SMC Corporation of America
Elite Part Number Search
Search Results "AVL2000-N02-5D-RZ-A"

Piping options: Side piping, Bottom piping A variety of actuator types.

Rc(PT) 12 04 o Bracket B o o Bracket o o @ L-bracket Connection NPTl/4 N02 a o Connection NPT3/8 N03 a o o tr 6 . 9 o u t = ^ O v o EL o Connection NPTl/2 N04 o Connection G(PD 1/4 F02 o o Connection G(PR 3/8 F03 o o Connection G(PR 1/2 F04 o O: Standard specifications O: Combination possible Blank: Combination not possible Modular Connection Part Numbers muxm : Air filter NAF3OOO NAF4OOO

Non inductive (A) Non inductive (A) Model Load Load resistance Light load Inductive load Motor load Load resistance Circuit Rated voltage (V) N.C.

Non inductive (A) Non inductive (A) IS3 10 Model Load Load resistance Light load Inductive load Motor load Load resistance IS3100 (Gasket piping) IS3000-02 (Rc 1/4 thread) Circuit Rated voltage (V) N.O.

Note 1) External pilot type Main valve: 0 to 0.9 MPa Pilot valve: 0.15 to 0.9 MPa Note 2) The standard body can not be retrofitted with a foot bracket. Model Actuator part no.

Option 1 G1/4 (M5 female threaded) Rc1/8 URJ1/4 TSJ1/4 Note) Fixed unit ISE80H: MPa Others : MPa, kPa With unit display switching function Fixed SI unit Note) F02 Nil C01 A2 B2 M P Initial value psi Option 2 Bottom ported R1/4 (M5 female threaded) None Nil 02L With bracket NPT1/4 (M5 female threaded) N02L A C01L A2L B2L Rc1/8 ZS-24-A ZS-35-A URJ1/4 Rear ported Bottom ported TSJ1/4 With bracket

2-Color Display (200 L type only) Digital Flow Switch Series PFMB7 RoHS How to Order PFMB7 201 C8 A M Type Calibration certificate Note 1) Integrated display 7 None With calibration certificate Nil A Rated flow range (Flow rate range) Note 1) Certificate in both English and Japanese Made to Order 2 to 200 L/min 201 Flow adjustment valve Unit specifications Nil S None Yes Unit selection function

75H 015 MPa 1 02 Rc1/4 N02 NPT1/4 S M12 (5m) F02 G1/4(ISO1179) L M12 (5m) 1 27 2 NPN 2 M SI 2 43 NPN 1 1 PNP 1 P psi() 1 65 PNP 1 1 2MPa 67 2 PNP 2 ZS-31-A A M12 (5 m) ZS-31-B S M12 (5 m) ZS-31-C L -8No.PS-OMH0002CN-D LCD () SET UP DOWN 4 24 ()OUT1ON LCD 4 UPON/OFF DOWNON/OFF SET -27-67 (-27-67 OUT2()) -9No.PS-OMH0002CN-D 7 7 "8"7 "-"()7 D Digit () 1 digit=0.01 MPa 0.01

Description Nil None 1 ISO 1179-1 compliant A Bracket A (Interchangeable with ISE70) Output specification1 Symbol Description B Bracket B L2 IO-Link: Switch output 1 + Switch output 2 (Switch output: NPN or PNP switching type) Option 1 1 Refer to pages 7 and 10 for details.

Non inductive (A) Non inductive (A) IS3 10 Model Load Load resistance Light load Inductive load Motor load Load resistance Circuit Rated voltage (V) N.C.

Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)

Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70), Operation Manual/Calibration Certificate: K (Operation Manual + Calibration

Pressure Range: ISE71 (0 to 1.6 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70

Pressure Range: ISE71 (0 to 1.6 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70), Operation Manual/Calibration Certificate: K (Operation Manual + Calibration

Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: A (Bracket A, Interchangeable with ISE70)

Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)

Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)

Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70), Operation

Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: A (Bracket A, Interchangeable with ISE70)