K 5.5 L 72 M 37 N 2 O 30 P Rc1/4 Q R 59 Sa Sb T 500 U 250 V 310 Model ZH30--X185 ZH40--X185 28.5 146.5 M4 x 0.7 10 203 90 64 25 27.2 33.5 196.8 74.5 6 90 78 6.5 92 47 2.3 42 Rc3/8 76 500 250 310 Note 1) This thread portion is intended to adjust the product characteristics.
S n Auto switch Without auto switch (Built-in magnet) Nil Bore size (Stroke (mm)) For the applicable auto switch model, refer to the table below. 8 12 16 20 25 25, 50, 75, 100, 125, 150 50, 75, 100, 125, 150 75, 100, 125, 150, 175, 200 100, 125, 150, 175, 200, 225, 250 100, 125, 150, 175, 200, 225, 250, 275, 300 Option Nil Standard (with urethane bumper) With shock absorbers 2 pcs.
Check the power supply voltage for output is above 20 V.
TB W Counter bore depth TC Inner cover holding screw Note) (mm) E 4 6 J M6 x 1 M10 x 1.5 LD 5.6 9.2 L 67 90 K 21 20 JK 10 12 HP 44 73.5 HL 37.6 63.3 HI 23 39 HA 23 39 H 45 75 G 10 9 F 12.5 25 EK 4 6 ED 9.5 13 C 6.4 10.2 B 10.5 16 A 8 12 Model CYV15 CYV32 +0.030 H9 0 +0.030 H9 0 Z 132 165 Y 2.5 3.5 W 69 115 TC 0.5 0.5 TB 15 22 TA 20 22.5 T 30 34 R 45 79.5 QW 48 83 Q 112 147 PC 10 12 PB 60
Annual cost reduction effect [Calculation conditions] Electric power cost: 1.55 yen/m3 [Work model] Working hours: 6000 h (250 days/year) Supply pressure: 1.0 MPa Set pressure: 0.2 MPa Comparison between IR3000-A and the current IR3000 Comparison between IR1000-A/IR2000-A and the current IR1000/IR2000 300 300 Annual cost of power consumed by compressor [1000 yen/year] 250 250 When 20 units
Flow Characteristics at the Number of Manifold Stations (Operated single/double type individually) Passage/Stations Station 1 Station 5 Station 10 Station 15 Station 20 2.7 0.15 0.62 2.8 0.10 0.65 C [dm3/(sbar)] b Cv 2.7 0.16 0.61 2.8 0.12 0.66 2.7 0.16 0.61 2.9 0.12 0.66 2.7 0.15 0.61 2.9 0.12 0.66 2.6 0.20 0.63 2.9 0.12 0.66 1 4/2 (P A/B) C [dm3/(sbar)] b Cv 4/2 5/3 (A/B R1/R2) Manifold
Deflection + L F F (Dimension when extended) + M Built-in coil scraper and Lube-retainer MAllowable lateral load graph MSelectable proximity switches CKZP57L TURCK P&F 400 Allowable lateral load [N] 350 300 250 200 MAdjustable connector angle 150 100 CKZP57L: 45, 90 CKZP71: 0, 45, 90 50 0 0 50 100 150 200 250 Offset distance L [mm] CKZP71 0 50 100 150 200 250 300 350 400 450 500
Standard Strokes Bore size [mm] Standard stroke [mm] Max. manufacturable stroke 32 25, 50, 75, 100, 125, 150, 175, 200, 250, 300 300 40 25, 50, 75, 100, 125, 150, 175, 200, 250, 300 300 45 25, 50, 75, 100, 125, 150, 175, 200, 250, 300 300 50 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400 400 56 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400 400 63 25, 50, 75, 100, 125, 150
20 20 0.15MPa 0.15MPa 0.15MPa 10 10 10 0.2MPa 0.2MPa 0.2MPa 100 200 300 0 100 200 300 0 100 200 300 0 Detection distance (m) Detection distance (m) Detection distance (m) Example 1) When requiring 300m detection, select the detection nozzle of 1.0 with supply pressure 0.2MPa.
Analog output Output impedance Approx. 1 k Output current (Rated pressure range) Current output: 4 to 20 mA2.5%F.S. Current output 4 Linearity 1.5%F.S. 1.0%F.S.
AMG 650 s5o) AMG 250 N I Body Size.
ISA2-G ISA2-H Detection side piping: 6 x 4 tubing 5 m Detection nozzle: 1.5 Standard pressure: 100 kPa Standard pressure: 100 kPa Detection side piping: 6 x 4 tubing 5 m Detection nozzle: 2.0 0.4 0.6 Standard pressure Standard pressure 0.5 mm 0.25 mm Detection distance (mm) Detection distance (mm) 0.5 0.3 0.4 0.2 0.3 0.15 mm 0.15 mm 0.2 0.1 0.1 0.03 mm 0.01 mm 0 0 50 0 250 200 150 100 250
M8 x 1.25 G 1/8 M22 x 1.5 126 13 15 8 15 24 32 6 62 44 17 20 24 28 8 8 22 8.2 11 20 25 G 1/8 M22 x 1.5 M10 x 1.25 137 17 15 10 15 30 32 8 65 50 20 22 28 33.5 8 8 22 11 10.2 22 With Rod Boot (mm) Item h KK 1 to 50 AM C e f K Stroke 51 to 100 101 to 150 151 to 200 201 to 300 301 to 400 401 to 500 Bore 20 M8 x 1.25 71 20 8 36 20 6 84 96 109 134 159 25 M10 x 1.25 74 22 10 36 20 8 87 99 112
M8 x 1.25 G 1/8 M22 x 1.5 126 13 15 8 15 24 32 6 62 44 17 20 24 28 8 8 22 8.2 11 20 25 G 1/8 M22 x 1.5 M10 x 1.25 137 17 15 10 15 30 32 8 65 50 20 22 28 33.5 8 8 22 11 10.2 22 With Rod Boot (mm) Item h AM C e f K KK 1 to 50 Stroke 51 to 100 101 to 150 151 to 200 201 to 300 301 to 400 401 to 500 Bore 20 20 8 36 20 6 M8 x 1.25 71 84 96 109 134 159 25 22 10 36 20 8 M10 x 1.25 74 87 99 112
MXQ16-20 MXQ16-20 MXQ16-20 MXQ16-20 D0.02 0.04 MXQ16-10 MXQ16-10 MXQ16-10 0.01 MXQ16-10 MXQ16-10 -X 0 0 400 100 200 300 150 150 50 100 200 50 100 200 0 20Load (N) Load (N) Load (N) Data 20 20 20 Lr = 160 mm 0.08 MXQ20-125 MXQ20-150 MXQ20-125 MXQ20-125 MXQ20-10 MXQ20-10 MXQ20-20 MXQ20-20 MXQ20-30 MXQ20-30 MXQ20-10 MXQ20-20 MXQ20-30 MXQ20-50 MXQ20-50 MXQ20-50 MXQ20-75 MXQ20-40 0.12 MXQ20-40
0 5 10 15 20 25 Circulating fluid flow rate [L/min] Circulating fluid flow rate [L/min] HRR050-A-20, HRR050-W-20 0.5 Circulating fluid pressure [MPa] Outlet: 60 Hz 0.4 0.3 Outlet: 50 Hz Return port Return port (Option Z) 0.2 Allowable operating range 0.1 0 0 10 20 30 40 Circulating fluid flow rate [L/min] Required Facility Water Flow Rate 012 018 024 030 HRR -W HRR010-W-20 30 20 Facility
MXS6-30 MXS6-10 MXS6-40 MXS6-50 MXS6-40 MXS6-50 0.005 0.01 0.01 10 20 30 40 10 20 30 10 20 30 40 0 0 0 Load (N) Load (N) Load (N) 8 8 8 Lr=50 mm 0.020 0.04 0.05 MXS8-75 MXS8-50 MXS8-20 MXS8-10 MXS8-30 MXS8-40 MXS8-50 0.04 0.015 0.03 MXS8-40 MXS8-30 MXS8-40 MXS8-50 0.03 MXS8-75 MXS8-75 MXS8-30 MXS8-20 0.010 0.02 MXS8-20 MXS8-10 0.02 MXS8-10 0.005 0.01 0.01 20 40 60 80 20 40 60 0 0 0 20 40
(Unit: mm) A 2 2.5 4 5 5.5 10 B Model MXS 6 MXS 8 MXS12 MXS16 MXS20 MXS25 3 3.11-5 Air Slide Table Series MXS How to Order MXS 12 50 F9N S Air slide table Number of auto switches Bore size (Stroke mm) 2 1 n 6 8 12 16 20 25 10, 20, 30, 40, 50 10, 20, 30, 40, 50, 75 10, 20, 30, 40, 50, 75, 100 10, 20, 30, 40, 50, 75, 100, 125 10, 20, 30, 40, 50, 75, 100, 125, 150 10, 20, 30, 40, 50, 75, 100