phase J 24-M3 x 0.5 A B C D t A COM COM COM B DC12V GND F.G.
AL A MM Width across flats NA K REC C0.1 8-J 4-FD M S + Stroke ZZ + Stroke H FX0.15 B CX CY Stroke range A Bore size (mm) AL B1 B C D FX FD FT GA GB H H1 I J K KA M MM NA P S ZZ 20 MQQ M Up to 200 18 15.5 13 50 16.5 8 36 5.5 6 18 12 35 5 31 M4 x 0.7 5 6 3 M8 x 1.25 29 1/8 83 124 25 Up to 300 22 19.5 17 50 18.5 10 36 5.5 6 18 12 40 6 33 M5 x 0.8 5.5 8 3.5 M10 x 1.25 29 1/8 83 129 32 RHC Up
AL A MM Width across flats NA K REC C0.1 8-J 4-FD M S + Stroke ZZ + Stroke H FX0.15 B CX CY Stroke range A Bore size (mm) AL B1 B C D FX FD FT GA GB H H1 I J K KA M MM NA P S ZZ 20 MQQ M Up to 200 18 15.5 13 50 16.5 8 36 5.5 6 18 12 35 5 31 M4 x 0.7 5 6 3 M8 x 1.25 29 1/8 83 124 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200
state switch HS A B D-F7V D-J79C D-F7WV D-F7BAVL D-A7 D-A80 D-A73C D-A80C D-A79W 32, 40 D-A7 D-A80 D-A73C D-A80C D-A79W D-F7V D-F7BAVL D-F7WV D-J79C Auto switch model A B Hs A B Hs A B Hs A B Hs A B Hs Symbol Standard Stroke Bore size (mm) 32 40 38.5 42 38 41.5 6.5 9 6.5 9 6 (6.5) 9.5 13.5 3.5 6 34 37.5 9.5 13.5 6.5 9 35 38.5 9 (9.5) 31.5 35 6.5 10.5 9.5 13.5 8.5 (9) 13 (13.5) Long Stroke
, 250, 320, 400, 500 40 800 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 Refer to page 6-13-20 for Minimum Stroke for Auto Switch Mounting. 50 1200 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 63 1200 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 80 1400 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 100 1500 25, 50, 80, 100, 125, 160, 200, 250
, 250, 320, 400, 500 40 800 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 Refer to page 6-13-20 for Minimum Stroke for Auto Switch Mounting. 50 1200 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 63 1200 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 80 1400 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 100 1500 25, 50, 80, 100, 125, 160, 200, 250
Note 1) Same as standard product except for cover assembly Note 2) 03, 04, and 06 indicate the relevant port sizes (Rc3/8, 1/2, 3/4). 108 108 AIR VENT M6 x P1 G1/2 AIR VENT M6 x P1 2 x RcD 2 x RcD C B A B OUT IN OUT IN C A DRAIN G1/4 DRAIN G1/4 (mm) (mm) A B D C A B D C Model Element length Model Element length A (L250) A (L250) 314 70 374 314 70 407 FGDC FGDE FGDC FGDE B (L500) B (L500)
Cylinder Speed Chart Bore size Series CS1/CS2 Pressure 0.5 MPa, Load factor 50% Cylinder stroke 300 mm Average velocity (mm/s) System 125 140 160 180 200 250 300 1000 Vertically upward movement Horizontal movement 900 800 700 600 500 400 300 200 100 0 A 800 900 1000 700 600 500 400 300 200 100 0 B 900 1000 800 700 600 500 400 300 200 100 0 C 800 900 1000 700 600 500 400 300 200 100 0 D 800
H 4 S y m b o l Initial power / Power consumption (W) 100 VAC 200/40 200/50 400/100 200 VAC 800/40 800/50 800/100 Heater assembly number XLA25-60S-1 XLA25-60S-2 XLA25-60S-2 XLA25-60S-3 No. of heater assemblies 1 pc. 1 pc. 1 pc. 1 pc.
Auto Switch Proper Mounting Position (Detection at Stroke End) Reed auto switch Solid state auto switch D-A9 D-M9 D-M9W Hs Hs 22 B A 24.5 B A A and B are the dimensions from the end of the head cover/rod cover to the end of the auto switch. A and B are the dimensions from the end of the head cover/rod cover to the end of the auto switch.
20 0.19 b 0.3 37 30 0.39 b 0.48 19 40 0.79 b 0.8 1.3 1 Compared with existing products (AFFmC, AMmC, and AMDmC series) 2 Compared with existing products (AMFmC series) 50 1.25 b 1.3 4 60 1.50 b 2.0 25 Color-identifiable elements This eliminates the accumulation of condensate.
V as an option) (Only 200 V as an option) Outdoor installation IPX4 HRSH Inverter type 0.1 5 to 35 (400 V as standard, 200 V as an option) (Only 200 V as an option) CH1 0.1 15 to 25 HRL Inverter dual type 26 kW Indoor use 19 kW 9 kW CH2 0.5 20 to 40 1.0 kW (Max. 1.5 kW) 322 Circulating Fluid Temperature Controller Thermo-chiller Dual Channel Refrigerated Thermo-chiller for Lasers HRL Series
0 100 200 300 400 500 0 0.2 0.1 0.3 0.4 0.6 0.5 0.8 0.7 0.9 300 0 100 200 1.0 VBA VBAT Flow rate (l /min (ANR)) Relief flow rate (l /min (ANR)) Supply pressure P1 (MPa) AP100 557 Series IR1000/2000/3000 Series IR2000 Flow Characteristics Relief Characteristics Pressure Characteristics Testing methods conform to JIS B 8372.
A to B C to D 500 L 5 to 500 -25 to 525 L/min 1000 L 10 to 1000 -50 to 1050 2000 L 20 to 2000 -100 to 2100 PF2MC7 40 to 4000 -200 to 4200 500 L 0.17 to 17.66 -0.90 to 18.50 cfm 1000 L 0.35 to 35.31 -1.80 to 37.10 2000 L 0.70 to 70.63 -3.50 to 74.20 The flow ranges and relationship between the fluid and PD are shown in the figures below.
Analog Output Flow/Analog output Output A B C Voltage output 1 V 1.1 V 5 V Current output 4 mA 4.4 mA 20 mA C Model Rated flow [L/min] Minimum Maximum LFE1 0.5 20 LFE2 2.5 100 LFE3 5 200 B A Outside the range 0 Min.
Trace the arrow mark from the point A at an ambient temperature 86F (30C) to obtain the intersection B on the curved line for the relative humidity 60%. 2. Trace the arrow mark from the intersection B to obtain the intersection D on the pressure characteristic line for 102psi (0.7 MPa). 3. Trace the arrow mark from the intersection D to obtain the intersection E. 4.
Bore stroke 32 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 450, 500 700 40 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 450, 500 800 50 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 450, 500, 600 1200 63 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 450, 500, 600 1200 80 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 450, 500, 600, 700, 800 1400 100 25, 50, 80, 100, 125, 160, 200,
Controller USB cable Communication 120.3 120.3 mm mm 200 200 mm/s mm/s (type A to mini-B) cable 100 500 100 500 1 1 200 1000 200 1000 2 2 50 200 50 200 3 3 CN3 PC (PC is prepared by the user.) 20 - 4.4 CN4: Counter connector (option) Connect the controller to the Multi-counter (CEU5) using the counter cable (LATH3-). Refer to section 6.2 Counter plug wiring (P.24).
200 300 300 0.4 MPa 0.4 MPa 150 150 0.3 MPa 0.3 MPa 200 200 0.3 MPa 0.3 MPa 100 100 0.2 MPa 0.2 MPa 0.2 MPa 0.2 MPa 100 100 50 50 0.1 MPa 0.1 MPa 0.1 MPa 0.1 MPa 50 100 150 200 0 0 50 100 150 200 0 40 80 120 160 200 0 40 80 120 160 200 Gripping point R (mm) Gripping point R (mm) Gripping point R (mm) Gripping point R (mm) 476 Parallel Style Air Gripper: Wide Type Series MHL2 Model Selection
B B B B B B RE A B 0 (0) 0 (0) 0 (2.5) 2 (6) 4 (7.5) 0 (0.5) 0 (0.5) 0 (3) 2.5 (6.5) 4.5 (8) 3.5 (6.5) 3.5 (6.5) 5.5 (9) 8.5 (12.5) 10.5 (14) 0 (2) 0 (2) 1 (4.5) 4 (8) 6 (9.5) 1 (4) 1 (4) 3 (6.5) 6 (10) 8 (11.5) 8.5 (11.5) 8.5 (11.5) 10.5 (14) 13.5 (17.5) 15.5 (19) 0.5 (3.5) 0.5 (3.5) 2.5 (6) 5.5 (9.5) 7.5 (11) 1 (0) 1 (0) 5.5 (1.5) 8.5 (4) 10.5 (6.5) 1.5 (0) 1.5 (0) 6 (2) 9 (4.5) 11 (7)