Performance Performance data given in this chapter is based on an electrified plate (dimensions: 150 x 150 mm, electrostatic capacity: 20 pF) defined by ANSI standard (ANSI/ESD STM3.1-2006).
Cylinder Speed Chart Cv factor Metal seal (Rubber seal) Cylinder bore size mm Cylinder speed mm/s Model 40 50 63 80 100 125 140 160 150 300 1.5 (1.7) VQ7-6 450 600 750 150 300 3.2 (3.2) VQ7-8 450 600 750 Pressure 0.5MPa, Load factor 50% Note) Use as a guide for selection, as cylinder speeds will vary depending on the piping equipment.
Signal name 1 24 V 1 24 V (Control and input) (Control and input) 2 24 V (Output) 2 24 V (Output) 3 0 V (Control and input) 3 0 V (Control and input) 4 0 V (Output) 4 0 V (Output) 5 Not used (4) EX600-ED5-# PWR IN: M12 4-pin Plug A-coded PWR OUT: M12 5-pin Socket A-coded Configuration Pin No. Signal name Configuration Pin No.
Signal name 1 24 V 1 24 V (Control and input) (Control and input) 2 24 V (Output) 2 24 V (Output) 3 0 V (Control and input) 3 0 V (Control and input) 4 0 V (Output) 4 0 V (Output) 5 Not used (4) EX600-ED5-# PWR IN: M12 4-pin Plug A-coded PWR OUT: M12 5-pin Socket A-coded Configuration Pin No. Signal name Configuration Pin No.
/ sensors) 24 V (valves / loads) 0 V (valves / loads) FE 24 V (logic / sensors) 0 V (logic / sensors) 24 V (valves / loads) 0 V (valves / loads) FE BUS BUS Fig. 11-3 Block diagram of the EX245-DX1 74 No.EX##-OMY0004 12.
Socket 66101-2 24 pcs. Cable VCTF 24 cores x 0.75 mm2 Plug MIL standard type D connector Number of terminals: 25 pins Cable: 25 cores x 0.3 mm2 made by Tyco Electronics AMP K.K. VVZS3000-21A-8 20 m Option Option Cable Color List of Each Terminal No. Cable Color List of Each Terminal No. 3 5 7 Red 9 Blue 11 13 2 4 6 8 Red Yes 10 Blue Yes 12 1 Terminal no.
Rc 1 8 Rc 1 8 Rc 1 8 Rc 1 8 Rc 1 8 Rc 1 8 Rc 1 4 Rc 1 4 Rc 3 8 Rc 3 8 ZH05DS-06-01-06 ZH05DL-06-01-06 ZH07DS-06-01-06 ZH07DL-06-01-06 ZH10DS-06-01-08 ZH10DL-06-01-08 ZH13DS-08-02-10 ZH13DL-08-02-10 ZH15DS-10-03-12 ZH15DL-10-03-12 12.8 24 21 7.8 6 17 24 12.8 24 21 6 17 24 12.8 24 22 6 17 24 12.8 24 22 6 17 24 13.7 26 24.5 8 20 28 13.7 26 24.5 8 20 28 15.3 28 27 10 22 30 15.3 28 27 10 22 30
Signal name 1 24 V 1 24 V (Control and input) (Control and input) 2 24 V (Output) 2 24 V (Output) 3 0 V (Control and input) 3 0 V (Control and input) 4 0 V (Output) 4 0 V (Output) 5 Not used (4) EX600-ED5PWR IN: M12 4-pin Plug A code PWR OUT: M12 5-pin Socket A code Configuration Pin No. Signal name Configuration Pin No.
HRGC001--K HRGC002--K HRGC005--K Applicable model Contact input or PNP open collector input (voltage at OFF: 24 VDC; current at ON: 35 mA or less) External switch signal input External switch power output Power supply voltage 24 VDC 10% 5 W to 20 W Thermo-cooler side Customers equipment side 24 VDC 24 VDC 11 External switch power output Circuit configuration diagram 12 24 COM 13 24 VDC 24
JXC-OMT0062-A PRODUCT NAME CC-Link Direct Input Type Step Motor Controller (Servo / 24 VDC) MODEL / Series / Product Number LECPMJ Series Contents 1.
/50 m/s2 (2) (A) 4 (B) 2 VF IP65 (Dust/Splashproof type) 12 VDC, 24 VDC 15 to +10% of rated voltage Equivalent to Class B 1.8 W DC (75 mA) 1.8 W DC (150 mA) VFR 1 (P) 5 (R1) 3 (R2) Allowable voltage fluctuation Type of coil insulation Power consumption 24 VDC 12 VDC 3 position closed center VP4 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office
in Mounting AC40-06, AC40B-06 AC40C-06 AC50, AC55 AC60, AC50B AC55B, AC60B 46 44 24 66 19 If a T-interface is used on the IN side of the lubricator, lubricant may be mixed.
0.5MPa 0.5MPa Gripping force N Gripping force N 0.4MPa 0.4MPa 150 150 F 0.3MPa 0.3MPa 100 100 0.2MPa 0.2MPa 50 50 0.1MPa 0.1MPa 0 0 10 10 20 20 30 30 40 40 50 50 Gripping point L mm Gripping point L mm MHS2-50D MHS2-50D F 400 400 Internal gripping Pressure 0.6MPa Pressure 0.6MPa 300 300 Gripping force N 0.5MPa 0.5MPa Gripping force N 0.4MPa 0.4MPa 200 200 0.3MPa 0.3MPa 1N: Approx. 0.102kgf
EX245-DX1 8 x M12, 5-way sockets 8 x M12, 5-way sockets (0 to 7) (0 to 7) Short circuit Short circuit 24 V 24 V protection protection DI (n+1) DI (n+1) Sensor Sensor 0 V 0 V interface interface DI (n) DI (n) FE / Shield FE / Shield Input circuit / Input circuit / Bus interface Bus interface 24 V (logic / sensors) 0 V (logic / sensors) 24 V (valves / loads) 0 V (valves / loads) FE 24 V (logic
CN4: Counter Plug . 24 2 - 6.1 Counter plug specifications . 24 6.2 Counter plug wiring . 24 7.
MGQ 12, 16 M L 10, 20, 30, 40, 50, 75, 100 2020, 30, 40, 50, 75, 100 125, 150, 175, 200 Data MGQ 20, 25 M L M L MGQ 32, 40 50, 63 80, 100 25, 50, 75, 100, 125 150, 175, 200 OUT (N) IN (N) Theoretical Output (N) Bore size (mm) Operating pressure (MPa) Rod size (mm) Operating direction Piston area (mm2) 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Made to Order Specifications (For details, refer to
solid state switch input 30 msec or more PFMV PF2A 2 PNP outputs type PFM7--BPNP + Analog output type PFM7--EPNP + Analog output type PFM7--FPNP + External input type PFM7--HPF2W Brown DC (+) Brown DC (+) Brown DC (+) PF2D Main circuit Main circuit Main circuit Black OUT1 White External input Black OUT1 White Analog output Black OUT1 IF 24 VDC Load 24 VDC 24 VDC Load Load White OUT2 Load
: DL) M (Conduit terminal: T) K (DIN terminal: D) J (Conduit: C) I (Grommet: G) B (Air operated) VNA VNB SGC VNC 4 x 2 x 18 mounting hole VNH VND Applicable flange 1(A), 2(B) Pilot port 12(P1), 10(P2) A B C D E F G H I J K Note) L M Model VCC VNB5-32F VNB6-40F VNB7-50F 1 8 1 4 1 4 130 150 180 210.5 226 250 135 140 155 134 146 162.5 20 24 24 100 105 120 36 42 54 12 12 14 244 259.5 283.5 256.5
VDC 6 12 VDC How to Order Connector Assembly Positive common specifications For single solenoid: SX3000-23-1A For double solenoid, 3 position: SX3000-23-2A Negative common specifications For single solenoid: SX3000-24-1A For double solenoid, 3 position: SX3000-24-2A For detailed information on connector assembly, refer to page 1-6-9. 1-6-65 Flat Ribbon Cable Manifold Specifications Multiple