SMC Corporation of America
Elite Part Number Search
Search Results "CDLSF160-500-M9BWMAPC-DM9P"

Cylinder (Tube) Inner Diameter(φ): 160, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 160, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 160, Stroke(mm): 800, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Magnet: Built-in, Mounting: Front Flange, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 160mm, Thread: Rc, Stroke: 250mm, Option: Cushion at Both Ends, Cylinder Switch Type: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Pre-wired Connector: 3m Lead Wire, Number: 1 pc., Lock Unit Built-in Magnet: Built-in

Magnet: Built-in, Mounting: Front Flange, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 160mm, Thread: Rc, Stroke: 150mm, Option: Heat Resistant Tarpaulin Rod Boot & Cushion at Both Ends, Cylinder Switch Type: M9B--Solid State , Gen. Purpose, 2 Wire, Horizontal, 0.5M, Lead Wire or Pre-wired Connector: 0.5m Cord Length, M8-

Magnet: Built-in, Mounting: Front Flange, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 160mm, Thread: Rc, Stroke: 300mm, Option: Cushion at Both Ends, Cylinder Switch Type: M9B--Solid State , Gen. Purpose, 2 Wire, Horizontal, 0.5M, Lead Wire or Pre-wired Connector: 0.5m Cord Length, M12-4 Pin Connector, Number: 2 pcs. (Or

Magnet: Built-in, Mounting: Front Flange, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 160mm, Thread: Rc, Stroke: 1000mm, Option: Rear Cushion, Cylinder Switch Type: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 1 pc., Lock

Magnet: Built-in, Mounting: Front Flange, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 160mm, Thread: Rc, Stroke: 900mm, Option: Rear Cushion, Cylinder Switch Type: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 1 pc., Lock Unit

Magnet: Built-in, Mounting: Front Flange, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 160mm, Thread: Rc, Stroke: 350mm, Option: Cushion at Both Ends, Cylinder Switch Type: M9B--Solid State , Gen. Purpose, 2 Wire, Horizontal, 0.5M, Lead Wire or Pre-wired Connector: 3m Lead Wire, Number: 2 pcs. (Or None in the Case of No Switch

Magnet: Built-in, Mounting: Front Flange, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 160mm, Thread: Rc, Stroke: 250mm, Option: Cushion at Both Ends, Cylinder Switch Type: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire or Pre-wired Connector: 3m Lead Wire, Number: 2 pcs. (Or None in the Case of No Switch),

Magnet: Built-in, Mounting: Front Flange, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 160mm, Thread: Rc, Stroke: 300mm, Option: Cushion at Both Ends, Cylinder Switch Type: A54--Reed, DC Volt >5<24, AC Volt <200, LED, 0.5M, Lead Wire or Pre-wired Connector: 3m Lead Wire, Number: 2 pcs. (Or None in the Case of No Switch),

Magnet: Built-in, Mounting: Front Flange, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 160mm, Thread: Rc, Stroke: 100mm, Option: Cushion at Both Ends, Cylinder Switch Type: G39--Solid State, Gen. Purpose, 3 Wire PNP, Terminal, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 2 pcs

Magnet: Built-in, Mounting: Front Flange, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 160mm, Thread: Rc, Stroke: 300mm, Option: Cushion at Both Ends, Cylinder Switch Type: A54--Reed, DC Volt >5<24, AC Volt <200, LED, 0.5M, Lead Wire or Pre-wired Connector: 3m Lead Wire, Number: 2 pcs. (Or None in the Case of No Switch),

Magnet: Built-in, Mounting: Front Flange, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 160mm, Thread: Rc, Stroke: 300mm, Option: Cushion at Both Ends, Cylinder Switch Type: A54--Reed, DC Volt >5<24, AC Volt <200, LED, 0.5M, Lead Wire or Pre-wired Connector: 3m Lead Wire, Number: 2 pcs. (Or None in the Case of No Switch),

Magnet: Built-in, Mounting: Front Flange, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 160mm, Thread: Rc, Stroke: 250mm, Option: Cushion at Both Ends, Cylinder Switch Type: A54--Reed, DC Volt >5<24, AC Volt <200, LED, 0.5M, Lead Wire or Pre-wired Connector: 3m Lead Wire, Number: 2 pcs. (Or None in the Case of No Switch),

Magnet: Built-in, Mounting: Front Flange, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 160mm, Thread: Rc, Stroke: 250mm, Option: Cushion at Both Ends, Cylinder Switch Type: A54--Reed, DC Volt >5<24, AC Volt <200, LED, 0.5M, Lead Wire or Pre-wired Connector: 3m Lead Wire, Number: 2 pcs. (Or None in the Case of No Switch),

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, ROTARY, CLAMP, ACTUATOR, MKA/MKB CLAMP CYLINDER, IE, 25MM MKA/MKB DBL-ACT AUTO-SW, .88184 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, ROTARY, CLAMP, ACTUATOR, MKA/MKB CLAMP CYLINDER, HE, 20MM MKA/MKB DBL ACT-AUTO-SW, 1.10231 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, ROTARY ACTUATOR, AUTO-SW, ACTUATOR, CRQ2 ROTARY ACTUATOR, HE, 20MM CRQ2 DBL-ACT AUTO-SW, 1.77455 lb

Pilot: Internal Pilot, Pilot Valve Option: Standard, Coil Specification: Standard, Light/Surge Voltage Suppressor and Common Specifications: w/Light: None; Surge Voltage Suppressor: None; Common Specifications: Non-polarity, Auto Switch: B (2-wire), Cable Length: M (1.0 m), Connector Specifications: A (M8-3 Pin)