SMC Corporation of America
Elite Part Number Search
Search Results "ISE20A-T-P-01-JK"

3 3 01 07 X352 AS F 0 U Flow control With residual pressure relief valve (manual), G thread pilot port With pilot check valve Applicable tubing O.D.

F.R.L. combination VHS20 Y200-D Y200T-D AC20-D VHS30 Y300-D Y300T-D AC30-D VHS40 Y400-D Y400T-D AC40-D * New VHS series compatible with previous model spacer Y200(T)-A to Y400(T)-A. Spacer (Y-D) Spacer with bracket (YT-D) Pressure relief 3 port valve 8 - 5. Construction/ Parts list Standard specifications No.

KPQ/KPG Series Clean One-touch Fittings How to Order KP H 06 KP P 08 Q 01 KQ2 Applicable fitting size Clean One-touch fittings Made to Order KQB2 04 06 08 10 12 4 6 8 10 12 Specifications X53 With pipe tape Grease-free Symbol Q G KS KX Specifications (metal part materials) Brass (electroless nickel plated) Stainless steel 304 Rubber material: EPDM (Fluorine-coated) X193 Note 1) Gasket: M-

. / . 01$ 2 0 VXR239 2 0 17-3-53 2 The VX series will be revised shortly. Series VXR21/22/23 Normally Closed (N.C.)

(N.O.)3 3 B 1.VFR200 2.VFR210 P8 0.9Nm -10No.VFR2000-OMM0001 ) ARBF2000 P 1.0MPa 1) 0.05to0.83MPa 2) -5to60oC ()3) M5X0.8 (kg) 0.16 PA 5.5 (mm2) P1=0.7MPa,P2=0.5MPa S PB 5.1 DIN DIN DIN DIN / / / / AEA 12 (mm2) DIN 180 P2=0.5MPa S BEB 11 )0.9MPa ) )50oC )2 ) P A B -11 No.VFR2000-OMM0001 01C 01T COM A (A B B AB ) COM AB+ BVFR2100 A COM VFR2200 A COM B 3 400 5 A COM

Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: Female Thread, Lead Wire: w/o Lead Wire, Bracket: None, Operation Manual: w/o Operation Manual, Calibration Certificate

Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: M5 (Female Thread), Lead Wire: w/o Lead Wire, Bracket: None, Operation Manual: T (w/o Operation Manual, Calibration Certificate)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: R 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: None, Operation Manual: Operation Manual, Calibration Certificate

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: R 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: None, Operation Manual: Operation Manual, Calibration Certificate

Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: 01 (R 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: None, Operation Manual: K (Operation Manual, Calibration Certificate)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: 01 (R 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: None, Operation Manual: K (Operation Manual, Calibration Certificate)

(Vacuum Break Flow Adjustment Needle Round Lock Nut Type + Screwdriver Operation Type), Manifold Individual Supply: None, Manifold Common Release Pressure Supply: P (Manifold Common Release Pressure Supply Spec.)

(Vacuum Break Flow Adjustment Needle Round Lock Nut Type + Screwdriver Operation Type), Manifold Individual Supply: None, Manifold Common Release Pressure Supply: P (Manifold Common Release Pressure Supply Spec.), Exhaust Interference Prevention Valve: W (With Exhaust Interference Prevention Valve)

(Vacuum Break Flow Adjustment Needle Round Lock Nut Type + Screwdriver Operation Type), Manifold Individual Supply: None, Manifold Common Release Pressure Supply: P (Manifold Common Release Pressure Supply Spec.)

VNl VQ 1 (P) N.C. Note 5) DIN connector style: Applicable to dust and jet proof (IP65).

Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: None, Operation Manual: Operation Manual, Calibration Certificate

Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: None, Operation Manual: Operation Manual, Calibration Certificate

Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: None, Operation Manual: K (Operation Manual, Calibration Certificate)

Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: None, Operation Manual: K (Operation Manual, Calibration Certificate)

Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: None, Operation Manual: K (Operation Manual, Calibration Certificate)