Series CJ2 miniature cylinders available in spring return, spring extend, or double acting offer stainless steel tubing and stainless steel rods. The series is available in bore sizes 6, 10, 16mm and stroke lengths from 1/2in. to 8in.. Mounting options include basic, foot, front flange, and double rear clevis. Series CJ2 is auto switch capable Standard double acting single rod, Bore sizes
(Or None in the Case of No Switch), Auto Switch Mounting Type: B (Band Mounting)
(Or None in the Case of No Switch), Auto Switch Mounting Type: B (Band Mounting)
(Or None in the Case of No Switch), Auto Switch Mounting Type: B (Band Mounting)
(Or None in the Case of No Switch), Auto Switch Mounting Type: B (Band Mounting)
(Or None in the Case of No Switch), Auto Switch Mounting Type: B (Band Mounting), Made to Order Option: XB9 (Low Speed Cylinder, 10 to 50mm/s)
(Or None in the Case of No Switch), Auto Switch Mounting Type: B (Band Mounting)
Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.), Auto Switch Mounting Type: B (Band Mounting)
Magnet: Built-in Magnet, Series: J2, Mounting: Single Foot, Bore Size: 10mm, Stroke A: 45mm, +: None, Stroke B: None, Cushion: Rubber Bumper, Head Cover Port Location: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs.
Magnet: Built-in Magnet, Series: J2, Mounting: Single Foot, Bore: 10mm, Stroke: 150mm, Cushion: Rubber Bumper, Head Cover Port Location: Perpendicular to Axis, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Type: Band
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: M9BW, Lead
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: M9B, Lead
Clean Series: Vacuum Suction Type, Magnet: Built-in Magnet, Series: J2, Mounting: Single Foot Style, Bore Size: 10mm, Stroke: 125mm, Cushion: Air Cushion, Head Cover Port Location: Perpendicular to Axis, Version: Z, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting
Clean Series: Vacuum Suction Type, Magnet: Built-in Magnet, Series: J2, Mounting: Single Foot Style, Bore Size: 10mm, Stroke: 125mm, Cushion: Air Cushion, Head Cover Port Location: Perpendicular to Axis, Version: Z, Auto Switch: M9NV--Solid State, Gen. Purpose, 3 Wire NPN, Vertical, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting
Clean Series: Relief Type, Magnet: Built-in Magnet, Series: J2, Mounting: Single Foot Style, Bore Size: 10mm, Stroke: 15mm, Cushion: Rubber Bumper, Standard, Head Cover Port Location: Axial Direction, Version: Z, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: M9BW, Lead
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: M9B, Lead
Magnet: D (Built-in Magnet), Series: J2, Mounting: B (Basic), Bore: 10mm, Stroke: 15mm, Cushion: Rubber Bumper, Head Cover Port Location: Perpendicular to Axis, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Type: B (Band Mounting)
Magnet: D (Built-in Magnet), Series: J2, Mounting: B (Basic), Bore: 16mm, Stroke: 15mm, Cushion: Rubber Bumper, Head Cover Port Location: Perpendicular to Axis, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Type: B (Band Mounting)
(Or None in the Case of No Switch), Auto Switch Mounting Type: B (Band Mounting)