:2009 EMC Directive 2004/108/EC EN61000-6-2:2005 EN55011:2009+A1:2010 Name and address of the person authorised to compile the technical file: Mr.
Dimensions/Socket (S) Male thread type A2 A1 T D H L1 L2 (mm) A1 A2 Effective area mm L2 Body size H Width across flats T Connection male thread Minimum bore Model D Weight g When When L1 connected connected KKH3S-01MS R1/8 33.5 20.4 20.4 6 36 18.2 14 1/8 40 37.5 KKH3S-02MS R1/4 31.5 19.5 21.1 9 34 KKH4S-01MS R1/8 54.1 50.4 46.4 48.8 22.9 6 50.1 KKH4S-02MS R1/4 54.7 51 19 45 45.4 38.9 9 48.7
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: NPT1/8, Lead Wire: w/o Lead Wire, Bracket: A1 [Bracket A, Vertical Mounting (ZS-46-A1)], Operation Manual: -
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: NPT1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: A1 [Bracket A, Vertical Mounting (ZS-46-A1)], Operation Manual: -
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: Female Thread, Lead Wire: w/o Lead Wire, Bracket: A1 [Bracket A, Vertical Mounting (ZS-46-A1)], Operation Manual: -
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: A1 [Bracket A, Vertical Mounting (ZS-46-A1)], Operation Manual:
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: NPT1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: A1 [Bracket A, Vertical Mounting (ZS-46-A1)], Operation Manual: w/o Operation
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: R1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: A1 [Bracket A, Vertical Mounting (ZS-46-A1)], Operation Manual: -
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: NPT1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: A1 [Bracket A, Vertical Mounting (ZS-46-A1)], Operation Manual: Operation
Rated Vacuum Range: -100.0 to 100.0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: NPT1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: A1 [Bracket A (ZS-46-A1)], Operation
Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: A1 [Bracket A (ZS-46-A1)], Operation
Rated Vacuum Range: -100.0 to 100.0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: A1 [Bracket A (ZS-46-A1
Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: R1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: A1 [Bracket A (ZS-46-A1)], Operation
Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: NPT1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: A1 [Bracket A (ZS-46-A1)], Operation
Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: 01 (R1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A1 [Bracket A (ZS-46-A1)], Operation
Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: w/o Lead Wire, Bracket: A1 [Bracket A (ZS-46-A1)]
2 (A) ] 0.5 [2 (A) 3 (R) ] bar) ) b 0.2 [1 (P) 2 (A) ] 0.15 [2 (A) 3 (R) ] Rc, NPT, G1/8 ON Delay 480g (*) 4 4 V R 2 1 1 0 01 01 Rc 1/8 N01 NPT 1/8 F01 F01 2 G 1/8 9 5 VR 1 ON Delay 0.560 () () 1 ON OFF 6 (1) 2 0.5MPa 2 10 (2) VR2110 3 )0.25MPa A 60sec (), (S) 0.8MPa 40sec B (3) (MPa) 3 OFF 1)4 1) OUT 0.7 0.6 VM1 VM1 () 0.5 0.4 0.3 0.2 ,0.6MPa VM2 VM2 0.1 ,0.3MPa 2
This is a legacy product, and replaced byZSE20-P-N01-L, SWITCH, VACUUM SERIES, ZSE30 VACUUM SWITCH, JD, ZSE30 1/8 PORTED, .19453 lb, ModelRated pressure rangeSet pressure rangeWithstand pressureMinimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--RepeatabilityHystere- sisAnalog outputDisplayDisplay accuracyIndicator lightEnviron- ment resistanceTemperature
This is a legacy product, and replaced byZSE20B-T-P-N01-W, SWITCH, VACUUM SERIES, ZSE40/50/60 VACUUM SWITCH, JD, ZSE40/50/60 1/8 PORTED, .47767 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay
This is a legacy product, and replaced byISE20A-T-P-N01-J, SWITCH, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, CB, ISE40/50/60 1/8 NPT VERSION, .24308 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay