SMC Corporation of America
Elite Part Number Search
Search Results "LEFG40-S-600"

(Variable) 3% F .S. or less (Fixed) 1 to 10% of set prss. (Variable) 1 to 10% of set press. (Adjustable) Hysteresis Data ON: when output is ON (Red) ON: when output is ON (Red) ON: when output is ON (OUT1: Red, OUT2: Green) Indicator light Trimmer adjustment 3 turns 200 degrees 3 turns 200 degrees 3 turns 200 degrees None 1 to 5 V 5% F .S.

Dimensions/40 to 100 Basic/CA2YB 4-J 2-P (Rc, NPT, G) MM Width across flats KA G G D E H1 AL B1 K A N F N B C M S + Stroke H ZZ + Stroke (mm) Bore size (mm) 40 50 63 80 100 Stroke range Up to 500 Up to 600 Up to 600 Up to 700 Up to 700 B C A AL B1 D E F G H H1 J K KA M MM N P S ZZ 30 35 35 40 40 27 32 32 37 37 60 70 85 102 116 22 27 27 32 41 44 52 64 78 92 16 20 20 25 30 32 40 40 52 52 10

PFA703H--28 PFA703H--68 PFA706H--28 PFA706H--68 PFA703H--29 PFA703H--69 PFA706H--29 PFA706H--69 3000 3000 150 150 6000 6000 300 300 PFA712H--28 PFA712H--68 PFA712H--29 PFA712H--69 12000 12000 600 600 19

For details, refer to the optional accessory (page 11). 6 HEF Series Cooling Capacity Circulating fluid: Water, Flow rate: 1 L/min Circulating fluid: Water, Flow rate: 1 L/min, When constant fan speed mode is selected 600 600 500 500 Cooling capacity [W] Cooling capacity [W] Ambient temperature 25C 400 400 Ambient temperature 25C 300 300 200 200 Ambient temperature 35C Ambient temperature

(Only for HRZ010-W*S) 0, 15 to 40 LPM 0, 4 to 10.6 GPM 6 LOW FLOW 0, 8 to 40 LPM 0, 2.1 to 10.6 GPM (Only for HRZ010-W*S) 7 FLOW UNIT LPM, GPM Allows the selection of the unit of flow rate. 8 PRESS UNIT MPa, PSI Allows the selection of the unit of pressure. 9 SLAVE ADRS. 1 to 16CH Allows the selection of the slave address for serial RS-485 communication.

Response time 7 s 2 Ambient temperature characteristics 5% F.S. 1: The rated temperature range is of a single temperature sensor.

V(m/s) Example: Load limit at rod end when air cylinder 50 is actuated with max. actuating speed 325mm/s.

[Space required for maintenance] Front: 600 mm Back: 600 mm Top: 600 mm Right side: 600 mm Left side: 600 mm Caution 1. Provide ventilation space. Unless a necessary ventilation space for each piece of equipment is provided, this product could cool poorly or stall.

390(7s 4,AC250V G ()JIS B0202(ISO228-1) ISO1179-1(G )ISO16030(G )JIS B0202(ISO228-1) ISO11791(G ) () ISO1179-1 ISO1179-2 ISO1179-3 ISO1179-4 () ISO16030(G )()ISO16030 () 0100 1 3F.S. 7 s 2 5F.S. 1090 2 -29No.PF-OMN0009CN-F (PVC ) PF3W511 PF3W521 (3 mPas(3 cP)) 1 10100 L/min 30250 L/min 070 () 3F.S. 2F.S. 5%F.S.(25 ) 2 2 3 1 s 15 V 1 k 420 mA DC12 V 300 DC24 V 600 ()

Response time (With anti-chattering function) Output short circuit protection Display 2% F .S. 1 digit or less (at ambient temperature of 25 3C) Green LED (OUT1: Lights when ON), Red LED (OUT2: Lights when ON) Output voltage: 1 to 5 V 5% F.S. or less (in rated pressure range) Linearity: 1% F .S. or less Output impedance: Approx. 1 k No-voltage input (Reed or solid state), input 5 ms or more

24 V: 600 Min. load impedance 50 -S/-R (Auto-shift input mode) With auto-shift switch output NPN open collector output type-2 output Max. 28 V, 80 mA Residual voltage 1 V or less -X (Copy function switch output) -S/-R (Copy input mode) NPN open collector output type-2 output Max. 28 V, 80 mA Residual voltage 1 V or less -22No.PS-OMU0009-D -V/-T (Analog output mode) Switch output PNP open

stroke Note) 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 2000 2000 2000 2000 2000 2000 2000 32 40 50 63 80 100 125 Minimum Stroke for Auto Switch Mounting 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800

, 600 80 1900 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 100 1900 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 2000 125 Intermediate strokes are available.

80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 Symbol Specifications 100 1500 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 Heat resistant cylinder (150C) -XB6 Intermediate strokes are available.

or less (24 VDC) P2: Analog output 1 to 5 V Allowable load resistance 100 k or more P6: Analog output 4 to 20 mA Allowable load resistance 300 or less (12 VDC), 600 or less (24 VDC) 339 LLB Series Refer to the operation manual for how to set and to operate.

, 700, 800 1300 12-CY3R40 40 Rc1/4 NPT1/4 G1/4 12-CY3R50 12-CY3R63 50 63 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 Note 1) Stroke exceeding the standard stroke but below the maximum manufacturable stroke is available as special order.

Crean class Amount of Type Speed recommended vacuum (mm/s) ISO 14644-1 Fed.Std.209D aspiration 6 1000 10 5 100 20 4 10 30 6 1000 50 5 100 60 4 10 70 6 1000 20 5 100 30 4 10 50 6 1000 30 5 100 70 4 10 90 600 11-LEJS40 1200 600 *Please aspirate it from the port on both sides when aspirating 50/min(ANR). Please select "D" about the type. 11-LEJS63 1200 * Based on SMC test condition.

Response time (including sensor response time) 200 ms (No filter) 1.5 s (with filter) or less Indicator accuracy 0.5%F.S. 1 digit Display method 3 1/2 digits 7 segment display, two color (red/green) indication, sampling cycle: 5 times /1 s Indicator lamp OUT1: Turns on when ON (green), OUT2: Turns on when ON (red) Enclosure IP40 Environment Operating temp. range Operation: 0 to 50 oC, Storage

1 k S: Analogue output 4 to 20 mA Max. load impedance Power supply voltage 12 V: 300 Power supply voltage 24 V: 600 Min. load impedance 50 -S/-R (Auto-shift input mode) With auto-shift switch output NPN open collector output type 2 output Max. 28 V, 80 mA Residual voltage 1 V or less -17No.PS-OMM0003-J -V/-T (Analogue output mode) Switch output PNP open collector output type 2 output Max