Contents Action 12 12 CQSB12-S-PS CQSB12-T-PS Kits include items !2, !3 and !4 from the table above. 16 16 CQSB16-S-PS CQSB16-T-PS Kits include item !3 Single acting Spring return Single acting Spring extend 20 20 CQSB20-S-PS CQSB20-T-PS from the table above. 25 25 CQSB25-S-PS CQSB25-T-PS Seal kits consist of item !
Impact acceleration [m/s2] 5 0 50 100 150 200 250 300 Speed [mm/s] Relationship between speed and impact acceleration 8-18-2 in vacuum environments (1.3 x 104 Pa) Carefully designed for low particulate generation, low leakage, and low outgassing.
u s d Particulate generation has been reduced at the stroke ends by reducing impact using a sine cushion and by stopping the stroke using an internal stopper. i e Reduction of outgassing due to surface treatment n Impact acceleration [m/s2] o u d t R g g e a c 1 s u s d 5 i e n R g All the external parts (made of aluminum alloy) such as the body and slide table are electroless nickel plated
Standard motor LJ1H202NF-K 100W to 250 [Tamagawa Seiki Co., Ltd.]
Gap too small Green 2 a Place the gap gauge on the detection nozzle for precise adjustment. s Confirm applied air pressure.
Valve model Type of actuation Port size 1 4/2 (P A/B) Flow characteristics Note 2) Note 3) Effective area mm2 4/2 5/3 (A/B EA/EB) Weight (g) Pilot port size Cv C [dm3/ (s bar)] b Cv C [dm3/ (s bar)] b Grommet Single Double Closed center Exhaust center Pressure center Single Double Closed center Exhaust center Pressure center Single Double Closed center Exhaust center Pressure center 48
Mass (g) D-B30 D-B30J D-B31 D-B31J D-B35 D-B35J Auto switch model 190 250 190 250 190 250 0.5 Lead wire length (m) Auto Switch Internal Circuit 3 368 368 368 D-B30 5 462 462 462 Contacts protection resistance Brown (Terminal 1) Blue (Terminal 2) Contacts (Magnetism detection) Lead wire length In case of the grommet type (J type), the lead wire length is 0.5 m.
Standard motor LJ1H202NF-K 100W to 250 [Tamagawa Seiki Co., Ltd.]
250 250 Lead wire length D-B31 3 m (L) 268 268 268 5 m (Z) 462 462 462 Contacts protection resistance () () Reed switch Neon bulb Current limiting resistance Lead wire length In case of the grommet type (J type), the lead wire length is 0.5 m.
How to Order ITV 209 0 0 1 2 5 S Pressure display units Pressure range 5 kPa 9 1.3 to 80kPa Power supply voltage Cable connector type S L Straight type 3m Right angle type 3m Without cable connector 0 1 24V DC 12 to15V DC N Option Input signal Bracket 0 1 2 3 4 Current type 4 to 20 mA DC Without bracket Flat bracket L-bracket B Current type 0 to 20 mA DC Monitor output Thread type Port
DXT170-176-2-01 DXT170-176-2-02 DXT170-176-2-03 DXT170-176-2-04 DXT170-176-2-07 DXT170-176-3-51 DXT170-176-3-06 DXT170-176-3-05 DXT170-176-3-53 For Series VZ300/500 With light/surge voltage suppressor With surge voltage suppressor 100 VAC 200 VAC 110 VAC 220 VAC 240 VAC 6 VDC 12 VDC 24 VDC 48 VDC S E For VZ120 Indicator light is not available for grommet type.
Flow Speed 3/4B (21.6) 1B (27.6) 11/4B (35.7) 11/2B (41.6) 2B (52.9) 21/2B (67.9) 2 1.8 3B (80.7) 1.6 1.4 Flow speed (m/s) 1.2 1 4B (105.3) 0.8 5B (130.8) 0.6 6B (155.2) 0.4 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 0.2 50 100 150 200 250 300 350 400 0 Flow
, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 25 3000 32 3000 40 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 50 5000 63 Note 1) Long stroke type (XB11) applies to the strokes exceeding 2000 mm.
VMG1-06-150-300 VMG1-06-200-300 VMG1-06-150-600 VMG1-06-200-600 VMG1-06-150-100 VMG1-06-200-100 VMG1-06-150-150 VMG1-06-200-150 VMG1-08-250-100 VMG1-08-300-100 VMG1-08-350-100 VMG1-08-250-150 VMG1-08-300-150 VMG1-08-350-150 VMG1-08-250-300 VMG1-08-300-300 VMG1-08-350-300 VMG1-08-250-600 VMG1-08-300-600 VMG1-08-350-600 Nozzle size Nozzle length 1.5 2 1.5 2 1.5 2 1.5 2 2.5 3 3.5 2.5 3 3.5 2.5
VMG1-06-150-300 VMG1-06-200-300 VMG1-06-150-600 VMG1-06-200-600 VMG1-06-150-100 VMG1-06-200-100 VMG1-06-150-150 VMG1-06-200-150 VMG1-08-250-100 VMG1-08-300-100 VMG1-08-350-100 VMG1-08-250-150 VMG1-08-300-150 VMG1-08-350-150 VMG1-08-250-300 VMG1-08-300-300 VMG1-08-350-300 VMG1-08-250-600 VMG1-08-300-600 VMG1-08-350-600 Nozzle size Nozzle length 1.5 2 1.5 2 1.5 2 1.5 2 2.5 3 3.5 2.5 3 3.5 2.5
Time to reach vacuum (S)
Nil S n M L Auto switch type Bore size Nil Without auto switch (built-in magnet cylinder) 40mm 50mm 63mm 40 50 63 Refer to the table below for auto switch models. Locking direction Cylinder stroke (mm) Refer to the standard stroke table on page 3.
Made to Order (Refer to page 1882 for details.) 32 1500 up to 1000 250 40 1500 up to 1000 250 Symbol Specification Made of stainless steel XC6 50 1500 up to 1200 250 63 1500 up to 1200 250 80 1500 up to 1400 250 100 1500 up to 1500 250 Note 1) Strokes shorter than the recommended minimum stroke (1 to 249 st) can be manufactured, but cushion capability may not be satisfied since the effective