SMC Corporation of America
Elite Part Number Search
Search Results "RDLQL50-30-BR"

<br>It is recommended that flow switches for water be installed so that the fluid flows from the bottom to the top when piping vertically. <br>Also, in order to perform normal flow rate detection, install the product so that the flow rate detector is always full. <br>For further instructions, refer to the operation manual, which can be found https://www.smcpneumatics.com/Part-Builder-Links_ep_2458-1.html?https://smccatalog.partbuilder.smcpneumatics.com/support/faq/en-jp/?ca_id=flow-switches&fa_id=10503

<br>Accumulated pulse output mode: This mode is used when the flow rate is monitored remotely, and a 50 ms pulse output is output every time a certain amount of fluid flows. The accumulated flow can be measured by counting the number of pulse outputs.<br><br>

<br>Type the series name (e.g., VX2) of the 2-way valve in the search field, and then click on the search icon. <br>Next, click “Detail,” and then download the discontinued series’ catalog. If the old part number is not listed, please contact SMC. <br>Information on discontinued products can be found here.

<br>For detailed information including replacement part numbers, refer to the “Replacement Parts” section at the bottom of the “Construction” page in the catalog. <br>Select a diaphragm assembly that matches the model type of the valve body. <br>The VXF(A)2 series catalog can be found here.

Terminal No. 1: + (plus) <br>Terminal No. 2: - (minus)<br>Note 1) There is no polarity for some types of valves. <br>Note 2) For SGC and SGH series valves, refer to the “Specific Product Precautions” section in the respective catalogs.

<br>For example, the LVM10R1 (N.O. type) uses IN as “1” and OUT as “2” for convenience, while the JIS symbol (as shown in the catalog) is a double-sided arrow. Note, however, that the flow direction of the LVM11/13 direct operated poppet type is fixed as indicated by the JIS symbol (as shown in the catalog).<br><br>

<br>However, while the insertion tool body is the same, the insert pins in the parts case are different for inch and metric sizes and need to be selected accordingly. <br>The insert pins can be ordered separately as replacement parts. <br>Refer to the operation manual, which can be found here.

<br>For further details of the communication function, refer to the thermo-chiller communication function manual. <br>On the SMC website, go to the “Operation Manuals” section, and then click on “Temperature Control Equipment.” From there, select the desired thermo-chiller communication function manual.

<br>If the product is not to be used for a long period of time (1 month or more), perform operation without a load regularly or drain the circulating fluid before storage. <br>For details, refer to section “8.4 Stop for a Long Time” in the HRS series operation manual, which can be found here.

<br>It can also be determined by looking at the filter part number. For example, the element type used with an “FGDCA-03-B002N-B” is the “EB100-002N.” For details, refer to the respective catalogs.<br><br>

<br>They were replaced with the CH2E/CH2F/CH2G/CH2H series. <br>The external dimensions, cylinder mounting dimensions, and workpiece mounting position dimensions are the same as those of the old series, and the nominal pressure specifications are the same as well. <br>The CH2E/CH2F/CH2G/CH2H series catalogs can be found https://www.smcpneumatics.com/Part-Builder-Links_ep_2458-1.html?https://smccatalog.partbuilder.smcpneumatics.com/support/faq/en-jp/?ca_id=hydraulic-cylinders&fa_id=10607