95 J 25 30 30 41 50 50 70 70 B 58 94 101 116 128 129 169 176 K 28 34 34 40 54 54 66 66 C 11 26.5 28 31 36 36 43 46 L 30 44 44 46 54 56 65.8 65.8 D 25 57 55 59 68 68 87 87 M 4.5 5.4 5.4 6.5 8.5 8.5 11 11 E 26 65 64 66 74 74 84 84 N 6.5 15.4 15.4 8 10.5 10.5 13 13 F 29.5 28.5 30.5 35 35 44.5 44.5 P 40 55 55 53 70 70 90 90 G 0 2 Note) V 6 6 7 7 7 Q 2 2.3 2.3 2.3 2.3 2.3 3.2 3.2 S 18 25
95 A B 77 115 142 176 176 250 268 J 5.4 6.5 8.5 8.5 11 11 K 8.4 8 10.5 10.5 13 13 C 26 36 38 40 38 41 45 L 40 53 70 70 90 90 M 2.3 2.3 2.3 2.3 3.2 3.2 AL10 AL20 AL30 AL40 AL40-06 AL50 AL60 M5 x 0.8 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 1 25 40 53 70 75 90 95 Optional specification Metal bowl B 82 121 142 176 176 250 268 Model Metal bowl with level gauge B 162 196 196 270 288 Metal
Unit Configuration Examples XYZ axes YZ axes Xaxis Yaxis Zaxis 1 Triple Axis P&P Unit How to Order Combination LG 240Z A0 50 20 X L E G J ZB D C Y Axis type X X axis Stroke(mm) 100 10 Ball screw specifications Axis type Z axis Rolled ball screw(mm) 15, lead 20 900 1000 1100 1200 1300 1400 1500 Symbol C 90 A0 B0 C0 D0 E0 F0 Motor specifications Motor specifications Mitsubisi Electric Corporation
74.5 FLUID I N AIR EXH AIR EXH (pilot air exhaust port) 44.5 3 32 1/4 100 130 FLUID IN 3/8 PA5000 179 4-9 90 90 FLUID OUT 1/2, 3/4 AIR SUP (pilot air supply port) 1/4 (257) 112 56 165 56 Reset button RESET PROCESS PUMP FLUID OUT 167 AIR SUP 132.5 FLUID I N 125.5 103.5 AIR EXH 58.5 48.5 202 114 3.5 3 AIR EXH (pilot air exhaust port) FLUID IN 1/2, 3/4 1/4 5 Series PA3000/5000 Process Pump
74.5 FLUID I N AIR EXH AIR EXH (pilot air exhaust port) 44.5 3 32 Rc 1/4 100 130 FLUID IN Rc 3/8 PA5000 179 4-9 90 90 FLUID OUT Rc 1/2, 3/4 AIR SUP (pilot air supply port) Rc 1/4 (257) 112 56 165 56 Reset button RESET PROCESS PUMP FLUID OUT 167 AIR SUP 132.5 FLUID I N 125.5 103.5 AIR EXH 58.5 48.5 202 114 3.5 3 AIR EXH (pilot air exhaust port) FLUID IN Rc 1/2, 3/4 Rc 1/4 5 Process Pump
Union tee Male run tee P. 98 KFT Use to branch connection of tubes of both side 90 direction. P. 99 KFY Use to branch line in the same direction from female thread and in 90 direction. Branch tee Plug P. 98 KFT Use to branch line from female thread of both side 90 direction. P. 99 KFP Use to plug unused fitting. Swivel elbow KFV Use to pipe at right angle to female thread portion.
T VMG Union tee Male run tee Use to branch line in the same direction from female thread and in 90 direction. P. 50 KFT KFY P. 51 Use to connect tubes in both 90 directions. Male branch tee Plug KFT P. 51 KFP P. 50 Use to branch line from female thread in both 90 directions. Use to plug unused fittings. Swivel elbow KFV Use to pipe at right angles to female thread.
Never disassemble or modify the product, as this can cause loss of product functionality, and there is also a risk of electric shock and earth leakage. 2) Rotate the cartridge 90 degrees in the clockwise direction, and match the markings on the bar to those on the cartridge and secure. 1) Rotate the cartridge 90 degrees in the 1) Insert the cartridge into the bar so that the longer side of
230 1 1/2 Short 1.10 to 3.29 45 90 270 230 2 Middle 0.68 to 2.05 45 90 Component Parts IF33-10 500 420 2 1/2 Middle 0.74 to 2.30 80 160 Material No.
RH or less (No condensation) Storage temperature range 10C to 60C (No freezing) Storage humidity range 90% RH or less (No condensation) Insulation resistance Between all external terminals and the case: 50 MW (500 VDC) Weight 600 g (Screw mounting), 650 g (DIN rail mounting) *1 Do not use a power supply with inrush current protection for the motor drive power supply. *2 Power consumption
Then, insert the plug straight into the socket. 2 2 90 rotation Insert the plug completely until it stops. After connection, pull it gently to check that the plug does not come off. Rotate the sleeve by 90 degrees to match it to the locked position. Since detent is provided, the released position can be maintained.
100 110 120 0 10 20 30 40 50 60 70 80 90 100 110 120 130 Pump Circulating fluid Pump Circulating fluid head pressure head pressure Circulating fluid flow rate [L/min] Circulating fluid flow rate [L/min] [m] [MPa] [m] [MPa] HRL300-Am-20 (CH1) HRL100/200/300-Am-20 (CH2) 0.9 0.6 90 60 0.8 80 0.5 50 0.7 70 Circulating fluid outlet 0.6 0.4 60 40 Usable flow rate range Circulating fluid outlet
835.5 848 860.5 885.5 898 910.5 935.5 204 EX600 Integrated-type (For Input/Output) Serial Transmission System 10-SV Dimensions: Series 10-SV3000 Power supply with M12 connector Manual override Press and turn for the locking type 4(A) port side: Orange 2(B) port side: Green Light/surge voltage suppressor Marker groove End plate 4 x 5.3 (For mounting) L4 L5 Power connector L3 8 26 47 85.1 90
7 125.2 44 43 80.3 70 43.3 66 65.8 11 13 90 3.2 1 3.2 43.3 1/8 44.5 95 4.5 129.6 44 46 80.3 70 43.3 66 65.8 11 13 90 3.2 Note 1) The dimension of B is the length when the filter regulator knob is unlocked.
237.7 32 45 30 45 70 66 40.5 11 13 113 3.2 52.5 259.2 AFF60-D/AM60-D/AMD60-D 1 90 314.8 32 45 30 45 70 66 40.5 11 13 113 3.2 52.5 336.3 Specific Product Precautions Semi-standard specifications PC/PA bowl1 Stainless steel bowl2 Metal bowl1 Metal bowl with level gauge1 Element service indicator With barb fitting With drain guide With drain cock With drain guide With drain cock With drain
psig (0.0052 MPa) rise in delivery pressure per 100 psig (0.7 MPa) source pressure drop HF Cv Supply pressure effect Wetted Parts Material Flow Characteristics AK1000 3000 psig (20.7 MPa) 200 psig (1.4 MPa) Inlet pressure: B Brass S 316 SS SH Wetted Parts Body Poppet Diaphragm 100 0.69 Hastelloy C-22 Hastelloy C-22 PCTFE (Option: PEEK, PTFE) 316 SS 316 SS PCTFE (Option: Vespel, PEEK, PTFE) 90
66 17 10 218 80 22 10 218 80 19 10 241 90 25 10 241 90 21 10 277 100 30 10 334 150 40 13 13 16 16 19 19 22 22 32 100 63 113 76 119 76 145 90 151 90 166 106 173 106 200 122 253 160 8 12 6 40 66 84 28 5 2.0 27 37 1/4,3/8 172 AMH250 178 1/2 8 12 6 40 66 84 28 5 2.0 27 37 3/8, 1/2 204 AMH350 3/4 210 8 14 7 50 80 100 34 5 2.3 32 37 8 14 7 50 80 100 34 5 2.3 32 37 10 14 9 55 88 110 50 9 3.2 37
Caution Theoretical Cylinder Thrust 6, 10 15, 20, 25, 32, 40 50, 63 CY3B CY3R CY3B CY3R CY1S 63 63 1200 40 40 1100 3000 100 90 80 70 60 50 40 30 20 10 Theoretical thrust (holding force) (N) Theoretical thrust (holding force) (N) Theoretical thrust (holding force) (N) H CY1L Bore size 10 Bore size 2500 1000 900 800 700 10 50 50 H 32 32 2000 CY1H 1500 600 25 25 500 400 300 200 100 CY1F 1000
155 196 48 90 Supply pressure: 0.45 MPa 221 Body Ported Type Vacuum Ejector ZH Series Piping Variations Metric Inch One-touch connection SUP.
Dimensions ZP2-Z002 ZP2-Z003 40 20 0.1 0.2 A A 20 0.1 0.2 40 A A 20 40 A-A A-A w q q w 11 20 9 18 90 4 x 4 90 4 x 4 4 e e 5 5 () 12 () 4 x 2.4 1.8 1.5 4 x 2.4 1.5 0.9 20 9.4 Component Parts Component Parts Part no. Description No. ZP2-Z2A ZP2-Z2B ZP2-Z2C Material PTFE FKM Aluminum alloy Note Clear anodized Part no. Description No.