Grommet AWG20 Insulator O.D. 2.5 mm q w Lead wire color q w Black Red There is no polarity. DIN terminal (Class B only) Since internal connections are as shown below for the DIN terminal, make connections to the power supply accordingly. 1: + () 3 + 1 2: (+) 2 Terminal no. 1 2 DIN terminal + () (+) There is no polarity.
W 3 port normally open SOL.C 7.
W Mounting orientation: Horizontal Operating pressure: 0.5 MPa Allowable Lateral Load at Rod End Standard Type: MQQTB Anti-lateral Load Type: MQQLB/Built-in Ball Bushing Type 60 5 50 4 Maximum allowable lateral load W (N) Maximum allowable lateral load W (N) 28 40 3 28 25 30 25 2 20 20 20 16 16 1 10 10 10 30 60 75 100 30 60 75 100 Stroke (mm) Stroke (mm) Note 1) The allowable lateral load
W Mounting orientation: Horizontal Operating pressure: 0.5 MPa Allowable Lateral Load at Rod End Standard Type: MQQTB Anti-lateral Load Type: MQQLB/Built-in Ball Bushing Type 60 5 50 4 Maximum allowable lateral load W (N) Maximum allowable lateral load W (N) 28 40 3 28 25 30 25 2 20 20 20 16 16 1 10 10 10 30 60 75 100 30 60 75 100 Stroke (mm) Stroke (mm) Note 1) The allowable lateral load
20 20 20 23 23 23 23 102 105 105 105 20 20 20 20 68.5 68.5 68.5 68.5 108 111 111 111 47.5 47.5 47.5 47.5 20 20 20 20 18 Series VXF2 Dimensions on the Mounting Side: Flange type VXF25B<<< VXF26B<<< 8 x M10 x 1.5 x 20 /C1 8 x M8 x 1.25 x 20 /C1 7 x 45o 7 x 45o 22.5o 22.5o A A A A 166p0.2 178p0.2 A-A A-A The surface roughness of the orifice machining should be Rz6.3 or less.
2 62 3-8H10 depth 20 Stroke + 32 92 Body mounting reference plane 90 (T-slot pitch) 3.3 20 5.8 67 1.7 5.3 62 T-slot 1 dimensions (Switch groove) 8-M6 x 1 thread depth 20 92 58 (88) 10 10 Stroke + 216 11.5 45 9.4 4.5 10 18 The body mounting reference plane should be used as a standard when mounting onto equipment.
(unit mm): When the current position is within W-AREA1 and W-AREA2, the WAREA output turns ON. When W-Area 1 < W-Area2, the Parameter ALM of alarm occurs.
38 L Hole: 12 +0.027 H8 0 30 30 17 17 20 20 15 15 2 x M6 thread depth 11 (for YA type) 2 x M6 thread depth 11 (for IA type) 35 15 18 2 x M6 thread depth 11 (for IA type) 2 x M6 thread depth 11 (for YA type) 20 20 20 20 57 40 17 17 A 19.5 0.2 0.5 25 15 45 45 60 60 Material: Cast iron Unit: mm Material: Cast iron Part no.
20, 25, 30, 35, 40, 45, 50, 75, 100 840 IN 1400 1960 63 63 936 OUT 1560 2184 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 1 The outline dimensions for 5 mm stroke will be the same as those for 10 mm stroke. 2 The outline dimensions for 10 mm stroke will be the same as those for 15 mm stroke.
(mm) 6 tube M14 x 1 ZX Rc 1/8 20 to 50 8 tube Ball joint rotation 15 ZR ZM Buffer Type ZH 10 to 16 20 to 50 ZU Pad dia.
Bore size 20, 25/MLGPM20/25 (Slide bearing) Operating Range as Stopper for MLGPM20/25 100 25 l = 50 mm l = 50 mm Weight of transferred object: m (kg) m m 20 5 10 10 20 30 40 50 Transfer speed: (m/min) Bore size 32 to 100/MLGPM32 to 100 (Slide bearing) Operating Range as Stopper for MLGPM32 to 100 1000 Weight of transferred object: m (kg) l = 50 mm l = 50 mm 100 m m 80 63 50 40 32 100
20 to 32 CNA Body length Manual unlocking bolt CNS LOCK Body length is the same as the standard MGP CLS Holding a clamped condition CLQ Locking direction is selectable MLGP Compact Guide Cylinder with Lock Series MLGP 20, 25, 32, 40, 50, 63, 80, 100 RLQ Extension locking Retraction locking W MLU LOCK ML1C A B B A DW -X Simple construction Simple and reliable locking type 20Data Four types
AR20K to AR60K A-A w A 2 OUT 1 I N C SM A w w Pressure in diaphragm chamber Inlet pressure (IN) Pressure in diaphragm chamber Inlet pressure (IN) r r IN OUT IN (Inlet pressure) OUT (Outlet pressure) q q e e Figure 1 Normal Figure 2 Backflow When the inlet pressure is higher than the regulating pressure, the check valve w closes and operates as a normal regulator (Figure 1).
Construction Meter-out type Meter-in type AS1200M AS2200M AS1210M AS2210M u w u w t e r !
Mini Free Mount Cylinder 4, 6, 8, 10, 12, 16, 20 : New additions Added 12, 16, 20 bore sizes.
For details, refer to pages 3-7-19 and 3-7-20.
As a rule when W + Pa>PA adjust P so that W + Pa = PA. (2) Installing a regulator with check valve at position (b) can decrease lurching during descent and actuation delay during ascent. As a rule adjust P so that W + PA = Pa.
W Mounting orientation: Horizontal Operating pressure: 0.5MPa Allowable Lateral Load at Rod End Standard type: MQQTB Lateral load resisting type: MQQLB/Built-in ball bushing 60 5 50 Maximum allowable lateral load W(N) Maximum allowable lateral load W(N) 4 28 40 3 28 25 30 25 2 20 20 20 16 16 1 10 10 10 30 60 75 100 30 60 75 100 Stroke (mm) Stroke (mm) Note 1) The indicated allowable lateral