in magnet) Not available without magnet Number of auto switches Nil 2 S 1 3 3 n n Mounting B Basic Auto switch Bore size Nil Without auto switch 32 32 mm 40 40 mm 45 45 mm 50 50 mm 56 56 mm 63 63 mm 67 67 mm 80 80 mm 85 85 mm 100

Air Cylinder: Single Rod Series MB 32, 40, 50, 63, 80, 100, 125 How to Order 50 L 32 MB With auto switch MDB M9BW L 32 50 Made to Order For details, refer to page 291.

Lead wire length (m) Applicable load Pre-wired Indicator light Load voltage Auto switch model Applicable bore (mm) Wiring (Output) Special function Electrical entry Type AC 3 (L) 1 (M) 5 (Z) 0.5 (Nil) None (N) DC connector 20, 25 40, 50 32 M9N M9P M9B H7C M9NW M9PW M9BW H7BA H7NF 3-wire (NPN) IC circuit 5 V, 12 V 3-wire (PNP) Grommet Reed switch Solid state switch 2-wire 12 V Connector Yes

Mounting bracket Description 20 25 32 40 50 63 80 100 20 to 40 : Foot x 2, Mounting nut x 1 Axial foot 2 Note) RHC-L020 RHC-L025 RHC-L032 RHC-L040 RHC-L050 RHC-L063 RHC-L080 RHC-L100 50 to 100: Foot x 2, Bracket mounting bolt x 8, Spring washer x 8 20 to 40 : Flange x 1 1 Flange RHC-F020 RHC-F025 RHC-F032 RHC-F040 RHC-F050 RHC-F063 RHC-F080 RHC-F100 50 to 100: Flange x 1, Bracket mounting

Bore size 20 25 32 40 50 63 20 mm (3/4) 25 mm (1) 32 mm (1-1/4) 40 mm (1-1/2) 50 mm (2) 63 mm (2-1/2) Cylinder stroke (inch) How to Order Without auto switch 40 L 25 N CG1 L N 25 M9NW 40 CDG1 With auto switch Number of auto switches Built-in magnet Mounting style Nil S n 2 pcs. 1 pc. n pcs.

10 12 33.5 22.5 12 46 44 23.5 55 50,100,150,200,250,300,350,400,450,500,550,600 Model KC KA KB KH KW LA LL LW LZ ML MM N PA PB PC Q QA QB L QW CY1F10 6.5 44 8 19 59 58 20 86 19 5 M3 x 0.5 18.5 40 40 8.5 90 4 12 38 33 CY1F15 6.5 51 10 19 66 65 20 99 19 5 M3 x 0.5 18.5 50 50 7 97 4 12 53 40 CY1F25 7.5 66 13 27 84.5 89 25.5 128.5 17 9 M5 x 0.8 24 65 65 8 129 5.5 14.5 70 52 P (Piping port) Model

10 12 33.5 22.5 12 46 44 23.5 55 50,100,150,200,250,300,350,400,450,500,550,600 Model KC KA KB KH KW LA LL LW LZ ML MM N PA PB PC Q QA QB L QW CY1F10 6.5 44 8 19 59 58 20 86 19 5 M3 x 0.5 18.5 40 40 8.5 90 4 12 38 33 CY1F15 6.5 51 10 19 66 65 20 99 19 5 M3 x 0.5 18.5 50 50 7 97 4 12 53 40 CY1F25 7.5 66 13 27 84.5 89 25.5 128.5 17 9 M5 x 0.8 24 65 65 8 129 5.5 14.5 70 52 P (Piping port) Model

(See page 22 to 23, Table 5,6.) < Applicable Auto switches > Solid state auto switch D-M9N(V)M9P(V)M9B(V) D-M9NW(V)M9PW(V)M9BW(V) D-M9NA(V)M9PA(V)M9BA(V) Reed auto switch D-A90(V)A93(V)A96(V) Figure 4.

30 75.5 76 62 34 35 30 85.5 86 72 40 45 40 90.5 91 77 40 50 45 8-3-8 9 Compact Slide Series MXU Construction MXU6 (6) MXU10 (10) MX MTS MY CY MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com CX MXU16 (16) D-X With auto switch 20Data Component Parts Description

Air Cylinder: Standard Type Double Acting, Single Rod How to Order MB Series 32, 40, 50, 63, 80, 100, 125 RoHS 50 B 32 Z MB With auto switch MDB M9BW Z B 32 50 With auto switch (Built-in magnet) Number of auto switches Mounting type Bore size Accessories 1 Auto switch Nil No bracket N Pivot bracket 32 32 mm 40 40 mm 50 50 mm 63 63 mm 80 80 mm 100 100 mm 125 125 mm Nil Without auto switch

20 65.5 66 52 24 24 20 75.5 76 62 34 35 30 75.5 76 62 34 35 30 85.5 86 72 40 45 40 90.5 91 77 40 50 45 8-3-8 9 Compact Slide Series MXU Construction MXU6 (6) MXU10 (10) MX MTS MY CY MG CX MXU16 (16) D-X With auto switch 20Data Component Parts No. q Note Hard anodized No. !

S 1 pc. n n pcs. 40 40 mm 50 50 mm 63 63 mm 80 80 mm 100 100 mm * Not available with auto switch. With rod boot/cushion Built-in Magnet Cylinder Model Rod boot Nil Without rod boot J Nylon tarpaulin K Heat resistant tarpaulin If a built-in magnet cylinder without an auto switch is required, there is no need to enter the symbol for the auto switch.