SMC Corporation of America
Elite Part Number Search
Search Results "MS-5HLH-6"

By comparing this average pressure value with the set pressure value, switch output (ON//OFF) is determined. t (ms) t (ms) Time Switch output operation when normal ON OFF Time Switch output operation when anti-chattering function is used.

Time t (ms) t (ms) (Averaging) (Averaging) Switch output ON operation [Selectable response times: t] 2.5ms (normal), 24ms, 192ms or 768ms The normal setting is selected when shipped from the factory.

Time t (ms) t (ms) (Averaging) (Averaging) Switch output operation when normal ON [Selectable response times: t] 2.5ms (normal), 24ms, 192ms or 768ms The normal setting is selected when shipped from the factory.

Standard Specifications Standard type (2 W) Items Type Large flow type (3.2 W / Energy saving type) Valve construction Fluid Maximum operating pressure 4 port direct operated poppet valve Air/Inert gas 0.7 MPa 0 MPa/101.2 kPa ON: 4 ms 1, OFF: 2 ms 1 10 to 50C Note 2) Valve specifications Electrical specification Minimum operating pressure / Vacuum Response time Note 1) L plug connector Base

By comparing this average pressure value with the set pressure value, switch output (ON//OFF) is determined. t (ms) t (ms) Time Switch output operation when normal ON OFF Time Switch output operation when anti-chattering function is used.

Response time selections: 20 ms, 160 ms, 640 ms, 1000 ms, 2000 ms Cut-to-zero display function With the ISE75 series, users can enable or disable a function (cut-to-zero display function) that displays pressure values of 0.3 MPa or less as zero (0.4 MPa or less in the ISE75H series).

Description 1 DC(-) (for sensor) 2 DC(+) (for sensor) 3 Sensor input 4 N.C. 5 DC(-) (supply voltage) 6 DC(+) (supply voltage) 7 OUT1 8 OUT2 -16No.PF-OMG0008-F Internal circuit and wiring example Use sensor PF25 series for accurate measurement.

(mm) Metric size M TD0604 6 4 TD0806 8 6 Translucent (material color) Air, Water, Inert gas TD1075 10 7.5 TD1209 12 9 4 2.5 H 10 m 20 m Roll KK Color Fluid Note 1) D Flexibility: Improved by approx. 20% * SMC comparison (Fluoropolymer tubing, Series TL/TIL) Insert fitting Miniature fittings M, MS series (Hose nipple type) Fluoropolymer fitting LQ1 series MS Applicable fittings Note

The load does not work. -15No.D-#S-OML0002-B Specification Specifications Auto switch model D-P3DW Wiring 2-wire Output Applicable load 24 VDC Relay / PLC Load voltage 24 VDC (20 to 28 VDC) Load current 6 to 40 mA Internal voltage drop 5 V or less Current leakage 1 mA or less Operating time 40 ms or less Indication light Operating range: The red LED lights up.

Tighten with the cross recessed round head screw. (6) Mount the tube gasket 11 to the left cover 2 to mount to the body 1 .

Fittings & Tubing Air Cylinders Rotary Actuators Nil 1 Note 6) Set pressure c 0.05 to 0.85 MPa setting 0.02 to 0.2 MPa setting + Polycarbonate bowl Metal bowl Nylon bowl Metal bowl with level gauge With bowl guard Nylon bowl with bowl guard + Nil 2 6 8 C 6C Bowl d Semi-standard J Drain port Note 7) Drain guide 1/8 Drain guide 1/4 + Nil N Exhaust mechanism e Relieving type Non-relieving type

/O.D. mm Symbol 01 02 03 04 N01 N02 N03 N04 Symbol 07 09 11 13 Applicable tube O.D. mm 6 8 10 12 1/4" 5/16" 3/8" 1/2" Symbol 50 60 65 80 85 110 5/8 6/9 6.5/10 8/12 8.5/12.5 11/16 Metric size The figures in ( ) indicate the internal diameter of the applicable hose. Inch size 1

Connection Type: Screw⇔Tube Connection, Connection screw: M, Thread-to-Tube Connection Shape: [Elbow (Barb)] Barb Elbow (H), Material: [Resin] 00010, Applicable tube material (O.D./I.D.): Polyurethane (4/2.5), Gasket Material: Nylon 66・GF30%, Made to Order Specifications: N/A

Conductor size (mm2) Normally: Red ON: Green OFF: Red ON: Red OFF: Green [Default setting] Normally: Green Output OUT1 LED (Green) 1 ms [Default setting] 20 ms 160 ms 640 ms 1280 ms Red ZS-28-C 0.8 to 1.0 Output OUT2 LED (Red) 24-26 0.14-0.2 Yellow ZS-28-C-1 1.0 to 1.2 3rd digit button (UP) Thank you for purchasing an SMC PSE300 Series Pressure Sensor Controller.

Output mode Hysteresis mode 21.5 18 Reversed output Normal output : Arbitrary display PNP output NPN output Pressure setting 0.500 MPa 6.6 10 OUT1 set value OUT2 set value Bottom value Peak value OUT1 hysteresis OUT2 hysteresis Hysteresis 0.050 MPa Delay time 1.0 ms or less Return to function selection mode. Press the button to set.

PF2D30 series 8 OUT2 Time 5 6 7 8 PF2D520 PF2D540 PF2D504 Input of the Set point 1 (OUT1) Measurement of the Set value (OUT1) Input of the Set value for the lower 3 digits (OUT1) Safety Instructions Non-Reverse output Mounting and Installation Outline of setting ON 50 ms Warning Display mode OFF No Set value input 4 Set value or 3 4 Set value or 3 Accumulated pulse output mode Installation

PLC D-A76H D-E76A lC Citcuil D-A73C PLC D-A80C PLC 1.2 ms Solid State l\rodd Nurnbef D-F79 lC Circuit, Reay, PLC D-F7P D-J79 D-F/NV lC Circuit, Relay.

Set value P_1 Hysteresis H_1 Pressure Piping Tightening the connection thread For connecting to the body (piping specification: -M5) After hand tightening, apply a spanner of the correct size to the spanner flats of the piping body, and tighten with a 1/6 to 1/4 rotation. As a reference, the tightening torque is 1 to 1.5 Nm.

Set value P_1 Hysteresis H_1 Pressure Piping Tightening the connection thread For connecting to the body (piping specification: -M5) After hand tightening, apply a spanner of the correct size to the spanner flats of the piping body, and tighten with a 1/6 to 1/4 rotation. As a reference, the tightening torque is 1 to 1.5 Nm.