Clean series 10 AF 03 A 30 F J B 21 AF 03 A 30 F J B Copper, fluorine and silicone-free + Low particle generation q w e r t Air filter Option/Semi-standard:Selectoneeachfora to e. Option/Semi-standardsymbol:Whenmorethanonespecificationisrequired,indicateinalphanumericorder.
Regulator Series AR-B 1021Series ARK-B 1021Regulator with Backflow Function How to Order Clean series K F 10 AR B 30 03 BG 1N K F 21 AR B 30 03 BG 1N Copper, fluorine and silicone-free + Low particle generation q r t y w e Regulator Option/Semi-standard: Select one each for a to g.
Pressure gauge Pressure gauge Port size Applicable series Symbol Port size VBA10A-02 02 03 04 VBA1A VBA2A VBA4A 1/4 3/8 1/2 VBA11A-02 Elbow silencer Silencer Combination of Thread Type and Options VBA20A-03 Body size Option Semi-standard Thread type Nil S GN N GS G Nil GLS -Z LN LS GLN Nil F N T Nil F N T Nil F N T 10A 11A VBA22A-03 20A 22A 40A 42A 43A VBA40A-04 Air Tank Compatibility Chart
IS*-OMX0095-B PRODUCT NAME Pressure Switch Pressure Switch with T-Spacer Pressure Switch with L-Piping Adapter Pressure Switch with Piping Adapter MODEL / Series / Product Number IS10M-(20,30,40,50,60)(-1,6,L,P,Z)-D IS10T-(20,30,40,50,60)-(F,N)(-6,L,P,Z)-D IS10L-(20,30,40,50,60)-(F,N)(-6,L,P,R,Z)-D IS10E-(20,30,40,50,60)-(F,N)(-6,L,P,R,Z)-D Contents Page 1. Safety Instructions 2-7 2.
PF3W 5 04 03 1T Remote sensor unit Integrated display PF3W 7 04 03 AT M Type Made to Order 5 7 Remote sensor unit Integrated display Thread type X109 X128 X143 Seal material EPDM Nil N F Rc NPT G Analog 4 to 20 mA 2 output type Note) Rated flow range (Flow range) Piping material brass Symbol Rated flow range Note) Applicable only for remote type with 04 20 40 11 21 0.5 to 4 L/min 2 to 16
Large effective area Low power consumption 1/4 67 111 31 55 40 64 (Max. 73) AVL2000-*02 Manual/Manual solenoid lock out Modular design 1/4 67 20.5 111 31 55 34 40 64 (Max. 73) AVL2000-*02-*DZM 3/8 76 118 36 57 48 64 (Max. 73) AVL3000-*03 How to Order 3/8 76 12.5 118 36 57 34 48 64 (Max. 73) AVL3000-*03-*DZM 1/2 98 133 47 61 52 64 (Max. 73) AVL4000-*04 G 20 00 F DZM R 5 02 AVL 1/2 98
(Refer to Copy function on page 8.) 3 Series ZSE10(F)/ISE10 Dimensions ZSE10(F)/ISE10 M5 6.4 (7.7) (30) 2 x 3.3 M5 x 0.8 (12) 1.2 25 13 3.5 9.8 51.8 4.2 ZSE10(F)/ISE10 M5R 1.2 6.4 25 51.8 4.2 9.8 4.5 M5 x 0.8 4 Digital Pressure Switch Series ZSE10(F)/ISE10 ZSE10(F)/ISE10 01 6.4 2 x 3.3 1.2 Width across flats 10 Width across flats 12 11 13 13 25 3.5 8 R1/8 9.8 12.5 51.8 4.2 ZSE10(F)/ISE10
F = mg Mass m Movement I: Inertial moment Refer to page 100. Static torque calculation Tf = F x L (Nm) Load . g = 9.8m/s2 F: Pressing force (N) : Angular acceleration Load .
M1 = F x L Port side A M2 = F x L M3 = F x L Note) Deflection: Displacement of section A when force acts on section F REAH10 REAH10 REAH10 Slider Type/Slide Bearing REAS Slider Type/Ball Bushing REAL 0.08 0.03 Deflection (mm) Deflection (mm) Deflection (mm) 0.02 0.06 0.02 0.04 0.01 0.01 0.02 0.5 1.5 2.5 0 0.5 1.5 0 0.5 1.0 1.5 0 1.0 2.0 Moment (Nm) 1.0 Moment (Nm) Moment (Nm) REAH15, 20,
Uses crimp tool 1'1-01-0014 and pin dxtraction tool numbe|I l -03-0M4. trtrtrtr MEEre tslt6ll=7tr -@mmtr fol r|s (POWER Connector) (Electric Actuators) ORIGIN SWITCH (+) 4 i t-= i l f (our) 5 t) 6 I I r r LllVlT SWITCH (+) 7 f (our) B r l : l (1 I A PHASE (Orange) 24V 1 +, DC24V OV lniucr ||nillor $crlss U( hmcwtmdr Series LCOC Connecting Example . lnterface Connector Omron part number XG4M
(2/4) Alarm operations Alarm threshold and others A.RUN P.RUN A.STP Code Alarm name OFF Display Default setting Settable range Display Set temperature 1.0oC (33.8 o F) (-)5 1.034.0 oC (33.893.2 o F) Monitoring method Circulating fluid drop 0 03 AL04 discharge temp.
Tel :03-3502-2740 Fax:03-5251-7240 August 1996, 14(RP)
l h 10.2 10.2 l + Stroke f * For one side rod boot type, a rod boot is mounted on the lock side (left side of the drawing above).
A displayed value can be adjusted within 7% F .S. of the pressure when ex-factory. (3.5% F .S. for ZSE30AF (compound pressure)) Adjustable range of display calibration function Note) When the precision indicator setting function is used, the set pressure value may change 1 digit. 10 Series ZSE30A(F)/ISE30A 2-Color Display High-Precision Digital Pressure Switch Fl in brackets stand for the
PNP sensor input NPN sensor input Without input block Nil M12, 2 inputs A D M12, 4 inputs B E M8, 4 inputs C F * When not selecting an SI unit, the symbol will be nil. u P, E port entry, SUP/EXH block assembly P, E port entry Internal pilot Internal pilot, Built-in silencer U side (2 to 10 stations) U C D side (2 to 10 stations) D E Both sides (2 to 24 stations) B F * The 3/5(E) port is
Uses crimp tool 1'1-01-0014 and pin dxtraction tool numbe|I l -03-0M4. trtrtrtr MEEre tslt6ll=7tr -@mmtr fol r|s (POWER Connector) (Electric Actuators) ORIGIN SWITCH (+) 4 i t-= i l f (our) 5 t) 6 I I r r LllVlT SWITCH (+) 7 f (our) B r l : l (1 I A PHASE (Orange) 24V 1 +, DC24V OV lniucr ||nillor $crlss U( hmcwtmdr Series LCOC Connecting Example . lnterface Connector Omron part number XG4M
M1 = F x L F A F F A L L L Opposite port side Guide central axis (single axis type) Port side For the dual axis type, this is the cylinder's central axis.
22 Accessories (Options) Base Integrated with Transformer Dryer Transformer E F D C A Part No.
Pilot valve assembly SF4-w F-30 SF4-w F-30 SF4-w F-30 SF4-w F-30 SF4-w F-30 SF4-w F-30 SF4-w F-30 SF4-w F-30 SF4-w F-30 6. Return spring B 7. Detent assembly SF4-mF-30 SF4-mF-30 8.
Bellows seal C Double acting Bellows seal F Single acting (N.C.)